background image

SS-PCB50 

9

P

RODUCT

 S

PECIFICATIONS

INDOOR

AIR

CONDENSER AIR TEMPERATURE

23.9°C

29.4°C

35.0°C

40.6°C

46.1°C

L/S

WB

Total

Cap.

Sens
Cap.

Kw

Total

Cap.

Sens
Cap.

Kw

Total

Cap.

Sens
Cap.

Kw

Total

Cap.

Sens
Cap.

Kw

Total

Cap.

Sens
Cap.

Kw

2246

22.2

64.17

29.53

16.42

60.17

28.00

18.63

56.17

26.48

20.83

52.17

24.95

23.04

48.17

23.43

25.25

19.4

59.19

35.59

15.36

55.27

34.49

17.50

51.35

33.39

19.63

47.42

32.29

21.76

43.50

31.20

23.89

16.7

53.86

43.83

14.67

51.14

41.88

16.64

48.42

39.93

18.61

45.69

37.99

20.59

42.97

36.04

22.56

13.9

52.05

47.66

14.10

49.01

44.75

16.15

45.97

41.85

18.21

42.93

38.94

20.27

39.90

36.04

22.33

2643

22.2

66.90

32.71

16.97

62.61

31.14

19.21

58.31

29.56

21.45

54.01

27.99

23.68

49.71

26.42

25.92

19.4

61.40

41.82

15.87

57.44

40.10

18.05

53.48

38.39

20.22

49.53

36.68

22.40

45.57

34.96

24.57

16.7

56.02

51.22

14.77

52.89

48.26

17.00

49.76

45.30

19.23

46.63

42.34

21.46

43.50

39.38

23.68

13.9

56.02

51.22

14.77

52.89

48.26

17.00

49.76

45.30

19.23

46.63

42.34

21.46

43.50

39.38

23.68

3039

22.2

68.54

35.09

17.33

64.22

33.66

19.59

59.89

32.22

21.85

55.57

30.78

24.11

51.24

29.34

26.37

19.4

63.03

47.01

16.27

59.05

45.02

18.46

55.07

43.02

20.64

51.09

41.02

22.83

47.11

39.03

25.01

16.7

59.20

54.38

15.49

55.79

51.20

17.76

52.38

48.02

20.03

48.98

44.84

22.30

45.57

41.66

24.57

13.9

59.20

54.38

15.49

55.79

51.20

17.76

52.38

48.02

20.03

48.98

44.84

22.30

45.57

41.66

24.57

C

OOLING

 C

APACITY

 D

ATA

 (

CONT

.)

PCB120-5 (SI U

NITS

)

INDOOR

AIR

CONDENSER AIR TEMPERATURE

23.9°C

29.4°C

35.0°C

40.6°C

46.1°C

L/S

WB

Total

Cap.

Sens
Cap.

Kw

Total

Cap.

Sens
Cap.

Kw

Total

Cap.

Sens
Cap.

Kw

Total

Cap.

Sens
Cap.

Kw

Total

Cap.

Sens
Cap.

