golmar TEKNA-S TWIN Quick Manual Download Page 4

Avoid dusty or smoky environments or locations near sources of heat. The monitor can be fixed to an electrical embedding box or

directly to the wall.

For further information, see the TTekna

Gtwin manual

S

.

Important:

Hands-free monitor for the Gtwin system with button and coded panels.

Remember to remove the protective covering from the front of the monitor once installation is complete.

Embedding box

Location

Surface

DESCRIPTION OF THE TEKNA-S GTWIN MONITOR

2

DESCRIPTION

DESCRIPTION OF THE CONNECTION TERMINALS

FUNCTION BUTTONS

3

OPERATION

INSTALLATION

ADVANCED PROGRAMMING OF THE TEKNA HF GTWIN MONITOR

In standby and with the handset off the hook: it activates the intercom between 2 devices in the same apartment or in different

apartments (this feature must be pre-programmed, see the TTEKNA S GTWIN, pp. 12-15).

During call reception and communication processes, it enables the main lock release to be activated.

In standby and with the handset on the hook: it enables the image from the door panel configured as main to be viewed (if the

channel is busy, a number of short audible tones on the monitor will indicate so); if the handset is then picked up, it
enables audio and video communication with the door panel to be established.

During a call process: it enables the slave monitors (in the same apartment) to capture the image of the door panel, with the

image on the monitor that was displaying it disappearing.

In standby and with the handset off the hook: it activates the intercom between 2 devices in the same apartment or in

different apartments (this feature must be pre-programmed, see the TTEKNA S GTWIN, pp. 12-15).

During a call, communication or auto-spy process: it enables the secondary lock release to be activated: one press will

activate the lock release for 1 second.

In standby and with the handset off the hook: it enables a call to be made to the guard unit.
In standby and with the handset off the hook: it activates the intercom between 2 devices in the same apartment or in different

apartments (this feature must be pre-programmed, see the TTEKNA S GTWIN, pp. 12-15).

Note:

Activation of the

function disables the

function.

'intercom'

'call to guard unit'

In standby and with the handset on the hook: it enables programming mode to be entered or exited by pressing and holding

for 5 seconds, a number of short audible tones will indicate that the monitor is in programming mode and the status LED
will blink slowly (yellow) or a number of long audible tones will indicate that the monitor has saved and left programming
mode, and the status LED will turn off.

No function.

Handset.
4.3

TFT colour screen.

Communication with hearing aids. Set the hearing aid switch to position T.
Function/programming buttons.

Telephone cord.
Cord connector.
Brightness control.
Colour control.
Monitor status LED:
- No volume: LED blinking red rapidly.
- Doctor mode: LED blinking green.
- State of the door on the main panel:

LED illuminated red. (see the TGtwin System

Manual, p. 10).

-

e

State of the door on the slav panel:

G

LED blinking red. (See the T twin System

Manual, p. 10).

- Programming mode:

LED blinking yellow.

Monitor indicator LED:
- Standby: Off.
-Call/communication/auto spy:

LED illuminated green.

Connector fixings.
J2 jumper (end of line) or EL-566

in-out unit connector (see the TTekna S
Gtwin manual).

SW2 configuration switch.
SW1 configuration switch.
CN5 connector (no function).
CN1 connection terminals.
CN2 connection terminals.

a.

b.

c.

d.

e.

f.

g.

h.

i.

j.

k.

l.

m.

n.

o.

p.

q.

Screws supplied with the
embedding box.

Advanced programming enables the monitor's default settings to be changed:

With the monitor in standby: Press button

for more than 5 seconds to access

3 short

'programming mode,'

audible tones will confirm this and the monitor's programming LED will blink (yellow) slowly, indicating that
button

an be released.

..... c

Then adjust the settings as required:

To activate doctor mode: Press button

once, an audible tone will indicate that the function is activated;

if it is

pressed again, an audible tone will indicate that the function will change its status to deactivated and so on

. The

monitor's programming LED will blink (green) slowly when the monitor exits programming mode and is in standby.

- Changing the door panel ringtone melody:

The monitor enables selection of the ringtone (5 different tones).

- Activating/deactivating the doctor mode function: Doctor mode not activated (default setting).

The 'doctor mode' function enables the main lock release to be activated automatically 3 seconds after making a call from the

door panel without having to establish communication or press door release button

. The call ends after 15 seconds and

the channel becomes free.

(Only the master monitor should be configured with 'doctor mode').

Select the ringtone melody: Press button     until the desired melody is heard 'carousel mode.'

- Changing the ringtone melody

the apartment front door:

of

The monitor enables selection of the ringtone

the apartment front door (5 different tones).

of

Select the ringtone melody

the apartment front door: Press button

until the desired melody is heard 'carousel

of

mode.

- Exiting programming mode:

To exit

press button

for more than 5 seconds, 1 short and 2 long audible tones will confirm this

'programming mode,'

and the programming LED will turn off, indicating that button

can be released.

Note:

When exiting programming

mode, if 'doctor mode' has been activated, the monitor's status LED will blink (green), see p. .

2

-

Call reception: During call reception, the image will appear on the master monitor, and the indicator LED on the master and slave

monitors will illuminate (green). If the call is not answered within 60 seconds, the status LED on the master and slave monitor(s) will
turn off. LED

on the door panel will turn off and the channel will become free.

-

To establish communication, pick up the monitor handset, the status LED will remain illuminated (green), LED

on the door panel will

now illuminate and LED

on the door panel will turn off.

: the handset enables communication

Communication with hearing aids

with hearing aids equipped with T-mode, making conversation possible (inductive loop).

-

Guaranteed communication time is 90 seconds (configurable); after 90 seconds of guaranteed communication time, the channel will

become free.

-

To end communication, hang up the handset, the indicator LED on the monitor and LED

on the door panel will now turn off and the

channel will become free.

-

To open the main or secondary door, press the corresponding door release button

/

during the call or communication processes:

one press will activate the lock release for 1 second (configurable main door) and, with the opening of the main door, LED

on the door

panel will also illuminate for 1 second.

EN

EN

a k

b

c

q

m

n

p

d

o

j

i

h

g

J2

CN2

CN1

CN5

SW1 SW2

l

k

e

f

TEK

A

N

-S

TWIN

G

12050225

V

.

XX

1509020

0

00 0

SN

ADDRESS

I T

N ER

A1

SLAVE MASTER

AT

C

EN IóN

Al

ten

ta

sión. No abri l tapa.

r a

Ma p a s

ni ul r ólo por p rsonal

e

de s rvici

é

ico.

l e

o t cn

W

ING

ARN

.

GOLMAR S.A

High Voltage  Do ´t

en cover

.

n op

C/ S li ,

i ci  13

Handle on

y e

nica

ly b t ch

l service

08940 - SPAIN

ESCALERA

STAIR

PISO

F O

L OR

PU

T

ER A

D O

O R

1 2 3 4 5 6 7 8

1 2

Bornes de conexión C 1:

N

Bornes de conexión

:

CN2

Communication bus input to monitor (non-polarised).
Communication bus output to additional monitor/

telephone (non-polarised).

LINE IN:
LINE OUT:

CP

LINE

OUT

LINE

IN

Door bell button input.
Output (positive) to auxiliary call repeater SAV-GTWIN.
Output (negative) to auxiliary call repeater SAV-GTWIN.

CP :
S+ :
S   :

S+ S

_

1.60m

x

4

30

- Adjusting the call volume:

Maximum volume (default setting).

The monitor enables call volume control (maximum/minimum/no volume).

Press button

until you hear the desired volume. Options: maximum, minimum and no volume (if set to 'no volume,' the

monitor's status LED will blink red rapidly when the monitor exits programming mode and is in standby) 'carousel' mode.

Summary of Contents for TEKNA-S TWIN

Page 1: ...n etc ver manual T GTWIN MANUALSISTEMA c d 50122345 https doc golmar es search manual 50122345 Valor de f brica ON ON ON OFF ON ON ON OFF TTEKNA GTWIN ES S GR REV 0122 Microinterruptor de configuraci...

Page 2: ...llano Pulsar el bot n hasta escuchar eleccione la melod a para el tono de llamada la melod a deseada modo carrusel Ajuste del volumen de llamada Volumen m ximo valor por defecto El monitor permite el...

Page 3: ...etc see the GTWIN SYSTEM MANUAL c d T 50122345 https doc golmar es search manual 50122345 Factory default ON ON ON OFF ON ON ON OFF SW1 configuration switch DIPswitch 1 Must be OFF DIPswitches 2 to 8...

Page 4: ...tings as required To activate doctor mode Press button once an audible tone will indicate that the function is activated if it is pressed again an audible tone will indicate that the function will cha...

Page 5: ...zie de handleiding TGTWIN MANUAL SISTEMA https doc golmar es search manual 50122345 Fabrieksinstelling DIP Schakelaar Sw1 Dip schakelaar 1 Moet op UITstaan De schakelaars dip2 tot dip8 hiermee wordt d...

Page 6: ...15 TTEKNAS GTWIN Opmerking de activering van de intercomoproep functie schakelt de functie oproep naar het portiersmodule uit In rust en met de hoorn op de haak hiermee kunt u de instellingenmodus ope...

Page 7: ...outrosesquemas de instala o etc ver manual TGTWIN MANUAL SISTEMA c d 50122345 https doc golmar es search manual 50122345 Valor de f brica ON ON ON OFF ON ON ON OFF Microinterruptor de configura o Sw1...

Page 8: ...Selecione a melodia para o som de chamada Carregue no bot o at escutar a melodia pretendida do modo carrossel Mudar a melodia de chamada da porta do patamar da habita o O monitor permite selecionar o...

Reviews: