golmar CD-V2PLUS/TP Instruction Manual Download Page 4

M

C

-

V2PLUS

Backbone encoder (general door panels).

Permits the installation of 

Plus

 

general door panels with the 

V2Plus

 

system, the 

V2Plus

 inner door panels 

will be connected through the 

MC-V2Plus

 multiplexer. There is an option to place a 

CE-990 Plus

 porter's 

exchange between the converter and the general door panel.

This type of installation requires a converter for each inner backbone

Installation diagrams on pages 43 to 46

.

.

2

2

1
5
9

2
6
0

3
7
C

4
8

2

2

1
5
9

2
6
0

3
7
C

4
8

General Plus door panel

BACKBONE 0

Central de conserjería

Porter's exchange

0

0

C

ancel

C

ancel

7

7

8

8

9

9

1

1

2

2

3

3

4

4

5

5

6

6

o.k.

o.k.

Porter’s

exchange

To the rest 

of the Backbones

2

CD-V2PLUS/TP

2

CD-V2PLUS/TP

2

Lock release

Lock release

General Plus door panel

3 + TP

3 + TP

Backbone encoder (Coded door panel).

This option allows the installation of 

Plus

 coded door panels 

with 

V2Plus

  monitors/telephones.  The  converter  will  be 

connected to the output of the door panel.
Another  option  is  for  us  to  place  a 

Plus

  porter's  exchange 

between the 

converter

 and the coded door panel.

This  variation  can  be  applied  with  or  without  general  door 
panels.
Installation diagram on page 42.

CD-V2PLUS/TP

FA-V2PLUS

2

2

2

1
5
9

2
6
0

3
7
C

4
8

Plus coded door panel

Central de conserjería

Porter's exchange

0

0

C

ancel

C

ancel

7

7

8

8

9

9

1

1

2

2

3

3

4

4

5

5

6

6

o.k.

o.k.

Lock release

4 + TP

Porter’s 

exchange

BACKBONE 1

Platea V2Plus Monitors

2

2

2

2

2

Riser 1

Platea V2Plus Monitors 

2

2

2

2

2

Platea V2Plus Monitors 

2

2

2

2

4 + TP

3 + TP

3 + TP

Max. 32 apartments 

Max. 32 apartments 

Max. 32 apartments

FA-V2PLUS

FA-PLUS/C

FA-PLUS/C

FA-PLUS/C

FA-V2PLUS

M

C

-

V2PLUS

2

FA-V2PLUS

2

2

MC-V2PLUS

MC-V2PLUS

2

FA-V2PLUS

2

2

2

FA-V2PLUS

V2PLUS door panel

BACKBONE 2

Riser 1

Next
Riser

Next
Riser

Terms:

Backbone
Riser: Physical cabling of the installation 
         in the same backbone (logical address).

: Logical address.

*

*

*

*

*

*

*

*

S

S

 

=Master.

S  =Slave.

M

M

M

M

M

OPERATION MODES

35

Coming from previous page

(1)

(1)

(1) Necessary the RCSH-562 connection block for 

.

4+TP installation

Summary of Contents for CD-V2PLUS/TP

Page 1: ...Protocol converter Instructions manual TCD V2PLUS TP ML rev 0112 C d 50121239 CD V2PLUS TP...

Page 2: ...anel converter multiplexer monitors telephones and the power supply connection Do always follow the enclosed information When starting the equipment for the first time or after a modification the syst...

Page 3: ...aximum distance between the power supply and converter 50m with a wire section of 1 5mm Use Golmar RAP 2150 cable in the V2Plus system monitors telephones or call repeaters and 120 monitors telephones...

Page 4: ...ill be connected to the output of the door panel Another option is for us to place a Plus porter s exchange between the converter and the coded door panel This variation can be applied with or without...

Page 5: ...nfiguration dip switch Plus Bus connection block TP video V2Plus Bus connection block Label 36 Install the converter in a dry and protected place free from the risk of drip or water projections To avo...

Page 6: ...igured as Slaves To reset the converter switch to ON and then set to OFF after a Short circuit or programming error Set to ON if there are distributors in the backbone single user or multi user or the...

Page 7: ...or panel Cancel If there are more converters repeat the previous steps introducing a different backbone code for each of them If during one of these processes the red LED on the converter switches on...

Page 8: ...ith independent more common wires only use the common wires separate and do not connect the independent ones 1 access door panel up to 3 access door panel with MC V2PLUS multiplexer Up to 32 monitors...

Page 9: ...NT if the installation includes multiplexers in daisy chain with monitors B W Maximum distance between door panel converter and multiplexer 150m Maximum distance between multiplexer in daisy chain and...

Page 10: ...15m 15m 15m 15m 15m 15m 50m 100m 100m 150m 35m 70m 100m 200m 35m 70m 100m 26m 46m 67m 67m 16m 33m 67m 100m 16m 33m 67m Use Golmar RAP 2150 cable for new installations Several accesses and risers with...

Page 11: ...nel STADIO INOX ROCK 230 110 0 SEC PRI Main FA PLUS C ver 938072 D3 BUS IN PA PB BUS OUT HZ F Linea D4L V2Plus BUS IN PA PB BUS OUT HZ BUS D2 D1 BUS D4 Platea V2Plus Sw2 Platea V2Plus Sw2 Configuring...

Page 12: ...ser MC V2PLUS 1 Insert the end of line 120 resistor in the last distributor Setting the end of line in the last monitor SEC PRI 0 110 230 Main FA V2PLUS BACKBONE 1 IMPORTANT For the configuration and...

Page 13: ...BUS MC V2PLUS BUS IN PA PB BUS OUT HZ BUS BUS D Platea V2Plus F Linea D1L V2Plus Sw2 Main SEC PRI 0 110 230 Main FA V2PLUS BACBONE 250 SW1 6 M Master S S Slave M 1 S Door panel V2Plus Next distributo...

Page 14: ...L 2 PL 3 Next Riser M IMPORTANT To configure and to program each equipment see the appropiate instruction book Main Main General door panel Communication R ACTIVATED M Next distributor INSTALLATION DI...

Page 15: ...tor Setting the end of line in the last monitor To the next door panel Main Main M Master S Slave S General door panel Communication R DEACTIVATED Next Riser Next distributor BACKBONE 0 BUS CD V2PLUS...

Page 16: ...tly followed see page 38 Check that the voltage in the BUS terminal of the converter is 23 to 25 5 Vdc If that is not the case disconnect the affected terminal wires and check that there are no short...

Reviews: