NOTICE
1. If somehow user cannot get video output, please try to adjust EDID dip switch to “[pin2,pin3,pin4]=[
↓
-
↑
-
↓
]” or “[pin2,pin3,pin4]=[
↑
-
↓
-
↓
]” for trouble shooting. Under “[pin2,pin3,pin4]=[
↓
-
↑
-
↓
]”, there
will be video output. The only requirement is that the display has to support at least Full HD. If default
Full-HD EDID still cannot work, user can switch to “[pin2,pin3,pin4]=[
↑
-
↓
-
↓
]” to learn the EDID from
output 1 to customize the EDID information.
(Please note that the display with lowest resolution
must be connected to output 1)
Select to [pin2,pin3,pin4]=[
↓
-
↑
-
↓
] - Full-HD(1080p@60) – 8bit 2D video & 2ch audio
1) Set the dip switch to “[pin2,pin3,pin4]=[
↓
-
↑
-
↓
]”
2) Power on the device
Select to [pin2,pin3,pin4]=[
↑
-
↓
-
↓
]– Learning EDID from output 1
1) Set the dip switch to “[pin2,pin3,pin4]=[
↑
-
↓
-
↓
]”
2) Power on the device
3) It will automatically learn EDID from output 1
[NOTE]
a. If the user wants to change EDID mode, please power cycle the device after setting dip switch.
2. While connecting a new monitor to the splitter under “[pin2,pin3,pin4]=[
↓
-
↓
-
↓
]”(under auto EDID
analysis learning mode), experiencing a short period of time without displaying might be expected.
The splitter will do Automatic EDID learning and generate the best EDID among all connected
monitors
3. Firmware update is proceeded through Mini-USB.
1) Save the firmware file(.bin) & software in the same folder.
2) a) Power on the device, b) connectthe Mini-USB cable between PC and device, & c) set the PIN1
dip switch to “On [
]”(firmware update mode)
3) Open firmware update software and then device will start to update firmware automatically.
4) After update process is done, software will show “Success” message and then be closed
automatically.
5) Set the PIN1 dip switch to “Off [
]]”(working mode)
6) Power cycle the device