Normal:
High speed: Approximately
60 to 75 ohm
Low speed: Approximately
110 to 125 ohm
7-16
COMPONENTS
TEST PROCEDURES
RESULTS
Normal:
Momentarily infinite and
then soon reach 10 Mega.
ohms
Normal: Infinite.
Normal:Continuity.
Abnormal: Below 100
ohms
Normal: Infinite.
Abnormal: Below 100
ohms
1. Remove wire leads.
2. Measure resistance. (ohm meter scale: Rx1000)
• Terminal to terminal
• Terminal to case
1. Measure continuity. Forward.
(ohm meter scale: Rx1000)
2. Measure continuity. Reverse.
(ohm meter scale: Rx1000)
CAPACITOR
DIODE
Some inexpensive ohm
meters may indicate
infinite resistance in
both directions.
1. Measure continuity. (ohm meter scale: Rx1)
2. Remove the lead wires and operate oven
at power level 1 through power level 10.
RELAY 7
1. Remove wire leads.
2. Measure resistance. (ohm meter scale: Rx1)
High speed: Blue and Black wire
Low speed: Blue and White wire
VENTILATION MOTOR
Power
Level
Open
Close
1
2
3
4
5
6
7
8
9
10
4 Sec
6 Sec
8 Sec
10 Sec
12 Sec
14 Sec
16 Sec
18 Sec
20 Sec
22 Sec
18 Sec
16 Sec
14 Sec
12 Sec
10 Sec
8 Sec
6 Sec
4 Sec
2 Sec
0 Sec
LGE Internal Use Only
Copyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Summary of Contents for MVH1670ST