Kw

1605

22.2

43.67

21.02

9.95

41.04

19.52

11.27

38.41

18.03

12.59

35.78

16.54

13.91

33.15

15.04

15.23

19.4

40.29

25.44

9.31

37.70

24.09

10.59

35.11

22.74

11.86

32.52

21.38

13.14

29.93

20.03

14.41

16.7

36.65

31.24

8.89

34.88

29.22

10.07

33.11

27.19

11.25

31.34

25.17

12.43

29.57

23.14

13.61

13.9

35.42

33.85

8.54

33.43

31.17

9.78

31.44

28.49

11.01

29.45

25.82

12.24

27.45

23.14

13.47

1888

22.2

45.54

23.30

10.28

42.71

21.72

11.62

39.87

20.13

12.96

37.04

18.55

14.30

34.20

16.96

15.64

19.4

41.79

29.83

9.62

39.18

27.99

10.92

36.57

26.14

12.22

33.97

24.29

13.52

31.36

22.45

14.82

16.7

38.12

36.41

8.95

36.07

33.63

10.29

34.03

30.85

11.62

31.98

28.07

12.95

29.93

25.29

14.29

13.9

38.12

36.41

8.95

36.07

33.63

10.29

34.03

30.85

11.62

31.98

28.07

12.95

29.93

25.29

14.29

2170

22.2

46.65

25.03

10.50

43.81

23.49

11.85

40.96

21.94

13.20

38.11

20.39

14.55

35.26

18.84

15.90

19.4

42.90

33.53

9.86

40.28

31.41

11.17

37.66

29.29

12.48

35.04

27.18

13.78

32.41

25.06

15.09

16.7

40.29

38.65

9.39

38.05

35.67

10.75

35.82

32.70

12.11

33.59

29.72

13.46

31.36

26.75

14.82

13.9

40.29

38.65

9.39

38.05

35.67

10.75

35.82

32.70

12.11

33.59

29.72

13.46

31.36

26.75

14.82

PCB120-5 (E

NGLISH

 U

NITS

)

Sensible heat capacities shown are based on 26.7°C DB entering air at the evaporator coil. For sensible heat capacities at other 
than 26.7°C DB, deduct 44.32 W per 47 L/S of evaporator coil air for each degree below 26.7°C, or add 44.32 W per 47 L/S of 
evaporator coil air per degree above 26.7°C.

INDOOR

AIR

CONDENSER AIR TEMPERATURE

75°F

85°F

95°F

105°F

115°F

SCFM

WB

Total

Kbtuh

Sens

Kbtuh

Kw

Total

Kbtuh

Sens

Kbtuh

Kw

Total

Kbtuh

Sens

Kbtuh

Kw

Total

Kbtuh

Sens

Kbtuh

Kw

Total

Kbtuh

Sens

Kbtuh

Kw

3400

72

149.0

71.7

9.95

140.0

66.6

11.27

131.1

61.5

12.59

122.1

56.4

13.91

113.1

51.3

15.23

67

137.5

86.8

9.31

128.6

82.2

10.59

119.8

77.6

11.86

111.0

73.0

13.14

102.1

68.4

14.41

62

125.1

106.6

8.89

119.0

99.7

10.07

113.0

92.8

11.25

106.9

85.9

12.43

100.9

79.0

13.61

57

120.9

115.5

8.54

114.1

106.4

9.78

107.3

97.2

11.01

100.5

88.1

12.24

93.7

79.0

13.47

4000

72

155.4

79.5

10.28

145.7

74.1

11.62

136.1

68.7

12.96

126.4

63.3

14.30

116.7

57.9

15.64

67

142.6

101.8

9.62

133.7

95.5

10.92

124.8

89.2

12.22

115.9

82.9

13.52

107.0

76.6

14.82

62

130.1

124.2

8.95

123.1

114.7

10.29

116.1

105.3

11.62

109.1

95.8

12.95

102.1

86.3

14.29

57

130.1

124.2

8.95

123.1

114.7

10.29

116.1

105.3

11.62

109.1

95.8

12.95

102.1

86.3

14.29

4600

72

159.2

85.4

10.50

149.5

80.1

11.85

139.8

74.9

13.20

130.0

69.6

14.55

120.3

64.3

15.90

67

146.4

114.4

9.86

137.5

107.2

11.17

128.5

100.0

12.48

119.6

92.7

13.78

110.6

85.5

15.09

62

137.5

131.9

9.39

129.9

121.7

10.75

122.2

111.6

12.11

114.6

101.4

13.46

107.0

91.3

14.82

57

137.5

131.9

9.39

129.9

121.7

10.75

122.2

111.6

12.11

114.6

101.4

13.46

107.0

91.3

14.82

Sensible heat capacities shown are based on 80°F DB entering air at the evaporator coil. For sensible heat capacities at other 
than 80°F DB, deduct 84 BTU/h per 100 CFM of evaporator coil air for each degree below 80°F, or add 84 BTU/h per 100 CFM of 
evaporator coil air per degree above 80°F.

PCB180-5 (SI U

NITS

)

Sensible heat capacities shown are based on 26.7°C DB entering air at the evaporator coil. For sensible heat capacities at other 
than 26.7°C DB, deduct 44.32 W per 47 L/S of evaporator coil air for each degree below 26.7°C, or add 44.32 W per 47 L/S of 
evaporator coil air per degree above 26.7°C.

Summary of Contents for PCB090-5

Page 1: ...nized steel powder coated drain pan with 3 4 19mm NPT condensate connection Belt driven variable pitch sheave permits multi speed adjustment Centrifugal fan for quiet and efficient operation Filters 2...

Page 2: ...24 610 24 610 22 559 Motor Horsepower kW 1 2 0 37 1 2 0 37 1 2 0 37 Outdoor CFM Nominal L S 4300 2030 6100 2880 7000 3300 Condenser Coil Qty 1 1 1 Face Area Total Ft m 15 6 1 45 23 8 2 21 23 8 2 21 R...

Page 3: ...dimensions in inches and millimeters Drawings are not to scale Note The Horizontal Conversion Kit is required to convert a factory duct configuration downflow to a horizontal duct configuration as sho...

Page 4: ...265 13 1 7 3 19 6 10 9 26 2 14 6 5000 2360 12 6 7 0 18 8 10 4 25 2 14 0 5200 2454 12 1 6 7 18 1 10 1 24 2 13 4 5400 2548 11 6 6 4 17 4 9 7 23 3 12 9 5600 2643 11 2 6 2 16 8 9 3 22 5 12 5 5800 2737 10...

Page 5: ...1159 1 65 1259 1 87 1324 2 09 1384 2 31 Notes Selections in ITALICS require a field drive change See following table below for drive ranges Table includes all internal pressure drops including cabinet...

Page 6: ...8 1034 1 91 1105 2 26 1171 2 26 1233 2 99 3600 706 0 83 805 1 10 894 1 39 975 1 71 1051 2 05 1121 2 41 1188 2 78 1249 3 17 3800 733 0 95 829 1 23 916 1 53 995 1 85 1069 2 20 1139 2 57 1204 2 95 1266 3...

Page 7: ...08 2 12 1081 2 48 1150 2 86 1215 3 26 1277 3 68 1337 4 12 4600 874 1 63 957 1 97 1034 2 32 1105 2 69 1172 3 08 1236 3 49 1297 3 92 1356 4 37 4800 904 1 82 986 2 17 1060 2 54 1129 2 92 1195 3 32 1258 3...

Page 8: ...4 C 35 0 C 40 6 C 46 1 C L S WB Total Cap Sens Cap Kw Total Cap Sens Cap Kw Total Cap Sens Cap Kw Total Cap Sens Cap Kw Total Cap Sens Cap Kw 1203 22 2 32 77 15 48 8 36 30 67 14 52 9 29 28 56 13 56 1...

Page 9: ...22 2 46 65 25 03 10 50 43 81 23 49 11 85 40 96 21 94 13 20 38 11 20 39 14 55 35 26 18 84 15 90 19 4 42 90 33 53 9 86 40 28 31 41 11 17 37 66 29 29 12 48 35 04 27 18 13 78 32 41 25 06 15 09 16 7 40 29...

Page 10: ...2 191 1 174 8 14 77 180 5 164 7 17 00 169 8 154 6 19 23 159 1 144 5 21 46 148 4 134 4 23 68 57 191 1 174 8 14 77 180 5 164 7 17 00 169 8 154 6 19 23 159 1 144 5 21 46 148 4 134 4 23 68 6440 72 233 9 1...

Page 11: ...b for equipment in the down discharge application Curb includes provisions for duct attachment prior to setting unit Curb is shipped knocked down with all necessary hardware and gasket material MANUAL...

Page 12: ...every unit is run tested before it leaves the factory That s why we know there s no better quality Visit our website at www goodmanmfg com for information on Goodman Products Customer Services Parts...

Reviews: