background image

Beispiel: 

30646/30641

                30647/30642

Beispiel: 

30648/30643

               30649/30644

Beispiel: 

30645/30640

Beispiel: 

30778/30780

               30779/30781

Sample:  

30646/30641

 

30647/30642

Sample:  

30648/30643

 

30649/30644

Sample:  

30645/30640

 

Sample:  

30778/30780

 

30779/30781

2/4

 

User‘s manual for 

 

LED Flood Lights

 

Articles: 3030640-30649

Pillmannstraße 12 | 38112 Braunschweig | Germany

Revision Date: 2014-06-03 | Version 1.3 | 

Subject to change.

Read this user‘s manual completely and carefully. It is part of the product and contains important notes for operating. Keep this docu-

ment for other users or for personal reference. The lamp must not be changed electrically.

Safety Instructions

  Risk of life by electric shock!

>> The necessary electrical knowledge can be found in the accompanying VDE notes.

>> Place, install and transport product, product parts and accessories in safe way.

>> Avoid vibration and mechanical pressure.
>> Only use products, product parts and accessories that are in perfect condition.

>> Make sure that the product is installed before plugging in.

>> Do not cover the lamp by any object.

>> Do not use the lamp under sealed ambient conditions.
>> In the case of changes to the product, we reserve the right to inform the customer in advance.
>> The terminal to be used must be in accordance with EN 60998-2-1 or EN 60998-2-2;

 

- Type of terminals: Screw / screwless terminals;

 

- Number of terminals: 3 Pole

 

- Rated voltage : 240 V min;

 

- Rated connection capacity: min 1.0 mm

2

;

 

- Any necessary preparation of the cable ends: The length of exposed conductor ends shall be not longer than 8 mm;

 

- Fixing method: Fixed inside the connecting box.

 

- Mounting method: Fixed in the connection box.

>> Switch off the lamp before touching and let it cool down.

>> Dispose broken glass with suitable protective measures.

>> Let at least 1m safety distance to illuminated materials.

Description and Function 

 

 

Your product is a LED Fluood Light, replaces conventional Halogen lamps and is made to illuminate things, rooms or outdoor areas. It can be mounted to horizontal or 

vertical surfaces. 

 

The product is not dimmable.

IP 65 

The product is protected against dust entry and water jet. 

 

The product that the product is conformed to the basic European standards and directives. 

Intended Use

Only use the product as described in chapter “Description and Function“. Other use is not permitted. Misuse leads to loss of warranty and axclusion of liability.

Mount the LED Flood Light

 

1.8-6.0m

  

1. 

Check the packing content for integrity.

 

 

2. 

Choose a suitable and safe mounting place.

 

 

3. 

Select the mounting material according the choosed surface material.

 

 

 

 

 

Mounting material is not included.

 

 

 

 

 

4. 

Mark the mounting hole positions by mounting bracket and pencil.

 

 

5. 

Drill the mounting holes with suitable tool.  

 

 

 

6. 

Attach the LED Flood Light with your mounting material. 

Install the LED Flood Light

1.0mm²
1.0mm²
1.0mm²

 1. 

Switch off the fuse and check the absence of voltage.

 

 

2. 

Put the cable ends of the LED Flood Light in the terminal, that each cable color of the 

 

 

 

LED Flood Light is connected with the same color of the mains connection.

 

 

3. 

Fix the cable connections by screwdriver.

Article Number Operating 

voltage

Power con

sumption

Nominal 

Beam 

angle

Light color / 

Color temperature Life time

Protection 

level

Installation 

height

Dimensions / Weight

warm white / 3000K

cool white / 6000K

Maintenance and Care

The product is maintenance-free.  >>  

Only use a dry or a slightly with water moistened cloth for cleaning.

 

 

 

>>  

Do not use any detergents nor chemicals.

