POWER SUPPLY 
- Nominal line voltage : 117, 234 V (switchable). 
- Input voltage range : +/- 10 %. 
- Maximum power consumption : 1200 W. 
- Power used in standby : 100 W. 
- 4 toroidal transformers, 4 separated power supply. 
 
GROUNDING 
- Separated ground for each channel. 
- Floating chassis connected to mains earth. 
- Switch for optionally connecting both. 
 
SAFETY FEATURES 
- AC voltage fuse : min 10 A slow-blow for 220 V / 16 A slow-blow for 110 V. 
 
FRONT PANEL CONTROLS 
- 2 POWER keys. 
- Protection against accidental power off. 
 
REAR PANEL CONNECTORS AND CONTROLS 
- Power cord: universal socket 3 lugs. 
- Main fuse (16A slow-blow 110V / 10 A slow-blow 220 V). 
- Green-yellow AC earth binding post. 
- Black signal ground binding post. 
- Output speaker 2 X 5 ways post. 
- Input connector RCA (right and left). 
- Input connector XLR for balanced input (right and left). 
 
SIZE AND WEIGHT 
- 44 cm (17") W x 44 cm (17") D x 17 cm (7") H. 
- Weight : 45 kg net. 
 
WARRANTY 
- 3 years parts and labor. 

Summary of Contents for MIMESIS 28

Page 1: ...GOLDMUND MIMESIS 28 POWER AMPLIFIER...

Page 2: ...or professional and domestic uses Please take some time to read this manual It may provide you with useful information to make your pleasure of listening to the Mimesis 28 even higher ATTENTION No con...

Page 3: ...better located on the floor But other very strong supports can also be used if they offer a very rigid transmission with the floor 3 LINE VOLTAGE ADJUSTMENT A voltage selection is provided inside the...

Page 4: ...trical 4 wire cable always maintain the ground earth switch to Link lever to the black post or you may destroy your amplifier Connect the speaker cables to the red and black terminals accessible in th...

Page 5: ...ly all the combinations before picking the right one If your preamp has an absolute phase inverter this will interfere too If it has not don t forget the result will depend of the source most of the r...

Page 6: ...try to detect why the temperature has reached such a level before operating the amp again Protection against short circuits If one output is short circuited by accident and the current becomes too hi...

Page 7: ...0 1 dB 0 300 kHz 1 dB 0 800 kHz 3 dB 0 2 MHz INPUT SENSITIVITY Nominal level 1 45 V RMS Voltage Gain 29 Input impedance 52 kOhms GROUP DELAY Propagation delay 140 ns stable with frequency from DC to 2...

Page 8: ...use min 10 A slow blow for 220 V 16 A slow blow for 110 V FRONT PANEL CONTROLS 2 POWER keys Protection against accidental power off REAR PANEL CONNECTORS AND CONTROLS Power cord universal socket 3 lug...

Reviews: