Compatibility
The T-Cell-5 electrolytic chlorine generator cell is designed to work with the Aqua Trol Above-
Ground Pool Automation, PCP 28593. The kit includes a Turbo Cell, flow switch, and 5 cm (2")
cell unions for installation.
Plumbing
Turbo Cell
The Turbo Cell (used for chlorine generation) should be plumbed AFTER the filter and heater. If
installed on a pool/spa combination system, the cell should be plumbed BEFORE the pool/spa
return valve in order to allow proper chlorination of both the pool and the spa. Refer to plumbing
diagram below:
{Diagram}
The cell may be mounted vertically or horizontally, and water can move in either direction through
the cell. Install using the
5 cm (2")
unions provided. Tighten unions
BY HAND
for a watertight
seal. For systems under
5 cm (2")
plumbing, use adaptors (provided by installer).
Flow Switch
The flow switch must be plumbed in the same section of plumbing as the Turbo Cell. The flow
switch is a safety device that ensures that water is flowing through the cell before the Aqua Trol
Above-Ground Pool Automation starts to generate chlorine. Failure to properly install the flow
switch can result in explosive gases accumulating in the pool plumbing system. There must be at
least a
12" (30cm)
straight pipe run before (upstream) the flow switch. To ensure proper operation,
verify that the arrow on the flow switch points in the direction of water flow.