2
www.goodmanmfg.com
SS-GMVM97
SS-GMVM97
www.goodmanmfg.com
3
Product Specifications
GMVM97
0603BNA
GMVM97
0803BNA
GMVM97
0804CNA
GMVM97
1005CNA
GMVM97
1205DNA
GCVM97
0603BNA
GCVM97
0803BNA
GCVM97
0804CNA
GCVM97
1005CNA
Heating Data
High Fire Input¹
60,000
80,000
80,000
100,000
120,000
60,000
80,000
80,000
100,000
High Fire Output¹
58,800
77,600
78,400
97,000
116,400
58,200
77,600
77,600
97,000
Low-Fire Steady-State Input¹
30,000
40,000
40,000
50,000
60,000
30,000
40,000
40,000
50,000
Low-Fire Steady-State Output¹
29,400
38,800
39,200
48,500
58,200
29,100
38,800
38,800
48,500
AFUE²
98
97
98
97
97
97
97
97
97
Temperature Rise Range (°F)
25 - 55
30 - 60
25 - 55
35 - 65
35 - 65
35 - 65
35 - 65
35 - 65
35 - 65
Vent Diameter³
2" - 3"
2" - 3"
2" - 3"
2" - 3"
2" - 3"
2" - 3"
2" - 3"
2" - 3"
2" - 3"
No. of Burners
3
4
4
5
6
3
4
4
5
Circulator Blower
Available AC @ 0.5" ESP
1.5 - 3
1.5 - 3
1.5 - 4
2 - 5
2 - 5
1.5 - 3
1.5 - 3
1.5 - 4
2 - 5
Size (D x W)
11" x 8"
11" x 8"
11" x 10"
11" x 10"
11" x 11"
11" x 8"
11" x 8"
11" x 10"
11" x 10"
Horsepower @ 1075 RPM
½
½
¾
1
1
½
½
¾
1
Speed
VS ECM
VS ECM
VS ECM
VS ECM
VS ECM
VS ECM
VS ECM
VS ECM
VS ECM
Electrical Data
Min. Circuit Ampacity⁴
8.8
8.8
11.6
15.4
15.4
8.8
8.8
11.6
15.4
Max. Overcurrent Device (amps)⁵
15
15
15
20
20
15
15
15
20
Shipping Weight (lbs)
118
121
142
144
157
117
122
144
146
¹
Natural Gas BTU/h
²
DOE AFUE based upon Isolated Combustion System (ICS)
³
Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon
furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or
3" diameter PVC.
⁴
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs
will require larger wire sizes.
⁵
Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
• Gas Service Connection ½" FPT
•
Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
•
For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.
•
For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum
clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.