background image

86

85

amps wiring.

L

DOOR PANEL INSTALLATION

LOCK RELEASE INSTALLATION

nstalling the FA-PLUS and FA-PLUS/C power supplies.

I

DIN 46277

3,5 x  25

DIN-7971

 

f

3,5 x 25

DIN-7971

If the lock release will be installed in a metal door, use a
     

Ø3,5mm. drill and tap the hole

. In case of wood door,

     use a 

Ø3mm. drill

.

IMPORTANT: the lock release to be used must be of 12Vd.c.

If you are using a.c. lock releases, use one R-3 relay unit and
one TF-104 transformer to activate it, as it is shown on page 96.

M 4 x 8

f

3,5 x 25

 DIN-7972 

 DIN-963

POWER SUPPLY INSTALLATION

To install the power supply directly on the wall, drill two holes
     of 

Ø6

mm. and insert the wallplugs.

     Fix the transformer with the specified screws.

The power supply can be installed on a DIN 46277 guide
     simply pressing it. To disassemble the power supply
     from the DIN guide, use a plain screwdriver to lever
     the flange as shown on the picture.
The FA-Plus/C model uses 6 units over DIN guide
     and 10 units the FA-Plus model.

IMPORTANT: the maximum number of units that can be connected to a FA-Plus/C power

supply is 10, and 50 units in case of a FA-Plus model.
Link power supplies to connect more units than the specified as it's shown
on page 96.

The power supply must be installed in a dry and
     protected place. It's recommended to protect
     the power supply by using a thermo-magnetic
     circuit breaker and to use a ground connection.

ock release installation.

L

inal adjustments.

F

lose the door panel.

C

Fix the door panel by using the supplied
     screws.

Finish the door panel assembly by pressing
     the closing heads.

Once the nameplate labels are placed, wire the
     lamps from different modules and connect them
     to terminals L1 and L2 of the sound module.
If the number of door panel lamps is higher than eight,
     connect a TF-104 transformer between ~1 and ~2
     terminals of the sound module and change JP2 jumper
     position.

NOTE: Don't change JP1 jumper position. JP1 and JP2 jumpers are placed

on the left side of the sound module terminal connector.

If after starting the system it's considered that the audio
     volume isn't correct, proceed with the necessary
     adjustments as shown.
The telecamera has a pan and tilt mechanism built in
     to adjust the telecamera position.

In case of low light conditions, an external illumination
     can be activated by connecting a R-3 relay
     between terminals '+H' and 'L2' of the sound module.

Summary of Contents for Stadio Plus T500ML

Page 1: ...71 Stadio Plus Instructions manual Audio and Video door entry system digital installation T500ML rev 0205 ...

Page 2: ...half minutes or until the handset is replaced Once the communication has finished the system will be freed O To open the door press the door release push button during call or communication progresses with one press the door release operates during 3 seconds During the lock release activation an acoustic tone will be heard on the door panel confirming the lock release is activated O The monitor an...

Page 3: ...f the door panel should be placed at 1 65m height roughly The hole dimensions will depend on the number of door panel modules The door panel has been designed to be placed under most of the environmental conditions However it s recommended to take additional cautions like rainproof covers To obtain a good quality picture on video door entry systems avoid direct incidence from light sources reparin...

Page 4: ...N marked in the lower module and fix it by screwing the module shafts Place the module spacer between lower and next modules assuring that the spacer adjustment notches are inside the panel Fix the module by screwing the shafts Repeat this procedure in case of door panels with one more module the maximum number of modules placed vertically is three Insert the header UP marked in the last module an...

Page 5: ...el on the embedding box insert the hinges in the embedding box lockers as shown old the door panel on the embedding box H For a quality finish pass the push buttons wires through the spacer hole of the closest module 2 It s recommended to use wires of less than 0 25mm section IMPORTANT link the push buttons common terminal of the several push buttons modules The common terminal of the push buttons...

