background image

SCHEMATIC DIAGRAMS

tand alone operation.

S

44

The enclosed diagram uses a TF-104 transformer (12Va.c.) as access control module feeder.
(*) The enclosed varistor must be used when connecting a.c. lock releases.
The relay 1 operation depends on the programming and the relay 2 operation depends
     its wiring.
In case of simultaneous activation of two lock releases (see duplicated codes on page 41),
     an additional TF-104 transformer must be used.
In case of security lock releases with reversed operation (the lock release operates when
     no voltage is applied), connect the lock release between C2 and NC2 terminals,
     or program relay 1 as normally closed (see page 40).

Gray text: factory default

QUICK PROGRAMMING GUIDE

45

uick programming guide.

Q

0

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

3

7

8

4

9

5

6

6

6

0

4

0

0

0 3

0

0

3

3

2 7 1 8 2 8

3 1 4 1 5 9

1

1

1

1st code, Relay 1

1st code, Relay 2

Codes lenght (4, 5 or 6 digits)

2nd code, Relay 1

2nd code, Relay 2

3rd code, Relay 1

3rd code, Relay 2

4th code, Relay 1

4th code, Relay 2

5th code, Relay 1

5th code, Relay 2

6th code, Relay 1

6th code, Relay 2

7th code, Relay 1

7th code, Relay 2

8th code, Relay 1

8th code, Relay 2

Panic code

Installer PIN code

User PIN code

Relay 1: N/O (0)   N/C(1)

Keypad tones: Off (0)   On(1)

Relay 1: Single shoot (0)   Stable(1)

Relay 1: Activation time (01 to 20s.)

Relay 2: Activation time (01 to 20s.)

Panic: Activation time (01 to 20s.)

2

2

3

3

4

4

5

5

6

6

7

7

8

8

0

0

0

1

0

1

1

2

3

C2

NC2

NA2

B+ B- C1 N1

CN1

P

~ ~

3301/AL

Access control module

SEC

SEC

~

~

~

~

PRI

PRI

~

~

~

~

Mains

Mains

TF-104

transformer

(*)

(*)

1

4

7

2
5

8

3

6 0

9

C

TF-104

transformer

C2

NC2

NA2

B+ B- C1 N1

CN1

P

~ ~

SEC

~

~

PRI

~

~

Red

(*)

1

4

7

2
5

8

3

6 0

9

C

CN1

CV

1

5

4

PS

SN L1

N1

L2

N2

~1

~2

(*) The enclosed varistor must be used.

EL510

sound module

3301/AL

Access control module

TF-104

transformer

One access door audio systems with 1+'n' installation.

ombined on 'Stadio Plus' 

C

door panels.

Summary of Contents for Stadio Plus T3301ML

Page 1: ...el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior notice golmar golm...

Page 2: ...l 1 programable n c o n a estable o impulsional carga m xima 60W Rel 2 impulsional de tres contactos carga m xima 60W Tiempo de activaci n del modo impulsional programable para cada rel entre 1 y 20 s...

Page 3: ...lo si los muelles se colocan en las dos pinzas del cabezal inferior la apertura del m dulo se realizar hacia abajo si se colocan en las pinzas derechas de ambos cabezales la apertura ser hacia la izqu...

Page 4: ...almente cerrada rel 2 com n rel 2 salida normalmente abierta rel 2 salida p nico B B C1 N1 NC2 C2 NA2 P Para entrar en el modo de programaci n pulsar la tecla llave seguida del c digo secreto de gesto...

Page 5: ...en el campo 11 Define el tercer c digo de activaci n del rel 1 Proceder como en el campo 11 Define el octavo c digo de activaci n del rel 1 Proceder como en el campo 11 Define el cuarto c digo de act...

Page 6: ...ine el c digo de gestor para acceder al modo de programaci n Introducir siempre un c digo de 6 cifras Una vez introducido el c digo el m dulo emitir 2 tonos volver a introducir el c digo para confirma...

Page 7: ...control de accesos 3301 AL CV CV CO INH C2 NC2 NA2 CP B B C1 L1 L2 P N1 CN1 CN1 1 P 2 Transformador TF 104 Transformador TF 104 SEC PRI Red ombinado en placas C Stadio Plus Equipos de portero electr n...

Page 8: ...f brica GU A R PIDA DE PROGRAMACI N 13 u a r pida G 0 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 3 7 8 4 9 5 6 6 6 0 4 0 0 0 3 0 0 3 3 2 7 1 8 2 8 3 1 4 1 5 9 1 1 1 C digo 1 Rel 1 C digo 1 Rel 2 Longitud de los...

Page 9: ...Control d acc s autonome par clavier codes Stadio Plus T3301ML rev 0304 manuel d installation 14...

Page 10: ...s de montage de la notice de la plaque de rue Dans ce cas ne pas tenir en compte des explications pages 19 et 20 de ce manuel Introduction 17 Caract ristiques du syst me 17 Installation avec plaques S...

Page 11: ...es dans les fixations m talliques se trouvant aux extr mit s des t tes comme indiqu sur le dessin Si les tiges charni res sont plac es dans les fixations inf rieures l ouverture du module s effectuer...

Page 12: ...ction seulement en cas d oublie du code Quand le syst me est en marche changer la position du pontet pour r initialiser et remettre sa position normal DESCRIPTION DU MODULE PROGRAMMATION DU MODULE 20...

Page 13: ...7 d activation du relais 1 Proc dure identique 11 D fini le code 3 d activation du relais 1 Proc dure identique 11 D fini le code 8 d activation du relais 1 Proc dure identique 11 D fini le code 4 d a...

Page 14: ...confirmation Valeur usine 271828 D fini le code utilisateur qui permet d acc der au mode programmation Introduire toujours un code de 6 chiffres Une fois introduit ce code le module mettra 2 bips son...

Page 15: ...n fonctionnent en 12Vc a il est donc n cessaire d utiliser la varistance fournie avec le module contr le clavier codes ssemblage avec plaque de rue Stadio Plus A Modules microprocesseur EL500 EL501 ou...

Page 16: ...5 9 1 1 1 Code 1 Relais 1 Code 1 Relais 2 Nombre de termes du code 4 5 ou 6 Code 2 Relais 1 Code 2 Relais 2 Code 3 Relais 1 Code 3 Relais 2 Code 4 Relais 1 Code 4 Relais 2 Code 5 Relais 1 Code 5 Rela...

Page 17: ...Stand alone access control module Stadio Plus T3301ML rev 0304 30 Instructions manual...

Page 18: ...and override the content of pages 34 and 35 of this manual Wire and program the access control module as it s explained in this instructions manual Introdution 33 System characteristics 33 Installati...

Page 19: ...ition that must be passed through the header clips as shown For example if the hinges are placed on both clips of the lower header the module will open downwards if they are placed on the right clips...

Page 20: ...erminal relay 2 normally closed output relay 2 common terminal relay 2 normally closed output panic output B B C1 N1 NC2 C2 NA2 P To enter into the programming menu press key symbol and enter the inst...

Page 21: ...1 Proceed as detailed on 11 field It defines the 4th activation code of the relay n 1 Proceed as detailed on 11 field It defines the 1st activation code of the relay n 2 Proceed as detailed on 11 fiel...

Page 22: ...programming mode A 6 digits code must be always used Once this code has been introduced 2 acoustic tones will be heard introduce the code again and 4 slow acoustic tones will be heard to confirm the...

Page 23: ...systems with 4 n installation Several access doors systems with 4 n installation The 4 n systems use 12Va c lock releases the supplied varistor must be connected to the lock release ombined on Stadio...

Page 24: ...1 5 9 1 1 1 1st code Relay 1 1st code Relay 2 Codes lenght 4 5 or 6 digits 2nd code Relay 1 2nd code Relay 2 3rd code Relay 1 3rd code Relay 2 4th code Relay 1 4th code Relay 2 5th code Relay 1 5th co...

Reviews: