1 0
1
D
.
escription of the identification label
For an easiest repair, replacement or increasement
of the existing monitors, fill the identifying label
information
.
MASTER:
.
master monitor
SLAVE:
.
slave monitor
INTER: N
.
ot used
A1: N
.
ot used
CODE:
).
push button code (page
102
: Not used.
STAIR
MONITOR DESCRIPTION
H
andling the end of line jumper
.
The end of line jumper is situated on the CN2 connector, which is
found on the back of the monitor. It has three positions
:
Set to the centre position when there are no
parallel monitors
. (Automatic mode)
If there is a parallel monitor, set to this position on
the first monitor Deactivated mode
. (
)
CN2
CN2
CN2
If there is a parallel monitor, set to this position on
the last monitor Activated mode
. (
)
End of
line jumper
Example configuration of the end of line
jumper in
nitors
the mo
For more details, see
.
installation diagrams on page
s
to 1 .
123
35
*
*
Factory Default
End of line
resistor removed
End of line
resistor installed
109
MONITOR DESCRIPTION
D
.
escription of the Tekna R5
monitor
Col SU-R5
F
unction push buttons
.
a.
b.
c.
d.
e.
f .
g.
h.
i .
j .
k.
l .
m.
Telephone handset
.
C
.
olour screen
.
Inoperative push buttons
.
On-Off light indicator
.
Function push buttons
C
.
ord
A
.
ttachment holes
.
Identification label
.
Connecting points
C
.
N2 connector
C
.
able slot
C
.
olour control
.
Brightness control
g
l
k
m
j
i
h
a
b
f
e
c
d
Distributor
00000000000
v.xx
MASTER
INTER
A1
SLAVE
CODE
ESCALERA
STAIR
PISO
FLOOR
PUERTA
DOOR
ATENCIÓN
Alta tensión. No abrir la tapa.
Manipular sólo por personal
del servicio técnico.
WARNING
High voltage. Don't open cover.
Handle only by technical service.
SN
CODE
REF.
TEKNA R5 COL SU-R5
11742 0
5 4A
00000000000
v.xx
MASTER
INTER
A1
SLAVE
CODE
ESCALERA
STAIR
PISO
FLOOR
PUERTA
DOOR
ATENCIÓN
Alta tensión. No abrir la tapa.
Manipular sólo por personal
del servicio técnico.
WARNING
High voltage. Don't open cover.
Handle only by technical service.
SN
CODE
REF.
TEKNA R5 COL SU-R5
11742 0
5 4A
The image from the master door panel can be viewed if the handset is on the cradle If not,
.
audio and video communication can be established with the door panel that has been
configured with the autoswitch-on function This function is disabled if a communication is
.
already established.
Du
, if there are SU-R5 Relay Units "second
ring call reception and communication processes
door" (see manual TSU-R5 ML) in the installation, pressing each time the image will switch
(in carousel mode) from the door panel to the camera connected to the SU-R5 Rele Unit(s).
With the handset on the cradle, hold pressed for 1 second to turn the monitor on or off For a
.
period of 45 seconds after the monitor is turned on, it will only be able to receive calls
.
With the handset off the cradle, a call can be made to the master porter's exchange
.
Du
.
ring call reception and communication processes, it allows lock release activation
Du
, if there are SU-R5 Relay Units "second
ring call reception and communication processes
door" (see manual TSU-R5 ML) in the installation, two rapid presses open the door release
of the "second door" or the door release of the SU-R5 Relay unit selected.