background image

P

rodUct

 S

PecificationS

P

rodUct

 S

PecificationS

SS-GPC14H

  

www.goodmanmfg.com 

19

w

iring

 d

iagram

Wiring

 is

 subject

 to

 change.

 Al

wa

ys

 

refer

 to

 the

 wiring

 diag

ram

 or

 the

 

unit

 for

 the

 most

 up-to-da

te

 wiring

.

    

W

arnin

G

High 

Voltage:

 Disconnect

 all

 power

 bef

or

ser

vicing

 or

 installing

 this

 unit.

 Multiple

 power

  

sour

ces

 ma

be

 pr

esent.

 F

ailur

to

 do

 so

 ma

cause

 pr

operty

 damage,

 per

sonal

 injur

y,

 or

 dea

th.














































T

HE
 G

O

O

DM

A


F

A

M

ILY
 O

F

C

O

MPAN

IES














®



































































































































































































































































































































































6s




































































2

3

NOTE #2

WH

NOTE #4

EM

TR

24V

208-240

3

CONTROL

240

208-240/1/60

SUPPLY VOLTAGE

C

COMP

C

S.A.

S

T1

R

L1

C

NOTE #4

H

F

RCCF

CM

T2

C

L2

BOX

H

RCCF

F

C

YL

BR

PU

2

24V

208

TR

C

BK

1

PU

COMP

CM

BR

BR

4

1

PLF

PU

BK

YL

S

BK

RD

BK

5

6

2

3

C R

LVJB

RD

BL

BR

WH

GR

YL

R

C

W2

W1

G

Y

A
T

O

T

S

M

R

E

H

T

T2

T1

RD

BL

NOTE #3

PU

BL

L1

GND

C

L2

PU

BK

60

/

/

1

0

4

2

-

8

0

2

7

8

9

BL

BR

208-240/1/60   0140G00407

RD

RD

BK

BK

RD

YL

C L G N

1 2 3

BL

BL

RD

RD

GR

GR

GR

EM

GR

SEE NOTE 2



1

L

3

1

2

R

W2

W1

Y

G

C

4

5

6

PLF

C

SEE NOTE #2

IF USED

THERMOSTAT

N

G

SEE UNIT RATING PLATE FOR TYPE AND SIZE

OF OVER CURRENT PROTECTION

COMPONENT LEGEND

C
CM
COMP
EM
GND
LVJB
PLF
RCCF

SA
TR

CONTACTOR
CONDENSER MOTOR
COMPRESSOR
EVAPORATOR MOTOR
EQUIPMENT GROUND
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER

WIRE CODE

BK     BLACK
BL     BLUE
BR     BROWN
GR     GREEN
OR     ORANGE
PU     PURPLE
RD     RED
WH     WHITE
YL     YELLOW

FACTORY WIRING

          LINE VOLTAGE
          LOW VOLTAGE
          OPTINAL HIGH
          VOLTAGE

FIELD WIRING

          HIGH VOLTAGE
          LOW VOLTAGE

NOTES:

1.   REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
      ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2.  TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW
     LEADS FROM EM "2" AND "3" TO "4" AND "5".  IF BOTH LEADS ARE
     ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3.  FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
     FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4.  START ASSIST FACTOR EQUIPED WHEN REQUIRED
5.  USE COPPER CONDUCTORS ONLY.
++  USE N.E.C. CLASS 2 WIRE

EM

1

C

2

3

SEE NOTE 5

YL

RD

SA
(IF USED) SEE NOTE 4

YL

WH

BK

PU

4 5

WH

WH

YL

BK





























































































Summary of Contents for GPC1424H41AC

Page 1: ...wder paint finish Fully insulated blower compartment with convenient access panels Louvered condenser coil protection One footprint three heights Complete warranty details available from your local de...

Page 2: ...Unit Major Revision Type Voltage Designator H Heat Pump 1 208 230 1 60 C Air Conditioner 3 208 230 3 60 4 460 3 60 Efficiency Refrigerant 13 13 SEER 15 15 SEER 2 R 22 14 14 SEER 16 16 SEER 4 R 410A No...

Page 3: ...Size NPT Refrigerant Charge oz 59 53 65 94 90 190 Condenser Fan Coil Horsepower RPM 1 6 815 1 6 815 830 1075 1075 1075 RLA LRA 1 1 1 7 1 1 1 7 1 5 3 0 1 4 2 9 1 4 2 9 1 4 2 9 Fan Diameter Fan Blades...

Page 4: ...7 0 78 0 59 0 38 0 89 0 80 0 61 0 39 0 92 0 83 0 62 0 40 0 96 0 86 0 65 0 42 0 97 0 86 0 65 0 42 T 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10 kW 1 48 1 51 1 56 1 61 1 60 1...

Page 5: ...424 448 467 LO PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167 85 920 MBh 25 4 25 9 27 1 28 9 24 8 25 3 26 5 28 2 24 2 24 7 25 8 27 6 23 6 24 1 25 2...

Page 6: ...78 0 59 0 38 0 90 0 80 0 61 0 39 0 92 0 83 0 63 0 40 0 96 0 86 0 65 0 42 0 97 0 87 0 65 0 42 T 19 18 14 10 19 18 15 10 19 18 15 10 20 18 15 10 19 18 15 10 18 17 14 9 kW 1 76 1 80 1 86 1 92 1 90 1 94 2...

Page 7: ...451 476 497 LO PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 152 129 137 150 160 134 142 155 165 85 1145 MBh 29 3 29 9 31 3 33 4 28 6 29 2 30 6 32 6 27 9 28 5 29 8 31 8 27 3 27 8 29 1...

Page 8: ...59 0 38 0 90 0 80 0 61 0 39 0 93 0 83 0 63 0 40 0 96 0 86 0 65 0 42 0 97 0 87 0 66 0 42 T 21 19 16 11 21 20 16 11 21 20 16 11 21 20 16 11 21 19 16 11 20 18 15 10 kW 2 39 2 44 2 52 2 60 2 58 2 63 2 72...

Page 9: ...450 475 495 LO PR 108 115 126 134 114 122 133 141 119 126 138 147 125 133 145 154 131 139 152 162 135 144 157 167 85 1350 MBh 37 7 38 5 40 3 43 0 36 9 37 6 39 4 42 0 36 0 36 7 38 4 41 0 35 1 35 8 37...

Page 10: ...0 58 0 37 0 87 0 78 0 59 0 38 0 90 0 81 0 61 0 39 0 93 0 84 0 63 0 41 0 94 0 84 0 64 0 41 T 21 20 16 11 22 20 16 11 22 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10 kW 2 70 2 76 2 85 2 94 2 91 2 97 3 0...

Page 11: ...460 486 506 LO PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 152 129 137 150 160 134 142 155 165 85 1432 MBh 41 9 42 7 44 7 47 7 40 9 41 7 43 7 46 6 40 0 40 7 42 7 45 5 39 0 39 7 41...

Page 12: ...0 60 0 39 0 91 0 81 0 61 0 39 0 94 0 84 0 63 0 41 0 97 0 87 0 66 0 42 0 98 0 88 0 66 0 43 T 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10 kW 2 42 2 48 2 58 2 68 2 65 2 72 2 8...

Page 13: ...443 468 488 LO PR 109 116 126 134 115 122 133 142 119 127 139 148 125 133 146 155 131 140 152 162 136 144 158 168 85 1777 MBh 48 6 49 5 51 9 55 3 47 4 48 4 50 7 54 0 46 3 47 2 49 4 52 8 45 2 46 1 48...

Page 14: ...57 0 37 0 86 0 77 0 58 0 38 0 89 0 80 0 60 0 39 0 92 0 83 0 63 0 40 0 93 0 83 0 63 0 41 T 24 22 18 12 24 22 18 13 24 22 18 13 24 22 18 13 24 22 18 12 22 21 17 12 kW 3 73 3 82 3 94 4 07 4 03 4 12 4 26...

Page 15: ...454 479 500 LO PR 106 112 123 131 112 119 130 138 116 123 135 143 122 130 141 151 128 136 148 158 132 140 153 163 85 1800 MBh 59 3 60 5 63 3 67 6 58 0 59 1 61 9 66 0 56 6 57 7 60 4 64 4 55 2 56 3 58...

Page 16: ...1053 Watts 162 175 187 201 213 221 T4 T5 230 CFM 1381 1325 1277 1233 1181 1144 Watts 195 203 217 233 247 258 GPC14 42H41 T1 230 CFM 1272 1197 1145 1106 1055 998 947 906 Watts 160 168 183 191 211 220 2...

Page 17: ...30 30 14 25 48 600 GPC1442H41 3 9 3 9 HKR 05 HKR 05C 25 27 30 30 4 75 16 200 HKR 08 HKR 08C 34 39 40 40 7 23 800 HKR 10 HKR 10C 46 52 60 60 9 5 32 400 HKR 15 HKR 15C 46 52 60 60 22 25 30 30 14 25 48 6...

Page 18: ...Specifications 18 www goodmanmfg com SS GPC14H Dimensions Minimal Clearances 34 075 66 25 A A Dimensions Model Chassis Size Height GPC1424 GPC1430 Small 30 GPC1436 GPC1442 Medium 35 GPC1448 GPC1460 L...

Page 19: ...EE NOTE 2 IF USED THERMOSTAT N G SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVER CURRENT PROTECTION COMPONENT LEGEND C CM COMP EM GND LVJB PLF RCCF SA TR CONTACTOR CONDENSER MOTOR COMPRESSOR EVAPORATO...

Page 20: ...Plenum Kit PCP101 103 PCP101 103 Downflow Plenum Kit R 8 PCP101 103 R8 PCP101 103 R8 Elbow Flashing w R 8 Liner PCEF101 103 PCEF101 103 Emergency Heat Relay OT EHR18 60 OT EHR18 60 External Horizonta...

Reviews: