- Nominal line voltage : 117, 234 V (internally switchable). 
- Input voltage range : +/- 10 %. 
- Maximum power consumption : 700 W. 
- Power used in standby : 70 W. 
- 4 toroidal transformers, 3 separated power supply. 
 
GROUNDING 
- Chassis connected to mains earth. 
 
SAFETY FEATURES 
- AC voltage fuse : min 5 A slow-blow for 220 V / 8 A slow-blow for 110 V. 
- Built-in detection for HF and DC with speaker disconnection. 
 
FRONT PANEL CONTROLS 
- Power key. 
- 3 control Leds (Safety, Power, and Digital Lock) 
 
REAR PANEL CONNECTORS AND CONTROLS 
- Power cord: universal socket 3 lugs. 
- Main fuse (8 A slow-blow 110V / 5 A slow-blow 220 V). 
- Green-yellow AC earth binding post. 
- Earth connection switch to connect earth and signal ground (link-float). 
- Output speaker 2 X 5 ways post. 
- Output speaker Coaxial for Goldmund Speaker cable. 
- Analogue Input connectors : RCA and XLR for balanced input.  
- Digital Input connector RCA for input and output. 
- Digital input channel selection switch. 
- Input attenuator : -9, -6, -3, 0, +3, +6, +9dB 
 
SIZE AND WEIGHT 
- 22 cm (17") W x 44 cm (17") D x 17 cm (7") H. 
- Weight : 25 kg net. 
 
WARRANTY 
- 3 years parts and labor. 

Summary of Contents for MIMESIS 18.4

Page 1: ...GOLDMUND MIMESIS 18 4 POWER AMPLIFIER...

Page 2: ...or professional and domestic uses Please take some time to read this manual It may provide you with useful information to make your pleasure of listening to the Mimesis 18 4 even higher ATTENTION No c...

Page 3: ...ther very strong supports can also be used if they offer a very rigid transmission with the floor 3 LINE VOLTAGE ADJUSTMENT A voltage selection is provided inside the amplifier accessible by an openin...

Page 4: ...e polarity The amplifier is non inverting in phase 5 AMPLIFIER CONTROLS On the front panel of the GOLDMUND MIMESIS 18 4 amplifier you will find only the power key and 3 Led To start playing the amplif...

Page 5: ...y to again increase the sonic quality of your speakers by reverting the polarity of the speaker cable amp termination But since the line phase and the speaker polarity interfere to each other you have...

Page 6: ...erconnects If the ground connection becomes loose there is a big danger of oscillation Warranty is voided if this occurs Never run the input and output speaker cables parallel If an oscillation of too...

Page 7: ...ENSITIVITY Nominal level 1 45 V RMS Voltage Gain 29 Input impedance 52 kOhms GROUP DELAY Propagation delay 140 ns stable with frequency from DC to 200 kHz DISTORTION Figures valid for all levels from...

Page 8: ...s Safety Power and Digital Lock REAR PANEL CONNECTORS AND CONTROLS Power cord universal socket 3 lugs Main fuse 8 A slow blow 110V 5 A slow blow 220 V Green yellow AC earth binding post Earth connecti...

Reviews: