PRODUCT DESIGN

For installaions in Canada, the GMH8 furnace is certified only to 4,500 ft.

* Negative pressure readings are in inches of water column (*w.c.)

MODEL

TRIP POINT

ID BLOWER

PRESSURE 

SWITCH

ID BLOWER

PRESSURE

SWITCH

PART # 

MODEL

TRIP POINT

ID BLOWER

PRESSURE 

SWITCH

ID BLOWER

PRESSURE

SWITCH

PART # 

GMH80453AN**

-0.60

B1370142

GMH80453AN**

-0.60

B1370142

GMH80703AN**

-0.60

B1370142

GMH80703AN**

-0.60

B1370142

GMH80704BN**

-0.60

B1370142

GMH80704BN**

-0.47

B1370176

GMH80903BN**

-0.60

B1370142

GMH80903BN**

-0.75

B1370179

GMH80904BN**

-0.60

B1370142

GMH80904BN**

-0.75

B1370179

GMH80905CN**

-0.70

B1370158

GMH80905CN**

-0.60

B1370142

GMH81155CN**

-0.70

B1370158

GMH81155CN**

-0.70

B1370158

GMH81405DN**

-0.75

013070159

GMH81405DN**

-0.60

013070142

PRESSURE SWITCH TRIP POINTS 

AND USAGE CHART

SQUARE NOSE

ROUND NOSE

PRESSURE SWITCH TRIP POINTS 

AND USAGE CHART

Part Number

B1370145

Open  Setting (°F) 

300

GMH80453AN**

2

GMH80703AN**

2

GMH80704BN**

2

GMH80903BN**

2

GMH80904BN**

2

GMH80905CN**

2

GMH81155CN**

2

GMH81405DN**

2

ROLLOUT LIMIT SWITCHES 

Part Number

B1370155

Open  Setting (°F) 

120

GMH80453AN**

1

GMH80703AN**

1

GMH80704BN**

1

GMH80903BN**

1

GMH80904BN**

1

GMH80905CN**

1

GMH81155CN**

1

GMH81405DN**

1

AUXILIARY LIMIT SWITCHES 

Part Number

B1370190 B1370187 B1370188 B1370198 B1370189

Open Setting (°F)

210

160

170

150

200

GMH80453AN**

1

---

---

---

---

GMH80703AN**

---

1

---

---

---

GMH80704BN**

---

---

1

---

---

GMH80903BN**

---

---

---

1

---

GMH80904BN**

---

---

1

---

---

GMH80905CN**

---

---

---

---

1

GMH81155CN**

---

---

---

1

---

GMH81405DN**

---

---

---

1

---

T.O.D. PRIMARY LIMIT

Summary of Contents for GMH80453AN Series

Page 1: ...or services performed by an unqualified person Refer to Service Manual RS6610004 for installation operation and troubleshooting information All safety information must be followed as provided in the...

Page 2: ...power before servicing or installing this unit Multiple power sources may be present Failure to do so may cause property damage personal injury or death Installation and repair of this unit should be...

Page 3: ...into this unit Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines These regulations may vary by jurisdiction Should questions arise conta...

Page 4: ...ombustion products An interlock switch prevents furnace operation if the blower door is not in place Keep the blower access door in place except for inspection and maintenance This furnace is also equ...

Page 5: ...es The kit will provide the proper design certified input rate within the specified altitude range 2000 3000 4000 4500 5000 6000 7000 8000 US BURNER ORIFICE 44 55 44 55 45 56 45 56 46 57 47 58 47 58 C...

Page 6: ...Draft Blower 11 Blower Door Interlock Switch 12 Integrated Control Module with fuse and diagnostic LED 13 Transformer 40 VA 14 Circulator Blower 15 Junction Box Pressure Switch Flue Pipe Connection C...

Page 7: ...PRODUCT DIMENSIONS 7 GMH8 UNITS A B GMH80453AN GMH80703AN 14 12 5 GMH80704BN GMH80903BN GMH80904BN 17 5 16 GMH80905CN GMH81155CN 21 19 5 GMH81405DN 24 5 23 All dimensions are in inches...

Page 8: ...5CN 0 60 B1370142 GMH81155CN 0 70 B1370158 GMH81155CN 0 70 B1370158 GMH81405DN 0 75 013070159 GMH81405DN 0 60 013070142 PRESSURE SWITCH TRIP POINTS AND USAGE CHART SQUARE NOSE ROUND NOSE PRESSURE SWIT...

Page 9: ...ights have an insulated Z bracket for use with one size smaller furnace All proper coil combinations are subject to being AHRI rated with a matched outdoor unit C A P F 1824 A 6 A PRODUCT TYPE C Indoo...

Page 10: ...m such as a central return Upflow Filters FURNACE INPUT FILTER SIZE TYPE 45M 160 in2 permanent 70M 241 in2 permanent 90M 320 in2 permanent 115M 400 in2 permanent 140M 370 in2 permanent 45M 320 in2 dis...

Page 11: ...lows Off On Mode 5 Min Fixed Auto Mode Dipswitch 2nd Stage Delay Dipswitch Note This furnace is designed to be used with a single stage room thermostat Start Start Call for Heat Call for Heat Safety C...

Page 12: ...000 80 000 96 000 A F U E 80 0 80 0 80 0 80 0 80 0 80 0 80 0 80 0 Rated External Static w c 0 20 0 50 0 20 0 50 0 20 0 50 0 20 0 50 0 20 0 50 0 20 0 50 0 20 0 50 0 20 0 50 Temperature Rise F 25 55 25...

Page 13: ...5 694 681 663 640 625 591 562 522 HIGH 4 0 2234 23 2151 24 2076 25 1990 26 1897 27 1803 1710 1569 GMH80704BN MED 3 5 1676 31 1653 31 1648 31 1581 33 1555 33 1492 1414 1 35 MEDIUM MED LO 3 0 1342 38 13...

Page 14: ...0 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULA...

Page 15: ...ST BE USED WHEN SERVICING 1 SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0 7 AMPS BLOWER PRIMARY LIMIT WH GR BK IGNITER SURFACE HOT PU RD 15 PIN PLUG C NO SWITCH PRESSURE BR SENSOR FLAME BK WH ROLLOUT L...

Page 16: ...CIR NEU K5 GAS VALVE HIGH LIMIT AUX LIMIT PRESSURE SWITCH FLAME SENSOR PROBE IGNITOR FP IGN GND MV MLV PS HLO HLI CIRCULATOR BLOWER XFMR HOT XFMR NEU 24 VAC TH RO1 RO2 R TR C Y G W COMPRESSOR CONTACTO...

Reviews: