41
onfiguration switches
C
.
On installation with one monitor only, set it as master;
on installations with two monitors, set as master the monitor where the door
panel(s) is connected and the other monitor as slave.
unction push buttons.
F
Master
The configuration switches are placed on the monitor base.
On installations with two monitors, set as slave the monitor that is not connected
the door panel.
IMPORTANT: Modify the configuration switches
On installations with two monitors, set as master the monitor where the door
panel(s) is connected.
without the power connected.
all volume control.
C
The monitor allows to regulate the call volume from maximum to
minimum value, with the regulator placed in the right side of the
monitor.
MONITOR DESCRIPTION
42
Slave
MONITOR INSTALLATION
emove the bracket installation.
R
Unscrew the monitor bottom screws.
Remove the bracket installation of the monitor.
ix the bracket installation to the wall.
F
Avoid to place the monitor near to heating sources,
in dusty locations, wet or smoky environments.
The bracket can be fixed using an electrical emmbeding
box or directly on the wall. To install directly over the
wall, drill two holes of 6mm. and use the supplied
screws.
The upper part of the bracket must be placed at 1,60m.
height roughly. The minimum distance between the
monitor and the closest object must be 5cm.
*
*
Factory default.
M
S
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
!
DO NOT OPEN, RISK OF ELECTRIC SHOCK
INSTALL AWAY FROM MOISTURE OR HIGH TEMPERATURE
INSTALL IN A WELL VENTILATED AREA
3
2
1
P2-
P2+
P1+
P1-
M
S
-
+
1370 SII COLOR 7"
C A U T I O N
RISK OF ELECTRIC SHOCK
DO NOT OPEN
!
DO NOT OPEN, RISK OF ELECTRIC SHOCK
INSTALL AWAY FROM MOISTURE OR HIGH TEMPERATURE
INSTALL IN A WELL VENTILATED AREA
3
2
1
P2-
P2+
P1+
P1-
M
S
-
+
1370 SII COLOR 7"
Nº serie 1304010000
C A U T I O N
RISK OF ELECTRIC SHOCK
DO NOT OPEN
!
DO NOT OPEN, RISK OF ELECTRIC SHOCK
INSTALL AWAY FROM MOISTURE OR HIGH TEMPERATURE
INSTALL IN A WELL VENTILATED AREA
Push button to stablish / finish audio communication or intercom function (only available on
systems with additional monitor, for description and connection see page 44 & 45).
Push button to activate the lock release. During call reception, communication and
autoswitch-on processes, it allows lock release activation. During activation, the picture will
disappear from the monitor screen.
:
(
).
Push button for a
It allows to visualize the picture and to listen the audio with the
door paneI during 40 seconds (in case of systems with two door panels, pushing each time,
the picture and audio will switch from a door panel to the other one), to stablish audio and
video communication with the door panel press push button. The communication will last
for 80 seconds or until press push button monitor again.
Push button to activate the auxiliary device. D
, activate the auxiliary device (see page 46). During activation, the
picture will disappear from the monitor screen.
With system in rest ring tone selection monitor, for description see page
44
utoswitch-on.
uring call reception, communication and
autoswitch-on processes