background image

WIRING DIAGRAMS:

One apartment kit (NX5110 THERA kit) and Golmar DC lock release.

11

NA2

+

AP-

C1 NA1

AP+

C2 AP+ AP- P1 P2 BUSBUS

Relay 2

Relay 1

_

12Vdc

Lock release

max. 12 Vdc/270mA

N

L

CN

Mains

100~240Vac

BUS (M) BUS(PL)

FA-

2

GB /A

ON

1     2    3     4     5     6

AP

SW1

( )

1

( )

1

Access

panel

door

THERA

BUS

CODE 0

Two apartment kit (NX5220 THERA kit) and Golmar DC lock release.

Configuring the end of line
in the last monitor.

.

Dip 6 to On

NA2

+

AP-

C1 NA1

AP+

C2 AP+ AP- P1 P2 BUSBUS

Relay 2

Relay 1

_

12Vdc

Lock release

max. 12 Vdc/270mA

ON

1     2    3     4     5     6

*

AP

SW1

( )

1

( )

1

Important:

For AC lock releases or a second lock release, see diagram

Connection of Golmar AC and DC lock releases

on page 18.

( )

1

Access

panel

door

BUS

CODE 0

Distances and Cross-Sections:

Twisted pair 2x0.75mm

2

Twisted pair

mm

2x1

2

60m

A

60m

B

10m

C

80m 80m 15m

Cable

BUS

CODE 16

FA-

2

GB /A

A

B

C

APARTMENT

1

APARTMENT

2

*

*

Configuring the end of line
in the last monitor.

.

Dip 6 to On

*

Distances and Cross-Sections:

FA-

2

GB /A

A

B

Twisted pair 2x0.75mm

2

Twisted pair 2x mm

1

2

60m

A

60m

B

10m

C

80m 80m 15m

Cable

C

APARTMENT

1

THERA

THERA

THERA

THERA

THERA

L

N

L

CN

Mains

100~240Vac

BUS (M) BUS(PL)

FA-

2

GB /A

L

STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT – VILLAS

Summary of Contents for TKIT632

Page 1: ...USER MANUAL Code 50121904 T EN KIT632 THERA REV 0 1 1 6 G 2 Video Door Entry B System Kit 2 wire installation Stainless Steel Nexa Modular...

Page 2: ...door panel power supply distributors camera unit GSM interface monitors and telephones Use Golmar cable 2x1mm RAP 2150 Always follow the instructions contained in this manual Introduc 2 tion Contents...

Page 3: ...If another visitor tries to call a telephone tones will be heard to indicate that the system is busy and LED will illuminate If vocal synthesis is activated the message System is busy try later will...

Page 4: ...external door opening button Relay 2 Input for external call button push button 1 Input for external call button push button 2 Connection BUS non polarised Connection BUS non polarised Push button nu...

Page 5: ...etc To obtain optimum video door entry system image quality avoid direct contact from light sources sunshine street lights etc Positioning the embedding box DOOR PANEL INSTALLATION Preparing the cabl...

Page 6: ...rtment 2 will receive the call and only the monitor assigned with code 16 will show the door panel image If the call is answered from any other monitor in the apartment the image on the monitor assign...

Page 7: ...door panel is communicating if there is more than one door panel LED will turn on for 3 seconds While calling and the monitor is in Do not disturb mode LED will turn on for 4 seconds While calling apa...

Page 8: ...ow these steps Within 10 seconds of connecting power to the door panel press any call push button on the door panel Keep the call push button pressed until the vocal synthesis volume is heard and door...

Page 9: ...The selected contact type will apply to both Relay 1 and Relay 2 Description Normally open N O Normally closed N C Closing the door panel Once the door panel has been correctly wired configured and a...

Page 10: ...2 video door entry system with Golmar Thera monitors Install the power supply in a dry and protected place free from the risk of water drip or projections To prevent electric shock do not remove the p...

Page 11: ...c 270mA ON 1 2 3 4 5 6 AP SW1 1 1 Important For AC lock releases or a second lock release see diagram Connection of Golmar AC and DC lock releases on page 18 1 Access panel door BUS CODE 0 Distances a...

Page 12: ...le Distances and Cross Sections NA2 AP C1 NA1 AP C2 AP AP P1 P2 BUSBUS Relay 2 Relay 1 _ 12Vdc Lock release max 12 Vdc 270mA ON 1 2 3 4 5 6 AP SW1 1 1 BUS CODE 1 BUS CODE 2 BUS CODE 3 BUS CODE 0 NA2 A...

Page 13: ...witch to On AP Distances and Cross Sections DP GB2A A C B C Important For AC lock releases or a second lock release see diagram Connection of Golmar AC and DC lock releases on page 18 1 1 NA2 AP C1 NA...

Page 14: ...SW1 BUS BUS BUS BUS D2 D1 D2L 2 GB BUS BUS CODE 1 CODE 0 Do not change the factory default position of the configuration jumper 1 OFF 1 End of line OFF End of line 1 1 Distances and Cross Sections 2...

Page 15: ...iagram Connection of Golmar AC and DC lock releases on page 18 1 1 NA2 AP C1 NA1 AP C2 AP AP P1 P2 BUSBUS Relay 2 Relay 1 _ 12Vdc ON 1 2 3 4 5 6 SW1 1 BUS BUS BUS BUS D C B A DP 2 GB A D Twisted pair...

Page 16: ...OFF 1 End of line 1 Distances and Cross Sections D2L 2 GB A C B C 2 2 Twisted pair 2x0 75mm 2 Twisted pair 2x mm 1 2 60m A 60m B 30m C 80m 80m 40m Cable 10m D 15m D Important For AC lock releases or...

Page 17: ...NA2 AP C1 NA1 AP C2 AP AP P1 P2 BUSBUS Relay 2 Relay 1 _ 12Vdc NA2 AP C1 NA1 AP C2 AP AP P1 P2 BUSBUS Relay 2 Relay 1 _ 12Vdc NA2 AP C1 NA1 AP C2 AP AP P1 P2 BUSBUS Relay 2 Relay 1 _ 12Vdc NA2 AP C1...

Page 18: ...To the FA GB2 A power supply 1 Lock release max 12 Vdc 270mA Connection of 2 AC lock release with AP SEC PRI TF 104 Access panel door ON 1 2 3 4 5 6 SW1 Access panel door ON 1 2 3 4 5 6 SW1 WIRING DIA...

Page 19: ...NOT S E 19 STAINLESS STEEL NEXA MODULAR GB2 VIDEO SYSTEM KIT VILLAS...

Page 20: ...stemas de comunicaci n S A Golmar se reserva el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any mo...

Reviews: