golmar CD-V2PLUS/TP Instruction Manual Download Page 2

33

INTRODUCTION

STARTING RECOMMENDATIONS

INDEX

First of all we would like to thank and congratulate you for the purchase of this product manufactured by

The commitment to reach the satisfaction of our customers is stated through the ISO-9001 certification 
and for the manufacturing of products like this one.

Its advanced technology and exacting quality control will do that customers and users enjoy with the 
legion of features this system offers To obtain the maximum profit of these features and a properly wired 
installation, we kindly recommend you to expend a few minutes of your time to read this manual.

 

Golmar.

O

O
O
O

O

O
O

The installation and handling of this equipment must be performed by 

authorised personnel

Install or modify the equipment 

without the power connected

Do not use excessive force when tightening the converter connection block screws

Before connecting the system, check the connections between door panel, converter, multiplexer, 
monitors, telephones and the power supply connection. Do always follow the enclosed information
When starting the equipment for the first time, or after a modification, the system will remain inactive 
for around 45 seconds due to the initial busy channel time
Use Golmar 

cable in the 

system

.

O

.

.

The entire installation must be at least 

40 cm.

 away from any 

other installation

.

.

.

RAP-2150

 

V2Plus

 

.

Do always follow the enclosed information.

Introduction........................................................................................................................33
Index .................................................................................................................................33
Starting recommendations....................................................................................................33
Safety precautions ...............................................................................................................34
System characteristics ..........................................................................................................34
Operation modes ..........................................................................................................34-35
Description.........................................................................................................................36
Installation .........................................................................................................................36

.............................................................................................................38

Replacement

.....................................................................................................................39

Minimum requirements

.............................................................................................39-40

Installation of replacement

.................................................................................................

Cable, sections and distances chart (one access and one riser)

.......................................40

Cable, sections and distances chart (several accesses and risers)

....................................41

Installation diagrams ...............................................................................................................

Coded panel ....................................................................................................................42
General door panel (without coaxial cable) .....................................................................43-44
General door panel (with coaxial cable)..........................................................................45-46

Troubleshooting hints...........................................................................................................47
Notes ...........................................................................................................................48-50
Compliance .......................................................................................................................51

Configuration dip switch.......................................................................................................37
Configuration jumper (End of line resistor) ..............................................................................37

rogramming the converter

Autodiagnostic Leds
P

 (Backbone code) ..........................................................................38

Summary of Contents for CD-V2PLUS/TP

Page 1: ...Protocol converter Instructions manual TCD V2PLUS TP ML rev 0112 C d 50121239 CD V2PLUS TP...

Page 2: ...anel converter multiplexer monitors telephones and the power supply connection Do always follow the enclosed information When starting the equipment for the first time or after a modification the syst...

Page 3: ...aximum distance between the power supply and converter 50m with a wire section of 1 5mm Use Golmar RAP 2150 cable in the V2Plus system monitors telephones or call repeaters and 120 monitors telephones...

Page 4: ...ill be connected to the output of the door panel Another option is for us to place a Plus porter s exchange between the converter and the coded door panel This variation can be applied with or without...

Page 5: ...nfiguration dip switch Plus Bus connection block TP video V2Plus Bus connection block Label 36 Install the converter in a dry and protected place free from the risk of drip or water projections To avo...

Page 6: ...igured as Slaves To reset the converter switch to ON and then set to OFF after a Short circuit or programming error Set to ON if there are distributors in the backbone single user or multi user or the...

Page 7: ...or panel Cancel If there are more converters repeat the previous steps introducing a different backbone code for each of them If during one of these processes the red LED on the converter switches on...

Page 8: ...ith independent more common wires only use the common wires separate and do not connect the independent ones 1 access door panel up to 3 access door panel with MC V2PLUS multiplexer Up to 32 monitors...

Page 9: ...NT if the installation includes multiplexers in daisy chain with monitors B W Maximum distance between door panel converter and multiplexer 150m Maximum distance between multiplexer in daisy chain and...

Page 10: ...15m 15m 15m 15m 15m 15m 50m 100m 100m 150m 35m 70m 100m 200m 35m 70m 100m 26m 46m 67m 67m 16m 33m 67m 100m 16m 33m 67m Use Golmar RAP 2150 cable for new installations Several accesses and risers with...

Page 11: ...nel STADIO INOX ROCK 230 110 0 SEC PRI Main FA PLUS C ver 938072 D3 BUS IN PA PB BUS OUT HZ F Linea D4L V2Plus BUS IN PA PB BUS OUT HZ BUS D2 D1 BUS D4 Platea V2Plus Sw2 Platea V2Plus Sw2 Configuring...

Page 12: ...ser MC V2PLUS 1 Insert the end of line 120 resistor in the last distributor Setting the end of line in the last monitor SEC PRI 0 110 230 Main FA V2PLUS BACKBONE 1 IMPORTANT For the configuration and...

Page 13: ...BUS MC V2PLUS BUS IN PA PB BUS OUT HZ BUS BUS D Platea V2Plus F Linea D1L V2Plus Sw2 Main SEC PRI 0 110 230 Main FA V2PLUS BACBONE 250 SW1 6 M Master S S Slave M 1 S Door panel V2Plus Next distributo...

Page 14: ...L 2 PL 3 Next Riser M IMPORTANT To configure and to program each equipment see the appropiate instruction book Main Main General door panel Communication R ACTIVATED M Next distributor INSTALLATION DI...

Page 15: ...tor Setting the end of line in the last monitor To the next door panel Main Main M Master S Slave S General door panel Communication R DEACTIVATED Next Riser Next distributor BACKBONE 0 BUS CD V2PLUS...

Page 16: ...tly followed see page 38 Check that the voltage in the BUS terminal of the converter is 23 to 25 5 Vdc If that is not the case disconnect the affected terminal wires and check that there are no short...