Page 6: ...6 circuits With 5 EL516 circuits With 6 EL516 circuits With 7 EL516 circuits With 8 EL516 circuits 8 7 15 22 6 15 15 36 5 15 15 15 50 4 15 15 15 15 64 3 15 15 15 15 15 78 2 15 15 15 15 15 15 92 1 15 15 15 15 15 15 15 106 0 15 15 15 15 15 15 15 15 120 To other encoders or push buttons 1 P2 1 P1 31 P4 61 P6 91 P8 16 P3 46 P5 76 P7 106 2 2 32 62 92 17 47 77 107 3 3 33 63 93 18 48 78 108 4 4 34 64 94 ...

Page 7: ... installations the EL562 module must be plugged in all the monitors and JP2 jumper of the EL500 circuit must be placed on the position specified on page 83 Refer to the specific installation diagram escription of the configuration dip switch D Set to ON the switch number 2 for monitor or telephones programming Once the programming progress is finished return the switch to OFF position The programm...

Page 8: ...case of a FA Plus model IMPORTANT Link power supplies to connect more units than the specified as it s shown IMPORTANT on page 96 IMPORTANT The power supply must be installed in a dry and protected place It s recommended to protect the power supply by using a thermo magnetic circuit breaker and to use a ground connection ock release installation L inal adjustments F lose the door panel C Fix the d...

Page 9: ... Floor Door Stair PLATEA Plus 0000000000 Nº serie a f g b e j l k m d i c h a b c d e f g h i j k l m Handset B W or color screen depending on the model Front film Function push buttons Cord Attachment holes Identification label Connecting points CN4 connector Three positions call reception volume control Cable slot Contrast control color control in case of color screen Brightness control Monitor ...

Page 10: ...onal device activation output twisted pair video signal Vin Malla Vout A D HZ INT SA CTO 2C A1 Vp Mp L562 module for video installations E with twisted pair cable andling the end of line jumper H hanging the front film C The end of line jumper is placed on the CN4 connector that can be located on the monitor base In case of twisted pair cable installations the end of line jumper is placed in the E...

Page 11: ...de In systems with more than one door panel the programming process shall be done on the master door panel only Switch off the monitor to be programmed Once the monitor is off press the door release push button With the door release push button pressed switch on the monitor To show that the system is ready for programming the door panel will reproduce a sound and the picture will appears on the mo...

Page 12: ...allows to call to the master porter s exchange During call reception and communication progresses allows the lock release activation a b c a b c erminal connector description T positive ground audio digital communication intercom auxiliary calling device output door bell push button input A D INT SA HZ A D _ SA INT HZ TELEPHONE INSTALLATION ix the telephone F It will be necessary to open the telep...

Page 13: ...slaves both monitors or telephones Make a call to check that the telephone has been succesfully programmed Repeat these steps to program the rest of telephones Once the programming has been finished set to OFF the programming switch If you don t the door panel will reproduce a sound to advise that the system is still into programming mode M R B O T R 3 TF 104 SEC CV CV D Malla Vin Ain Aout Vin Vou...

Page 14: ...istributor INSTALLATION DIAGRAMS ideo installation with coaxial cable v The installation diagram shows the connection of a video system with one or several door panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire the second panel as shown on the diagram In case of more than two door panels w...

Page 15: ... Terminal SECTIONS CHART 50m Distance 150m A A A D in out V V V M in out p d p d CV CV INSTALLATION DIAGRAMS ideo installation without coaxial cable v The installation diagram shows the connection of a video system with one or several door panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire ...

Page 16: ... A 1 00mm 2 50mm 0 25mm 0 25mm Terminal SECTIONS CHART 50m Distance 150m A A A D in out CV CV Place this power supply as closest as possible to the first telephone The installation diagram shows the connection of an audio system with one or several door panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one do...

Page 17: ...ART connector it will be possible to view the picture from the door panel on the TV screen Remove the end of line jumper that s placed on the CN4 connector Connect the coaxial cable between terminals 17 shield and 20 hot of the SCART connector ntercom function I Platea Plus monitor and T 940 Plus telephone have intercom facility between two units of the same apartment To enable this function check...

Page 18: ...nits with the exception of a shortcircuit between CTO and monitor or distributor terminals O Nothing operates w Check the output power supply voltage between and terminals it should have 17 5 to 18 5Vd c If not disconnect the power supply from the installation and measure again If it s correct now it means there is a short circuit in the installation disconnect the power supply from mains and chec...

Reviews: