background image

 
 
If used with an analogue signal, connect the interconnect between the preamp and 
each power amp. Check the input switch is in the analogue position. 
You may either use the analogue input RCA female socket or the XLR. The XLR 
socket, especially useful in professional installations, is wired as follows : 
 
    1 - Grounding, Shielding. 
    2 - Hot. 
    3 - Cold. 
 

Attention : if you want to use a symmetrical 4 wire cable, always maintain the 
ground/earth switch to "Link" or you may destroy your amplifier. 

 
When used with a digital input signal, connect the digital input cable to the digital 
input and switch the input switch to digital. Since a digital Spdif cable carries 2 
channels you may link the digital output to the next amplifier to transfer the second 
channel. 
 
Connect the speaker cable to one of the red and black terminals in the back of the 
amplifier or, if you use a Goldmund High Definition Speaker Cable, to the coaxial 
connector.  
The 2 separate outputs are connected internally in parallel.  
You may notice that the ground of the input plug and the black speaker terminal are 
the same polarity. The amplifier is non-inverting in phase. 
 
 
 

5 – AMPLIFIER CONTROLS 

 
 
On the front panel of the GOLDMUND MIMESIS 18.4 amplifier you will find only the 
power key and 3 Led. 
 
To start playing the amplifier, switch the key to ON. The amplifier is immediately 
operative, without delay and the central green Led indicates it is operating normally.  
The Mimesis 18.4 is using a signal-sensing auto-start circuit. If no modulation is 
received by the power amp for approximately 20 minutes, the power amp will go off 
and the green central Led will only flash regularly to indicate that the amp is ON and 
ready to restart. 
If a signal is applied to the input (analogue or digital), the amp will start working again 
and the green Led will stay on. 
 
In large system with several amplifiers connected, you may have problem when 
applying a signal if all power amps start simultaneously, triggering the house breaker. 
To avoid it, each amp may have a small different delay adjusted to make them start 
in sequence and avoid the problem. To adjust each amp differently, disconnect the 
amplifier from AC, open the bottom removable plate, and using a small screwdriver, 
turn the small rotary switch accessible on the visible printed circuit. Just set each 
amp to a different position of the switch. 

Summary of Contents for MIMESIS 18.4

Page 1: ...GOLDMUND MIMESIS 18 4 POWER AMPLIFIER...

Page 2: ...or professional and domestic uses Please take some time to read this manual It may provide you with useful information to make your pleasure of listening to the Mimesis 18 4 even higher ATTENTION No c...

Page 3: ...ther very strong supports can also be used if they offer a very rigid transmission with the floor 3 LINE VOLTAGE ADJUSTMENT A voltage selection is provided inside the amplifier accessible by an openin...

Page 4: ...e polarity The amplifier is non inverting in phase 5 AMPLIFIER CONTROLS On the front panel of the GOLDMUND MIMESIS 18 4 amplifier you will find only the power key and 3 Led To start playing the amplif...

Page 5: ...y to again increase the sonic quality of your speakers by reverting the polarity of the speaker cable amp termination But since the line phase and the speaker polarity interfere to each other you have...

Page 6: ...erconnects If the ground connection becomes loose there is a big danger of oscillation Warranty is voided if this occurs Never run the input and output speaker cables parallel If an oscillation of too...

Page 7: ...ENSITIVITY Nominal level 1 45 V RMS Voltage Gain 29 Input impedance 52 kOhms GROUP DELAY Propagation delay 140 ns stable with frequency from DC to 200 kHz DISTORTION Figures valid for all levels from...

Page 8: ...s Safety Power and Digital Lock REAR PANEL CONNECTORS AND CONTROLS Power cord universal socket 3 lugs Main fuse 8 A slow blow 110V 5 A slow blow 220 V Green yellow AC earth binding post Earth connecti...

Reviews: