Summary of Contents for HPW-2600G

Page 1: ...tion 420 West Avenue Stamford CT 06902 203 359 4708 Sales 800 333 7467 Customer Service 800 370 2855 Fax 800 359 9625 E mail goodway goodway com Internet www goodway com Goodway is a trademark of Per...

Page 2: ...an electrical outlet as you risk severe shock and personal injury 10 Use only recommended No 1 or No 2 fuel oil in this unit Do not use gasoline crankcase draining or oil containing gasoline or solven...

Page 3: ...ight gauge which is located at the rear of the pump The oil level can also be checked using the dipstick which is attached to the oil filler cap Ensure that the vent hole in the cap dipstick is clear...

Page 4: ...TAILED BURNER START UP INSTRUCTIONS CAUTION DO NOT RUN THE FUEL PUMP DRY ALWAYS CHECK THE FUEL LEVEL IN THE TANK BEFORE RUNNING THE WASHER CHANGING PRESSURE The variable Unloader Valve is already set...

Page 5: ...burner when excess fuel has accumulated or when the furnace or boiler is full of vapor or when the combustion chamber is hot ADJUSTING THE BURNER NOTE The settings below have already been completed f...

Page 6: ...ll not operate THERMOSTAT The built in thermostat stops the unit from overheating Maximum temperature of the unit is 300 F 150 C Above this temperature the burner stops automatically THINGS TO CHECK R...

Page 7: ...seconds to get antifreeze into bypass line Shut off motor unit is now winterized TROUBLESHOOTING TROUBLE POSSIBLE CAUSE REMEDY Low Pressure Loose belt on pump Tighten belt Leaks in water system Tighte...

Page 8: ...see components pages Weak or no chemical at nozzle Air leak around soap siphon check valve and or metering valve leaking Tighten all fittings and tubing Pump motor heating or overloading Outlet orific...

Page 9: ...s Fuel nozzle interior loose Replace nozzle Water temperature too low Thermostat adjustment Adjust the thermostat to desired temperature Scale in coil De scale Improper combustion Readjust burner HPW...

Page 10: ...00 9531 2600 Coil Cap 9512 3500 9536 2600 Thermostat 9510 Axle Cap 9513 13 HP 3500 9538 6 5 HP 2600 Briggs Stratton Engine 9508 3500 9533 2600 Blow off valve 9518 Motor 9515 Fuel Solenoid 9516 Fuel Pu...

Page 11: ...9520 Hose 50 Ft Nozzles 9520 9521 Male Coupler 0 Pin Point QDN 0004R 3500 QDN 0003R 2600 15 Flat QDN 1504Y 3500 QDN 1503Y 2600 25 Flat QDN 2504G 3500 QDN 2503G 2600 QDN LP25 9527 Female Coupler 11...

Page 12: ...12 12...