POWER SUPPLY 
- Nominal line voltage : 117, 234 V (switchable). 
- Input voltage range : +/- 10 %. 
- Maximum power consumption : 2000 W. 
- Power used in standby : 120 W. 
- 8 toroidal transformers, 4 separated power supply. 
 
GROUNDING 
- Separated ground and earth. 
- Floating chassis connected to mains earth. 
- Possible link for optionally connecting both. 
 
SAFETY FEATURES 
- AC voltage fuse : min 10 A slow-blow for 220 V / 16 A slow-blow for 110 V. 
 
FRONT PANEL CONTROLS 
- 2 control keys. 
- Display to show Input attenuation or inside temperature. 
- Led display for temperature, DC offset or HF protection. 
- Led display for Power on, operating mode. 
- Led display for Power on, standby mode. 
 
REAR PANEL CONNECTORS AND CONTROLS 
- Power cord: universal socket 3 lugs. 
- Main fuse (10A slow-blow 110V / 16 A slow-blow 220 V). 
- Green-yellow AC earth binding post. 
- Black signal ground binding post. 
- Output speaker : 3 X 5 ways post in parallel. 
- Output speaker 3 x Coaxial connectors in parallel. 
- Input connector RCA. 
- Input connector XLR for balanced input. 
 
SIZE AND WEIGHT 
- 44 cm (17") W x 51 cm (20") D  x 23.5 cm (9.25") H. 
- Weight : 75 kg net. 
 
WARRANTY 
- 3 years parts and labor. 

Summary of Contents for MIMESIS 29.4M MILLENNIUM EDITION

Page 1: ...GOLDMUND MIMESIS 29 4M MILLENNIUM EDITION POWER AMPLIFIER...

Page 2: ...er made for professional and domestic uses Please take some time to read this manual It may provide you with useful information to make your pleasure of listening to the Mimesis 29 4M even higher ATTE...

Page 3: ...of it equipment sensitive to temperature Due to its weight and to maximize the effect of the built in Mechanical Grounding construction the MIMESIS 29 4M is better located on the floor But other very...

Page 4: ...reasons To get the best sound of the amplifier avoid any multiple plug or extension cord Connect the interconnects between the preamp and each power amp You may either use the RCA female socket or the...

Page 5: ...ssing it twice you reach the Auto Power Mode adjustment You may now activate the Auto Power Mode On or Off by pressing the left key In Auto Power mode the amp is turned on automatically when receiving...

Page 6: ...has been powered off for some time the optimum sound quality is only reached after several minutes The critical circuits have to warm up to around 55 degrees Celsius 131 degrees Fahrenheit When the am...

Page 7: ...e sonic improvement when the proper grounding is found is obvious and worth the try 7 SAFETY FEATURES The GOLDMUND MIMESIS 29 4 amplifier provides sophisticated features to protect the amplifier and t...

Page 8: ...the temperature has reached such a level before operating the amp again Protection against short circuits If one output is short circuited by accident and the current becomes too high the AC fuse may...

Page 9: ...ustable input sensitivity on the back panel Input impedance 10 52 kOhms GROUP DELAY Propagation delay 100 ns stable with frequency from DC to 200 kHz DISTORTION Figures valid for all levels from 0 to...

Page 10: ...Display to show Input attenuation or inside temperature Led display for temperature DC offset or HF protection Led display for Power on operating mode Led display for Power on standby mode REAR PANEL...