ACCESSORIES
10
SIDE WALL VENT KIT (0170K00000S)
V e rtical In sta lla tio n
H o riz o n ta l Insta lla tio n
This side wall only vent kit #0170K00000S is to be used
with 2” - 3” vent systems. This kit is
NOT intended
for use
with single pipe (indirect vent) installations.
The vent kit must terminate outside the structure and may
be installed with the intake and exhaust pipes located side-
by-side or with one pipe above the other.
See the section in this manual under "Vent Flue and Com-
bustion Air Pipe Terminations" for more information or con-
sult the Installation Instructions (IO-635).
SIDE WALL VENT KIT (0170K00001S)
This side wall only vent kit #0170K00001S is to be used
with 2” vent systems. This kit is
NOT intended
for use with
single pipe (indirect vent) installations.
Vent
Maintain 12" (18" for Canada)
minimum clearance above highest
anticipated snow level. Maximum of
24" above roof.
Combustion Air
Roof Boot/Flashing
(Field Supplied)
Support (Field Supplied)
45 Elbow
(Field Supplied)
Combustion Air
Vent
CONCENTRIC VENT CONVERSION KIT ( DCVK-20
DCVK-30)
DCVK
(Vertical Installation)
DCVK
(Horizontal Installation)
T
he DCVK-20 (2") or the DCVK-30 (3") is a concentric vent
kit approved with furnaces listed in this manual.
This concentric vent kit allows for vertical or horizontal vent
termination. The illustrations give a brief view of the kit and
its application.
Vent
Combustion Air
Flush to
1" maximum
45 Elbow
(Field Supplied)
Combustion Air
Vent
Strap
(Field Supplied)
EXTERNAL FILTER RACK (EFR01 )
Used on 96% Upflow Modulating Furnaces
BLOWER DECK
SCREWS
SLOTS IN FILTER
CLEAR SCREWS
ON UNIT
FRONT
OF UNIT
RETURN AIR
CUTOUT AREA
LOWER EDGE
SCREW
FILTER RACK ASSEMBLY
(FACE FILTER OPENING
TOWARDS FRONT
OF UNIT)
UNIT SIDE
PANEL
BASE
OF UNIT
See the section in this manual under "Vent Flue and Com-
bustion Air Pipe Terminations" for more information or con-
sult the Installation and Operating Instructions (IO-619*).
The vent kit must terminate outside the structure and may
be installed with the intake and exhaust pipes located side-
by-side or with one pipe above the other.
See the section in this manual under "Vent Flue and Com-
bustion Air Pipe Terminations" for more information or con-
sult the Installation Instructions (IO-805).