Product Specifications

GMVM97 

0603BNA

GMVM97

0803BNA

GMVM97

0804CNA

GMVM97

1005CNA

GMVM97

1205DNA

GCVM97

0603BNA

GCVM97 

0803BNA

GCVM97

0804CNA

GCVM97

1005CNA

Heating Data

High Fire Input¹

60,000

80,000

80,000

100,000

120,000

60,000

80,000

80,000

100,000

High Fire Output¹

58,800

77,600

78,400

97,000

116,400

58,200

77,600

77,600

97,000

Low-Fire Steady-State Input¹

30,000

40,000

40,000

50,000

60,000

30,000

40,000

40,000

50,000

Low-Fire Steady-State Output¹

29,400

38,800

39,200

48,500

58,200

29,100

38,800

38,800

48,500

AFUE²

98

97

98

97

97

97

97

97

97

Temperature Rise Range (°F)

25 - 55

30 - 60

25 - 55

35 - 65

35 - 65

35 - 65

35 - 65

35 - 65

35 - 65

Vent Diameter³

2" - 3"

2" - 3"

2" - 3"

2" - 3"

2" - 3"

2" - 3"

2" - 3"

2" - 3"

2" - 3"

No. of Burners

3

4

4

5

6

3

4

4

5

Circulator Blower

Available AC @ 0.5" ESP

1.5 - 3

1.5 - 3

1.5 - 4

2 - 5

2 - 5

1.5 - 3

1.5 - 3

1.5 - 4

2 - 5

Size  (D x W)

11" x 8"

11" x 8"

11" x 10"

11" x 10"

11" x 11"

11" x 8"

11" x 8"

11" x 10"

11" x 10"

Horsepower @ 1075 RPM

½

½

¾

1    

1    

½

½

¾

1    

Speed

VS ECM

VS ECM

VS ECM

VS ECM

VS ECM

VS ECM

VS ECM

VS ECM

VS ECM

Electrical Data

Min. Circuit Ampacity⁴

8.8

8.8

11.6

15.4

15.4

8.8

8.8

11.6

15.4

Max. Overcurrent Device (amps)⁵

15

15

15

20

20

15

15

15

20

Shipping Weight (lbs)

118

121

142

144

157

117

122

144

146

¹ 

Natural Gas BTU/h

² 

DOE AFUE based upon Isolated Combustion System (ICS)

³ 

Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon 

furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 
3" diameter PVC.

⁴ 

Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs 

will require larger wire sizes.

⁵ 

Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes

•  All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•  Gas Service Connection ½" FPT
• 

Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.

• 

For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.

• 

For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum  

clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.

Summary of Contents for GCVM97

Page 1: ...icient and quiet variable speed airflow system gently ramps up or down according to heating or cooling demand Multiple continuous fan speed options offer quiet air circulation Auto Comfort and enhance...

Page 2: ...w Horizontal A Initial Release B 1st Revision Motor V Variable Speed ECM ComfortNet NOx E Multi Speed ECM N Low NOx S Single Speed Cabinet Width Gas Valve B 17 5 M Modulating C 21 C Two Stage D 24 5 S...

Page 3: ...on System ICS Installer must supply one or two PVC pipes one for combustion air optional and one for the flue outlet required Vent pipe must be either 2 or 3 in diameter depending upon furnace input n...

Page 4: ...C 5 9 19 23 24 31 A 21 2 14 23 1 1 28 2 1 2 2 2 6 1 26 23 Unfolded Flanges 22 Folded Flanges D Folded Flanges E Unfolded Flanges Air Discharge Side Cut out Side Cut Out Air Discharge LEFT SIDE VIEW FR...

Page 5: ...s Supply Location High Voltage Electrical Outlet Standard Drain Trap Connection PVC Left Side Exterior Drain Trap Holes Air Intake Pipe 2 PVC Vent Flue Pipe 2 PVC Alternate Gas Supply Location Alterna...

Page 6: ...rmal 1 316 55 Plus 10 887 594 Plus 10 1 448 50 C Minus 10 921 635 C Minus 10 1 250 57 Normal 1 023 705 Normal 1 389 52 Plus 10 1 125 776 Plus 10 1 528 47 D Minus 10 1 107 737 D Minus 10 1 256 57 Norma...

Page 7: ...djust High Stage CFM Rise F A Minus 10 780 492 A Minus 10 1 702 63 Normal 867 547 Normal 1 891 57 Plus 10 954 602 Plus 10 2 080 52 B Minus 10 1 044 748 B Minus 10 1 746 62 Normal 1 160 831 Normal 1 94...

Page 8: ...Cooling Speed 1 8 w c ESP GCVM970803BNA Heating Speed 1 5 w c ESP Rise Range 35 65 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Rise F A Minus 10 562 365 A Minus 10 950 n a Norm...

Page 9: ...Adjust High Stage CFM Rise F A Minus 10 706 472 A Minus 10 1 583 57 Normal 784 524 Normal 1 759 51 Plus 10 862 576 Plus 10 1 935 46 B Minus 10 970 670 B Minus 10 1 617 56 Normal 1 078 744 Normal 1 797...

Page 10: ...TU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 T...

Page 11: ...TO 60HZ 115 VAC 1 POWER SUPPLY WITH POWER BEFORE SERVICING WIRING TO UNIT MUST BE TO UNIT MUST BE PROPERLY POLARIZED EQUIPMENT GND FIELD SPLICE SWITCH TEMP SWITCH PRESSURE PROT DEVICE LOW VOLTAGE FIE...

Page 12: ...it 3 or 2 0170K00001S Flush Mount Vent Kit 2 AFE18 60A Fossil Fuel Dual Fuel Kit LPLP03 Low LP Gas Pressure Switch LPM 09 LP Conversion Kits Notes Indicates available for this model For installation i...

Reviews: