background image

First of all we would like to thank and congratulate you for the purchase of this product 

manufactured by Golmar.

The commitment to reach the satisfaction of our customers is stated through the ISO-9001 

certification and for the manufacturing of products like this one.

Its advanced technology and exacting quality control will do that customers and users enjoy with the 

legion of features this system offers. To obtain the maximum profit of these features and a properly wired 
installation, we kindly recommend you to expend a few minutes of your time to read this manual.

O

O
O

To make a call the visitor should press the push button corresponding to the apartment he wishes 

to contact. An acoustic tone will be heard confirming the call as the push button is pressed. At 
this moment the call will be received at the telephone in the dwelling.

To establish communication pick up the telephone handset.
To open the door, press the door release push button at any moment.

O
O

O

Do not use excessive force when tightening the transformer connector screws.
Install the equipment without the power connected. Disconnect from power before any system 

modification. Check that the input voltage is lower than 230Va.c.

Before to connect the system, check the connections between door panel and telephones, and 

the transformer connection. Do always follow the enclosed information.

O
O
O
O
O
O

Audio system with 2 wires installation.

Weatherproof (IP-44) and vandal resistant (IK-09) door panel

.

Just 1 TF-104 transformer (12Va.c., 1.5A).
Electronic call with acoustic acknowledgement signal.
a.c. lock releases activation.
Telephone with call reception volume control and additional push button (T-922).

13

14

INTRODUCTION

SYSTEM CHARACTERISTICS

SYSTEM OPERATION

STARTING RECOMMENDATIONS

POWER SUPPLY INSTALLATION

DOOR PANEL INSTALLATION

1650

1850

1450

The upper part of the door panel should be placed at 1,65m. height roughly. The hole dimensions
     are:

                                             131(An) x 131(Al) x 45(P) mm.

The door panel has been designed to be placed under most of the environmental conditions.
     However it's recommended to take additional cautions like rainproof covers.

DIN 46277

f

3,5 x  25

DIN-7971

 

f

3,5 x 25

DIN-7971

nstalling the TF-104 transformer.

I

To install the transformer directly on the wall,
     insert the fixing flanges.
     Drill two holes of 

Ø6

mm. and

     insert the wallplugs.
     Fix the transformer with the specified
     screws.

The transformer can be installed on a DIN guide (3 units) simply pressing it.
     To disassemble the transformer from the DIN guide, use a plain screwdriver to lever
     the flange as shown on the picture.

The transformer must be installed in a dry and
     protected place. It's recommended to protect
     the transformer by using a thermo-magnetic
     circuit breaker.

mbedding box positioning.

E

Summary of Contents for T222ML

Page 1: ...lmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior notice golmar golmar es www golmar es Kits Portero Electr nico instalaci n...

Page 2: ...brepuertas en cualquier momento O O O No apretar excesivamente los tornillos de la regleta del alimentador Cuando se instale el equipo hacerlo sin alimentaci n Desconectar la alimentaci n para cualqui...

Page 3: ...ujeci n Conectores para cord n telef nico Pulsador adicional s lo T 922 Pulsador abrepuertas Regulador de volumen de llamada Pulsador de colgado a d c e g b Abrir el tel fono para instalarlo introduci...

Page 4: ...extremos O Volumen de audio inadecuado w Ajustar los niveles de audici n tal y como se muestra en la p gina 3 En caso de acoplamiento reducir el volumen hasta que desaparezca el acoplamiento O El tel...

Page 5: ...serrer de fa on excessive les vis du connecteur de l alimentation Lors de l installation ou de toutes interventions sur le syst me veiller couper l alimentation lectrique Assurer vous que la tension r...

Page 6: ...mbin Grille HP Micro Syst me d accrochage du combin Prise pour connecteurs du cordon Touche de commande suppl mentaire T 922 uniquement Touche de commande de la g che el ctrique Touche de fin communic...

Page 7: ...e expliqu page 9 En cas d effet Larsen r duire le volume jusqu disparition de celui ci O L appel sonne en continu il n y a pas d audio et la commande de g che ne fonctionne pas w Les c bles connect s...

Page 8: ...r panel and telephones and the transformer connection Do always follow the enclosed information O O O O O O Audio system with 2 wires installation Weatherproof IP 44 and vandal resistant IK 09 door pa...

Page 9: ...e slots and rotate it as shown Avoid to place the telephone near to heating sources in dusty locations or smoky environments The telephone can be fixed using an electrical embedding box or directly on...

Page 10: ...r voltage between SEC terminals it should have 12 to 17Va c If not replace the transformer wSome of the installation wires are disconnected wIf only the door open function is working wires connected t...