ne access door.

O

0, I1, I2, 5,   , 10, 

 

, P, P1

0,25mm²

0,50mm²

0,50mm²

1,00mm²

1,00mm²

2,50mm²

Terminal

100m.

Maximum distance

300m.

–, 3

~1, ~2, CV

P -

S-8

nstallation of S-8 call repeaters.

I

The total amount of call repeaters and
     telephones placed in the same apartment
     is three.
     For each item placed in parallel
     the section corresponding to the call wire
     must be doubled.

ind.

ind.

0

0

0

10

10

10

5

5

5

3

3

3

P1

P1

P1

TROUBLESHOOTING HINTS

INSTALLATION DIAGRAM

INSTALLATION DIAGRAM

arallel telephones installation.

P

The maximum number of telephones placed
     in the same apartment is three.
     For each telephone placed in parallel
     the section corresponding to the call wire
     must be doubled.

ections chart

S

For longer distances
     than the specified
     contact with your distributor.

ock release activation using an external push button.

L

The lock release can be activated at any moment by using an external
     push button, that must be connected between '–' and 'P' terminals
     of the sound module. This function will allows to exit from the
     building being not necessary the use of a key.

O

Nothing operates.

w

Check the output transformer voltage between SEC terminals: it should have 12 to 17Va.c. If 

not, disconnect the transformer from the installation and measure again. If it's correct now, 
it means there is a short circuit in the installation: disconnect the transformer from mains 
and check the installation.

O

Inappropriate audio level.

w

Adjust the level volumes as shown on page 3. In case of feedback, reduce the audio levels 

until feedback fade out.

O

Door open function no operates.

w

Disconnect the lock release from the sound module and short-circuit terminals ' ' and 'P': at 

that moment the output voltage between terminals 'CV' should be 12Va.c. If it's so check 
the lock release, its wiring and the wiring of the terminal 'P' from the sound module to the 
telephones. If these tests don't solve the problem, replace the door panel.

CV

CV

P

I1 I2

-

~1 ~2

TF-104

PE-295/1AL
PE-295/2AL

SEC

~

~

PRI

~

~

0

0

10

10

5

5

3

3

P1

P1

Main

T-900 or T-902

T-900

Maximum load

200mA / 48Vd.c.