Specification

9

Equipment Class

Model:

Trade name:

Power supply:

Safety:

EMC (Electro-Magnetic Compliance):

Protection from electric shock:

Protection from ingress of liquids:

AL-DFA20

Dr’s Finder Neo

3.7V Lithium-polymer

IEC60601-1

IEC60601-2

Type BF

IXPO (ordinary equipment)

Operation, transport, and storage condition for the main unit

Operation conditions

Ambient temperature range:

Relative humidity:

Atmospheric pressure range:

+10C ~ +40C / 50F ~ 104F

30 ~ 80 RH% without condensation

800 ~ 1060 hPa

Additional Information

Main unit

Approx. 43 x 46 x 16 mm / Approx. 24 g

Measurement

Measurement

File hook

Approx. 200 mm (included hook tip)

Length

Lip hook

Approx. 65 mm / Approx. 2.15 mm

Length / Dia.

Probe cord

Approx. 70 cm

Length

Length

Extension cord

Approx. 60 cm

Stand

Approx. 43 x 67 x 62 mm / Approx. 52 g

Symbol

This device conforms with the European Directive, 93 / 42 / EEC which
includes the requirements for electromagnetic compatibility

Attention,
consult accompanying documents.

SN

Serial number
oo oo oo oooo
Model / Month / Year / Serial

This symbol is appixed to fulfill the requirements of EU Directive 2012/19/EU
Article 11. This equipment cannot be disposed of as unsorted municipal
waste within the European Union. Follow local regulations for disposal.

Summary of Contents for AL-DFA20

Page 1: ...User manual Eng Apex Locator N e w C o n c e p t o f A p e x L o c a t o r Model AL DFA20 Be Smart Be Compact...

Page 2: ...6 How to use 14 7 Maintenance 21 8 Trouble Shooting 22 9 Specification 25 10 Accessories 25 11 Warranty 25 12 Warranty card 26 2 Safety Information 03 Warning and caution Notes and reference Installat...

Page 3: ...es 02 Be Smart Be Compact Thank you for purchasing the device The instructions described below have been designed to provide the necessary information for the successful operation maintenance and safe...

Page 4: ...h Indicates a potentially hazardous situation which if not avoided may result in minor moderate injury or in damage of property Caution Warning Warning and caution used in this manual are shown below...

Page 5: ...ave the unit in areas of high temperature or exposed to direct sunlight internal circuit defect may cause overheat or fire Securely connect the dust free power plug to the outlet Use this device venti...

Page 6: ...ape and condition of the tooth as well as a decline in the equipment s performance Do not use damaged accessories file hook probe cord or etc An accurate measurement can not be made with damaged acces...

Page 7: ...wash it off with copious amount water to avoid skin damage Turn off the device when don t use it Do not use this product for any purpose other than dental use This device is not water prove Be carefu...

Page 8: ...nt as soon as the file is inserted into the root canal but it will return to normal as the file is advanced down towards the apex The lip hook could cause an adverse reaction if the patient has an all...

Page 9: ...n Do not disassemble or overhaul the device Unusual performance may cause injuries electric shock fire or malfunction Be careful from any liquid when cleaning Do not use solvent containing orange oil...

Page 10: ...ease check the contents described below when removing the contents from the original packaging Main body Charging cable Probe cord extension cord File hook x 2 ea Lip hook x 3 ea User Manual Ruler x 2...

Page 11: ...Be Smart Be Compact Parts identification 4 10 Probe jack Charging port Touch screen Charging cable Calibration jig Stand Power button Probe cord extension cord File hook Lip hook Ruler Clip...

Page 12: ...ug is securely plugged into the probe jack A poor connection can prevent measurement Do not drop anything on or bang the probe cord plug after it has been inserted into the probe jack Note Insert file...

Page 13: ...the file hook and lip hook are properly connected to the probe cord Then Touch metal part of the file hook with the lip hook Check that all the meter bars on the display light up Check the device oper...

Page 14: ...3 Working length setting 13 Installation 5 Drag the screen on upper side to go setting mode Set the working length on the setting mode Adjust working length by click or icon 0 3 0 3 DRAG 3 DRAG...

Page 15: ...On charging Full charged Need to charge If the battery voltage is too low the device turns off with LOW BATTERY message Sound indicator W L S point Measured figure Meter W L S indicator Sound indicato...

Page 16: ...he device on 2 Hook the lip hook in the corner of the patient s mouth 3 Clip the file hook to the metal shaft of the file Press in direction of arrow with the thumb Clip the file Release thumb File ho...

Page 17: ...will differ somewhat depending on each individual tooth This discrepancy must be judged by the dentist as he works on the tooth How to use 6 Make sure to take x ray to check the results The beep sound...

Page 18: ...ip the connectors to connect and disconnect cords Do not wrap the probe cord around the body of the main unit GOOD BAD Connect charging cable micro USB to device And connect the charging cable 4 Charg...

Page 19: ...e will be turn off to save electric power Reference 1 Display style There are 3 display style Drag by finger to left or right 6 Functions 2 Sound on off Click the sound indicator by finger Sound on So...

Page 20: ...Drag the display from up to bottom as follow image by finger To back drag the display to up again Click Min or Sec Then adjust the time by click icon 8 Timer mode Reset Start 01 00 Click and hold the...

Page 21: ...rate Connect the calibration jig on the probe jack And turn on the device Check the measured figure shows 2 9 Calibration If the figure doesn t show 2 9 from the accurate check need to calibrate as fo...

Page 22: ...ation pouch Minimum drying time after sterilization 10 minutes Do not sterilize in any way other than autoclave Autoclave and dry at 121 but do not exceed that temperature The file hook and lip hook m...

Page 23: ...hook making good contract with oral mucosa Is the file hook dirty Make sure the lip hook makes good contact with the oral mucosa Clean the file hook Measured figure overreacts or is too sensitive Meas...

Page 24: ...caries infected area to the gums and prevent and accurate measurement from being made The meter bar may jump to APEX when it reaches the opening of a lateral canal of the opening of a fractured tooth...

Page 25: ...on Main unit Approx 43 x 46 x 16 mm Approx 24 g Measurement Measurement File hook Approx 200 mm included hook tip Length Lip hook Approx 65 mm Approx 2 15 mm Length Dia Probe cord Approx 70 cm Length...

Page 26: ...rchase the repair will be free of charge However repair of accessories File hook Lip hook Probe cord batteries or transportation costs are not covered by the warranty For more information refer to the...

Page 27: ...al disaster such as fire earthquake and flood etc Malfunction and damage according to user s intention or accident Malfunction and damage according to using incompaible product 3 The manufacturer does...

Page 28: ...2017 Address 208 B dong 283 Bupyeong daero Bupyeong gu Woolim Lions Valley Cheongchoen dong Incheon 21315 Republic of Korea Tel 82 32 424 6325 Fax 82 32 424 6326 Website www gooddrs com E mail good go...

Reviews: