- 1 -
- 2 -
- 3 -
english
Preparation
Fixture Installation
Bulb Replacement Instructions
Need Help?
DO NOT USE THIS FIXTURE WITH A DIMMING CIRCUIT.
If you presently have dimmer
controls, you will need to remove them and replace them with regular electrical switches.
If you have a three way dimmer, you will have to replace it with a regular three way
switch.
If you are unfamiliar with electrical installations, we recommend you have a qualified
electrician do your installation.
Important Safety Instructions
This light has a polarized plug (one blade is wider than the other) as a safety feature to
reduce the risk of electric shock. This plug will only fit in a polarized outlet one way. If the
plug does not fit, contact a qualified electrician. Never use with an extension cord unless
the plug can be fully inserted.
DO NOT ALTER THE PLUG.
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS. IMPORTANT SAFETY INSTRUCTIONS.
WARNING:
To reduce the risk of
FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS:
1. Turn off/unplug and allow to cool before replacing bulb (lamp).
2. Use only with a linear fluorescent bulb:
Bulb #F15T8/PL/AQ 15W (GLS9721P-GROW-I);
Bulb #F15T8 15W (GLS9721P-WH-I).
3. Handle bulb(s) with care during replacing. The glass tube of bulb is very fragile and
can break easily.
For Indoor Use ONLY. Not for use with aquariums. Do NOT mount near hight heat source,
or areas subjected to water, or water spray.
IMPORTANT:
Fluorescent bulbs are included with your Good Earth Lighting® fixture. In
order to protect the bulb during shipment, your bulb(s) may be packed in a separate area
of the packing materials. Additonally, your bulbs may already be placed into their
respective sockets, but may have a protective support collar slipped over the bulb. Do
NOT
operate you fixture with this support collar in place. You can either cut this collar off
or remove the bulb from the sockets and slide the support collar off the bulb. Discard the
support collar.
Before installation, plug fixture in to a 120V 60Hz electrical outlet to check for proper
operation. Then unplug and begin the installation.
SAVE THESE INSTRUCTIONS
DO NOT ATTEMPT TO INSTALL THIS LAMP WHILE IT IS PLUGGED IN. THIS LAMP IS FOR
INDOOR USE ONLY.
Troubleshooting Guide
Minor problems often can be fixed without the help of an electrician. Before doing any work
on the fixture, shut off power supply at the circuit breaker panel to avoid electrical shock.
Problem
Cause
Solution
Fixture doesn’t light
Bulb is defective
Replace bulb
Power is off
Check if power supply is on
Cleaning Instructions
Your fixture is made from quality materials that will last for many, many years with minimum care.
You may want to periodically clean the diffuser, or interior of the fixture using a mild, non-abrasive
glass cleaner and soft cloth. Do
NOT
use solvents, or cleaners containing abrasive agents. When
cleaning the inside of the fixture, make sure you have the power turned off, and do not spray liquid
cleaner directly onto the bulb, socket, ballast, or wiring.
In the event you are missing a part or have questions regarding installation
please visit our website at
www.goodearthlighting.com/support.html
or
call the Customer Care Center
1-800-291-8838
.
Model: GLS9721P-T8-WHI
GLS9721P-GROW-I
Modelo: GLS9721P-T8-WHI
GLS9721P-GROW-I
Good Earth Lighting
®
Under Cabinet Fluorescent Light Fixture
(Page 1)
Gabinete de luz fluorescente fijos
(Página 4)
Parts List/Lista de Partes
1 YEAR LIMITED WARRANTY
Good Earth Lighting, Inc. warrants this lighting fixture to be free from defects in materials
and workmanship for a period of one (1) year from the date of original purchase by the
consumer.
If you are missing any parts, or have any questions about your installation,
DO NOT
RETURN YOUR FIXTURE TO THE STORE! CALL US FIRST!
We can often help get the
problem corrected right over the phone. You can call us at
1-800-291-8838
, 9AM-5PM CST,
Monday through Friday.
In the unlikely event the Good Earth Lighting fixture fails to perform as it was designed to
do within one (1) year from date of purchase, we will repair or replace (at our option) the
unit in the original color, and style if available, or in a similar color and style if the original
item has been discontinued, without charge. This warranty covers the entire fixture,
EXCLUSIVE OF LAMPS
. Suspect units should be properly checked to ensure performance
problems are not lamp related. Defective units must be properly packed, and returned to
Good Earth Lighting, Inc. with a letter of explanation, and your original purchase receipt
showing date of purchase.
Call us at 1-800-291-8838
to obtain a Return Authorization
number, and an address where to ship your defective product.
Note: No C.O.D. shipments will be accepted. The liability of Good Earth Lighting, Inc. is in
any case limited to replacement of the defective light fixture product. Good Earth Lighting,
Inc. will not be liable for any other loss, damage, or injury which is caused by the product.
This limitation upon the liability of Good Earth Lighting, Inc. includes any loss, damage, or
injury which is (I) to person or property or otherwise; (II) incidental or consequential in
nature; (III) based upon theories of warranty, contact, negligence, strict liability, tort, or
otherwise; or (IV) directly, or indirectly related to the sale, use, or repair of the product.
Good Earth Lighting
®
Warranty
Printed in China
Place fixture up to mounting surface and mark position of
the narrow end of the keyslot holes on the mounting surface
with a pencil (
Fig. 3
). The screw hole locations must be
exact for the fixture to mount properly.
1
2
3
4
7
Remove diffuser by pressing in the sides of diffuser at the
tabs and lifting up (
Fig. 1
).
6
Replace diffuser by aligning pins with the slots pressing in
the sides of diffuser at the tabs and pushing up until the pins
lock in place (
Fig. 7
).
Once the fixture is in place, route your power cord to the closest outlet. Plug it in and
turn on power switch.
Remove the bulb from the fixture by placing your thumbs on
the metal ends of the bulb. While applying slight pressure on
the bulb, roll the bulb toward you until the contact pins on
the ends of the bulb disengage from the socket. Pull the bulb
straight out from the socket and set aside during mounting
(
Fig. 2
). Handle bulb with care during replacing. Glass tube of
bulb is very fragile and can break easily.
5
Drill a 1/16 in. pilot hole into the marked screw locations. You
can also use an awl or nail to dimple the screw holes. Start
the screws, but do not tighten fully. Slide the fixture over
until the narrow legs of the keyhole slots are under the
heads of the screws (
Fig. 4
). Finish tightening the screws
until they are firmly seated and the fixture is tightly secured
to the mounting surface.
Install the bulb into the sockets by aligning the pins of the
bulb with the slot in the sockets (
Fig. 5
). Using your thumbs
and forefinger, press the metal ends of the bulb socket and
roll the bulb forward until it rotates 90 degrees inside the
socket, making contact between the bulb pins and the
socket contacts (
Fig. 6
).
Replace only with linear fluorescent bulb:
Bulb #F15T8/PL/AQ 15W (GLS9721P-GROW-I);
Bulb #F15T8 15W (GLS9721P-WH-I).
Do not replace with any other wattage of linear
fluorescent bulb. These bulbs are readily available at your local home center and most
larger hardware stores.
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 5
5
4
Replace diffuser by aligning pins with the slots pressing in
the sides of diffuser at the tabs and pushing up until the pins
lock in place (
Fig. 5
).
Restore power to the fixture.
3
Install the bulb into the sockets by aligning the pins of the
bulb with the slot in the sockets (
Fig. 3
). Using your thumbs
and forefinger, press the metal ends of the bulb socket and
roll the bulb forward until it rotates 90 degrees inside the
socket, making contact between the bulb pins and the
socket contacts (
Fig. 4
).
Fig. 3
Fig. 4
Fig. 1
Fig. 2
1
2
Remove diffuser by pressing in the sides of diffuser at the
tabs and lifting up (
Fig. 1
).
Remove the bulb from the fixture by placing your thumbs on
the metal ends of the bulb. While applying slight pressure on
the bulb, roll the bulb toward you until the contact pins on
the ends of the bulb disengage from the socket. Pull the bulb
straight out from the socket and dispose of properly (
Fig. 2
).
Fig. 1
Fig. 2
Fig. 3
Good Earth Lighting, Inc., 5260 Capitol Drive, Wheeling, IL 60090
©2007 Good Earth Lighting, Inc.
Rev. 11/07 INS9721
Hardware Kit
*Actual hardware kit may
differ from illustration
Juego de tornillería
*La tornillería real puede
diferir de la que se
muestra en la ilustración
Diffuser
Difusor
Cord
Cordón eléctrico
Switch
Interruptor
Bulb