Disposal Instructions

According to the European WEEE directive, electrical and electronic equipment must not be disposed with consumers waste. Its components must be recycled or 

disposed apart from each other. Otherwise contaminative and hazardous substances can pollute our environment. As a consumer, you are committed by law to 

dispose electrical and electronic devices to the producer, the dealer, or public collecting points at the end of the devices lifetime for free. Particulars are regulated in 

national right. The symbol on the product, in the user`s manual, or at the packaging alludes to these terms. With this kind of waste separation, application, and waste 

disposal of used devices you achieve an important share to environmental protection. 

-

-

-

30640

100-240V~ 

50/60Hz

max. 70W

4900lm

120°

>45000h

IP65

1.8-6.0m

329.5x228x70.3mm / 2660g

329,5x228,0 mm2

329.5x228.0 mm2

30641

max. 10W

650lm

138x100x39mm / 430g

138,0x100,0 mm2

138,0x100,0 mm2

138,0x100,0 mm2

138,0x100,0 mm2

30642

max. 15W

930lm

138x100x39mm / 480g

30643

max. 35W

2500lm

225x170x70mm / 1530g

225,0x170,0 mm2

225,0x170,0 mm2

225,0x170,0 mm2

225,0x170,0 mm2

30644

max. 50W

3700lm

225 x170x70mm / 1640g

30780

max.100W 7900lm

357.3x307.3x93.8mm / 6600g

357,3x307,3 mm2

357,3x307,3 mm2

357,3x307,3 mm2

357,3x307,3 mm2

30781

max.150W 11020lm

357.3x307.3x93.8mm / 6600g

30645

max. 70W

5000lm

329.5x228x70.3mm / 2660g

30646

max. 10W

670lm

138x100x39mm / 430g

30647

max. 15W

1130lm

138x100x39mm / 480g

30648

max. 35W

2700lm

225x170x70mm / 1530g

30649

max. 50W

3800lm

225x170x70mm / 1640g

30778

max.100W 8500lm

357.3x307.3x93.8mm / 6600g

30779

max.150W 12110lm

357.3x307.3x93.8mm / 6600g

Max projected 

area

 

Summary of Contents for 30640

Page 1: ...cht montieren 1 8 6 0m 1 Prüfen Sie den Packungsinhalt auf Unversehrtheit 2 Wählen Sie einen geeigneten und sicheren Montageort 3 Montagematerial ist nicht im Lieferumfang enthalten 4 Markieren Sie die Position der Befestigungslöcher mittels Befestigungsbügel und Stift 5 Bohren Sie die Befestigungslöcher mit geeignetem Werkzeug 6 Befestigen Sie das LED Flutlicht mit Ihrem Montagematerial LED Flutl...

Page 2: ...Choose a suitable and safe mounting place 3 Select the mounting material according the choosed surface material Mounting material is not included 4 Mark the mounting hole positions by mounting bracket and pencil 5 Drill the mounting holes with suitable tool 6 Attach the LED Flood Light with your mounting material Install the LED Flood Light 1 0mm 1 0mm 1 0mm 1 Switch off the fuse and check the abs...

Page 3: ...perte de la garantie et de la responsabilité axclusion Utiliser uniquement dans une ambiance sèche Montez le Phares à LED 1 8 6 0m 1 2 Sélectionnez une place d installation adéquate et sécuritaire 3 Sélectionnez le matériel de montage en fonction du matériau de surface sélectionné Le matériel de montage n est pas inclus 4 5 6 Fixez la Phares à LED avec votre matériel de montage Connecter le Phares...

Page 4: ...ticare i fori di montaggio con un attrezzo adatto 6 Fissare la Luce di inondazione del LED con l hardware di montaggio Collegare la Luce di inondazione LED 1 0mm 1 0mm 1 0mm 1 Spegnere il fusibile e controllare l assenza di tensione 2 Far scorrere le estremità dei cavi della Luce di inondazione del LED così nel blocco terminale che il rispettivo colore del cavo della Luce di inondazione del LED co...

Reviews: