1 - UNPACKING 
 
 
You will find in the GOLDMUND MIMESIS 28 box : 
- The amplifier 
- The power cord 
- This manual 
- Spare fuses. 
Please keep the packaging in case you need to transport the amplifier at a later date 
or if you have to send it for maintenance. 
 
 
 
 
 
2 – CHOICE OF AMPLIFIER LOCATION AND COOLING 
 
 
The GOLDMUND MIMESIS 28 amplifier, as all high quality amplifiers generates a 
large amount of heat. 
It is mandatory to allow a proper cooling of the heat sinks. Avoid any location which is 
not properly vented and avoid to put on top of it equipment sensitive to temperature. 
 
Due to its weight, and to maximize the effect of the built-in "Mechanical Grounding" 
construction, the MIMESIS 28 is better located on the floor. But other very strong 
supports can also be used, if they offer a very rigid transmission with the floor. 
 
 
 
 
 
3 – LINE VOLTAGE ADJUSTMENT 
 
 
A voltage selection is provided inside the amplifier. 
If your line voltage is not adapted to the voltage indicated on the serial plate of the 
amplifier, please consult your local GOLDMUND dealer for internal adjustment. 
 
ATTENTION : On the 220V position, the GOLDMUND MIMESIS 28 amplifier will 
function properly for main line voltage in between 200V and 240V. On the 110V 
position, the main line must deliver between 105 and 125V. If your main line is 
usually out of these tolerances, please consult your GOLDMUND dealer. 
 
 
 
Please check the value of the main line fuse. This fuse is located on the back panel 
of the amplifier, above the two power cord receptacles. 
Use a 5A delayed fuse for 220V and a 8A delayed fuse for 110V. 
 

Summary of Contents for MIMESIS 28

Page 1: ...GOLDMUND MIMESIS 28 POWER AMPLIFIER...

Page 2: ...or professional and domestic uses Please take some time to read this manual It may provide you with useful information to make your pleasure of listening to the Mimesis 28 even higher ATTENTION No con...

Page 3: ...better located on the floor But other very strong supports can also be used if they offer a very rigid transmission with the floor 3 LINE VOLTAGE ADJUSTMENT A voltage selection is provided inside the...

Page 4: ...trical 4 wire cable always maintain the ground earth switch to Link lever to the black post or you may destroy your amplifier Connect the speaker cables to the red and black terminals accessible in th...

Page 5: ...ly all the combinations before picking the right one If your preamp has an absolute phase inverter this will interfere too If it has not don t forget the result will depend of the source most of the r...

Page 6: ...try to detect why the temperature has reached such a level before operating the amp again Protection against short circuits If one output is short circuited by accident and the current becomes too hi...

Page 7: ...0 1 dB 0 300 kHz 1 dB 0 800 kHz 3 dB 0 2 MHz INPUT SENSITIVITY Nominal level 1 45 V RMS Voltage Gain 29 Input impedance 52 kOhms GROUP DELAY Propagation delay 140 ns stable with frequency from DC to 2...

Page 8: ...use min 10 A slow blow for 220 V 16 A slow blow for 110 V FRONT PANEL CONTROLS 2 POWER keys Protection against accidental power off REAR PANEL CONNECTORS AND CONTROLS Power cord universal socket 3 lug...