DOOR PANEL INSTALLATION
LOCK RELEASE INSTALLATION
nstalling the TF-104 transformer.
I
POWER SUPPLY INSTALLATION
ock release installation.
L
Replace the protection cover once the input terminals have been wired.
It's recommended to protect the transformer by using a
thermo-magnetic circuit breaker.
If the lock release will be installed in a metal door, use a
Ø3,5mm.
drill and tap the hole. In case of wood door, use a Ø3mm. drill.
lose the door panel.
C
oor panel assembly.
D
In assemblies of a single door panel, it is ready from factory
to be mounted.
IMPORTANT:
To make these adjustments of joining several door panels, see the
document that is supplied with the door panel and follow the
steps that are described in the section" Mechanical assembly
for double door panel" and once finished the adjustments stick
the adhesive gasket (that is supplied with the push buttons
module) in the rod of joining modules.
If the door panel to installing is of more than one module it will be
necessary make some adjustments to join a door panel with
other one.
Fix the door panel by using the supplied screws.
Finish the door panel assembly by placing the closing
heads, put the head on one side and then make a slight
pressure on the other end, to its correct placement.
Install the transformer in a dry and protected place without risk of drip or water projections.
To avoid an electrical shock, neither remove the primary protection cover nor handle the connected
wire in the terminals.
The installation and handling of these equipments must be performed by
authorised personnel
and
without the power connected
.
To avoid damage, the transformer has to be firmly fixed.
M 4 x 8
3,5 x 25
DIN-7972
DIN-963
DIN 46277
The transformer can be installed on a DIN guide (3 units) simply pressing it.
To disassemble the transformer from the DIN guide, use a plain screwdriver to lever the flange as
shown on the picture.
3,5 x 25
DIN-7971
3,5 x 25
DIN-7971
To install the transformer directly on the
wall, insert the fixing flanges.
Drill two holes of
Ø6mm. and insert
the wallplugs.
Fix the transformer with the specified
screws.