CALIBRATION OF GYROSCOPIC
SENSOR
16
If EDM01 tends to turn when commanded forward, it might be necessary to
recalibrate the sensors that control straight movement.
Connect remote control to the EDM using USB cable.
Turn EDM ON.
Turn remote control ON.
Place EDM on level surface.
On the remote control, press and hold ON/OFF button followed by button “10”
until green and red light flash in alternate sequence.
Wait until calibration is confirmed – this is displayed by multiple red or green light
signals.
Once red or green light is flashing, release both buttons.
If green light comes on, the calibration process was successful.
Disconnect USB cable and switch both the EDM01 and the remote control OFF.
When you turn both units back ON, they will be ready for use.
If the calibration process was unsuccessful (red light comes on instead of green),
turn both units OFF, check the USB cable (or change it) and repeat the process.