O
To make a call the visitor should press the button corresponding to the desired apartment. An
acoustic tone will be heard confirming the call is in progress. At this moment the call will be received
at the monitor in the dwelling. During the call the visitor can correct his call by pressing a push button
corresponding to a different apartment, in which case the original call is cancelled.
O
In systems with several access doors, the other door panel(s) will be automatically disconnected. If a
visitor tries to call from another door panel an acoustic tone will be heard confirming the system is
busy.
O
The call lasts for 45 seconds and the image appears on the master monitor for 3 seconds after
receiving the call without the visitor knowing. To see the image on a secondary monitor pick up its
handset, causing the image being watched to disappear from the monitor display. If the call is not
answered in 45 seconds, the system will be freed.
O
To establish communication, pick up the monitor/telephone handset.
O
The communication will last for one and a half minutes or until the handset is replaced. Once the
communication has finished the system will be freed. If the push button of another apartment is pressed
by mistake, press the push button of the correct apartment and the communication is cancelled.
O
To open the door of the (master) panel, press the lock release push button. To open the second door,
press the lock release push button twice rapidly during the processes of calling or communication.
O
To display the image from the second camera (if connected), press the push button on the monitor. By
pressing each time, the image will switch from the door panel to the camera connected to the SU-R5
relay unit.
O
If more than one SU-R5 relay unit is fitted (up to 4 in cascade), it is possible to monitor the visitor
through the doors of the building. By pressing the push button on the monitor, the image will switch
(in carousel mode) from the door panel to the camera of the relay unit with address 1 and so on
successively following the address order of the relay units until the image of the camera of the last unit
with address 4 is displayed returning then to the image from the panel.
O
In systems with several access door panels, “carousel mode” is carried out from the door panel from
which the call was made.
O
If, in any of the SU-R5 relay units, there is no camera (DIP switch 5 OFF) when switching to one of
these relay units, the monitor will not display any image (blue screen).
O
During the monitoring of the visitor through the doors of the building, pressing the monitor's lock release
push button will only open the door of the panel if it is selected at that moment. Two rapid presses of the
lock release push button will open the door of the SU-R5 relay unit selected at that moment.
O
If the call or communication time ends during visitor monitoring, the process will be cancelled. If the door
panel from which the call is made has its autoswitch-on function enabled, it is possible to continue
"
"
tracking the visitor from the monitor by pressing the push button on the monitor until selection of the
SU-R5 relay unit where the process was previously ended.
O
:
Note
If communication is made between a telephone and the door panel, the telephone can only
open the door of the door panel and the door of the SU-R5 relay unit with address "1".
O
Important:
If more than one SU-R5 relay unit is connected to the system, the addresses configured in
the relay units must be correlative (in order: 1st unit with address '1', 2nd unit with address '2', 3rd unit
with address '3' and 4th unit with address '4').
If the relay units have not been configured with correlative addresses, instead of tracking the visitor
through the successive doors (relay units) of the building, the system will return to the door panel.
3
SYSTEM OPERATION
4
OPERATING MODES
2
Tekna SU-R5
monitors/telephones
MONIT
ORS / TELEPHONES
5
5
5
3
M
INPUT
AP
OUTPUT
Al.
SU-R5 RELAY UNIT
2
FA-PLUS/C
Vista Nexa Panel
M =Master.
S =Slave.
M
M
M
M
-
+
/
1+Coax
CV
2C
2nd Camera
2nd door functions
SW1
R. Line
R. Line
R. Line
Installation modes with 1 SU-R5 relay unit:
5
Continued
Address "1"
( )
*
VIST
A
SYSTEM
DOOR P
ANELS
5
CV
Vc.c
Installation with 1 relay unit (1 power supply unit without ( ) "AP").
Important
:
If there are (slave) access door panels, they will have their own power supply unit.
The Stadio door panel with the EL502 module to connect the AC lock release will have its own power
supply unit.
Note
: The CD-Plus/R5 converter for porter's exchange, distributors, monitors and telephones should be
connected to the output of the SU-R5 relay unit, never between the door panel and the relay unit.
Installation diagrams on pages 17-18.
*
5