5-15
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Abnormal
Defective high
voltage
transformer.
Replace high
voltage
transformer.
Normal
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and
check continuity
of relay 2.
(Operate the unit)
Check high vol-
tage transformer
Output is full power
when you set lower
power level.
Abnormal.
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Normal
Check high vol-
tage capacitor.
Abnormal
Defective high
voltage diode.
Replace high
voltage diode.
Normal
Check high vol-
tage diode.
Abnormal
Defective
magnetron.
Replace
magnetron.
Check
magnetron.
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.
(Display operates properly)
NOTE : • Make sure the wire leads are in the correct position.
• When removing the wire leads from the parts, be sure to grasp the connector, not the wires.
• When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
Summary of Contents for MA2120B
Page 27: ...6 2 13552A 13213A 13352A 13581A 13720D 13806D 14970A 14026A 13536A DOOR PARTS ...
Page 28: ...6 3 24781M 23506A 23572A 268711 WTP018 23550D CONTROLLER PARTS ...
Page 30: ...6 5 56912B 43500A 44510A 466003 466001 466002 55262A 43501A WSZ085 LATCH BOARD PARTS ...
Page 32: ...6 7 63302L 63303L 65006B 948501 63302R 56170D WSZ002 WTT021 63303R BASE PLATE PARTS ...
Page 41: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 42: ...8 2 PRINTED CIRCUIT BOARD ...