If a wall mount installation is required, the installation
bracket should meet the requirement in the installation
bracket diagram and the wall should be able to support
the installation.
•
Be sure there are no obstacles blocking air discharge.
The installation wall should be constructed of brick, con-
crete or another surface of equal strength to hold the
unit safely. Make sure the connections to the wall,
bracket and unit are firmly seated and there are no ob-
structions to the airflow.
Anchoring the outdoor unit
The unit should be tightly anchored, horizontally, with a nut
and bolt ( 10 or 8) on a concrete or similarly rigid, stable
surface.
L2
L1
Figure 14
Outdoor
Unit Dimensions
Inches/mm (L1xHxW1)
L2 (mm)
L1 (mm)
MS*12*E15
31" x 21" x 10"
780 x 540 x 250
21.5"
549
11"
276
MS*18*E15
30" x 23" x 11"
760 x 590 x 285
21"
530
11.5"
290
MS*12*E19
30" x 23" x 11"
760 x 590 x 285
21"
530
11.5"
290
MS*18*E19
33" x 27.5" x 12.5"
840 x 700 x 320
22"
560
13"
335
Mounting Dimensions
Model
Drain joint installation
NOTE:
Drain joints differ slightly according to the different
outdoor units. Inspect your unit and use the installation in-
structions for your specific unit.
For drain joints with seals (Figure 15A):
•
Slide the seal onto the drain joint and insert into the
base pan hole of the outdoor unit. Rotate 90° to secure
(see Figure 16).
For drain joints without seals (Figure 15B):
•
Insert the drain joint into the base pan hole of the out-
door unit until it remains fixed, accompanied by a click-
ing sound.
NOTE:
For protection against water condensation off the out-
door unit during heating mode, connect the drain joint with an
extension drain hose (provided by the installer).
(Figure 15A)
(Figure 15B)
Correct alignment
Incorrect alignment
Figure 16