Maintaining the Aqua Trol Above-Ground Pool Automation

 

To maintain maximum performance, it is recommended that you open and visually inspect the cell 
every 3 months or after cleaning your filter. The Aqua Trol Above-Ground Pool Automation 
will remind you to do this by flashing the "Inspect Cell" LED after approximately 500 hours of 
operation. After you inspect the cell (and clean, if necessary) press the small "diagnostic" button 
next to the display for 3 seconds to stop the flashing "Inspect Cell" LED and start the timer for the 
next 500 hours inspection period. 

 

The Aqua Trol Above-Ground Pool Automation elecTrol ytic cell has a self cleaning feature 
incorporated into the electronic control’s logic. In most cases, this self cleaning action will keep 
the cell working at optimum efficiency. In areas where water is hard (high mineral content)and in 
pools where the water chemistry has been allowed to get "out of balance", the cell may require 
periodic cleaning. The "Inspect Cell" LED will indicate if cell efficiency is decreased and servicing 
is necessary. If the "Inspect Cell" LED remains on after a thorough cleaning, the cell may be worn 
and require replacement. When replacing the cell, only use replacement cells having a label that 
clearly states that it is a replacement cell for the Aqua Trol Above-Ground Pool Automation, 
REGISTRATION NUMBER 28593, PEST CONTROL PRODUCT ACT. 

The life expectancy of the elecTrol ytic cell is 10,000 hours under normal use 

conditions. 

Servicing and Cleaning the Aqua Trol Above-Ground Pool Automation cell

 

Turn off power to the Aqua Trol Above-Ground Pool Automation before removing the elecTrol 
ytic cell. Once removed, look inside the cell and inspect for scale formation (light colored

 

crusty or flaky deposits) on the plates and for any debris which has passed through the filter and

 

caught on the plates. If no deposits are visible, reinstall. If deposits are seen, use a high pressure 
garden hose and try to flush the scale off. If this is not successful, use a plastic or wood tool (do 
not use metal as this will scratch the coating off the plates) and scrape deposits off of the plates. 
Note that a build upon the cell indicates that there is an unusually high calcium level in the pool 
(old pool water is usually the cause). If this is not corrected, you can expect to have to periodically 
clean the cell. The simplest way to avoid this is to bring the pool chemistry to the recommended 
levels as specified.

 

 

Mild Acid Washing: Use only in severe cases where flushing and scraping will not remove the 
majority of deposits. To acid wash, turn off power to Aqua Trol Above-Ground Pool Automation. 
Remove cell from piping. In a clean plastic container, mix a 4:1 solution of water to muriatic acid 
(3.78 liters (one gallon) of water to one liter (quart) of muriatic acid). ALWAYS POUR ACID INTO 
WATER - NEVER POUR WATER INTO ACID. Be sure to wear rubber gloves

 

and appropriate eye protection. The level of the solution in the container should just reach the top 
of the cell so that the wire harness compartment is NOT submerged. It may be helpful to coil the 
wiring before immersing the cell. The cell should soak for a few minutes and then rinse with a

 

high pressure garden hose. If any deposits are still visible, repeat soaking and rinsing. Replace 
cell and inspect again periodically.

 

 

Winterizing

 

The Aqua Trol Above-Ground Pool Automation elecTrol ytic cell and flow detection switch will 
be damaged by freezing water just as your pool plumbing would. In areas of the country which 
experience severe or extended periods of freezing temperatures, be sure to drain all water from

 

the pump, filter, and supply and return lines before any freezing conditions occur. The electronic

 

control is capable of withstanding any winter weather and should not be removed.

 

 

Spring Start-up

 

DO NOT turn the Aqua Trol Above-Ground Pool Automation on until the pool water chemistry 
has been brought to the proper levels. This information can be found on page 2.

 

Summary of Contents for aqua trol

Page 1: ...NTROLPRODUCTS ACT This cell must only be used on this model of chlorine generating device KEEP OUT OF REACH OF CHILDREN Read the Label the Installation and Operation Manual of the Aqua Trol Above Ground Pool Automation before using Hayward Pool Products Canada Inc 2880 Plymouth Drive Oakville ON L6H 5R4 1 888 238 7665 POOL ...

Page 2: ...that the panels are not removed on the control when attaching cables Turbo Cell Refer to the diagrams below for proper location of each control s plug in location Flow Switch Refer to the diagrams below for proper location of each control s plug in location Ensure that the connector catch snaps in order to provide a reliable connection Diagram Diagram ...

Page 3: ...tically or horizontally and water can move in either direction through the cell Install using the 5 cm 2 unions provided Tighten unions BY HAND for a watertight seal For systems under 5 cm 2 plumbing use adaptors provided by installer Flow Switch The flow switch must be plumbed in the same section of plumbing as the Turbo Cell The flow switch is a safety device that ensures that water is flowing t...

Page 4: ...chlorine per day For swimming pools a range of 1 0 3 0 ppm of free available chlorine must be maintained KEEP OUT OF REACH OF CHILDREN WARNING Operating Aqua Trol Above Ground Pool Automation without water flow through the cell can cause a build up of flammable gases which can result in FIRE OR EXPLOSION Do not use this device with bromide products READ THE LABEL AND ATTACHED MANUAL BEFORE USING R...

Page 5: ...consult a physician before entering a pool Disconnect all AC power during installation A green colored terminal marked Earth Ground is located inside the wiring compartment To reduce the risk of electric shock this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying the ...

Page 6: ...e of Contents OPERATION The Aqua Trol Above Ground Pool Automation 1 Recommended water parameters 1 Controls 6 Maintenance 8 INSTALLATION Mounting 9 Plumbing 10 Wiring 11 TROUBLESHOOTING Troubleshooting 13 WARRANTY Warranty 15 ...

Page 7: ...ation required to properly sanitize a pool varies depending upon bather load rainfall temperature and the pool s cleanliness The cell may be mounted directly to the pool return jet The electrical connections are made via 120V 15A straight blade linecord and receptacle Recommended water parameters As with any pool it is important that you maintain chemical makeup of the pool water The table on the ...

Page 8: ...e dissolved into the water If the Si is above 0 2 scaling and staining will occur Use the equation and chart below to determine the saturation index Si pH Ti Ci Ai 12 1 o C o F Ti Calcium Hardness Ci Total Alkalinity Ai 12 53 3 16 60 4 19 66 5 24 76 6 29 84 7 34 94 8 39 103 9 75 100 125 150 200 250 300 400 600 800 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 4 2 5 75 100 125 150 200 250 300 400 600 800 1 9 2...

Page 9: ...all This loss is due primarily to the addition of water because of splashing backwashing or draining because of rain Salt is not lost due to evaporation Type of Salt to Use It is important to use only sodium chloride NaCl that is 99 pure This is common food quality or water softener salt It is usually available at building supply stores in 20kg 40kg 44 88 lbs bags labeled Coarse Solar salt Do not ...

Page 10: ...000 51 110 67 147 83 183 100 220 117 257 133 293 150 330 1 200 46 100 61 133 76 167 91 200 106 233 121 267 136 300 1 400 41 90 55 120 68 150 82 180 95 210 109 240 123 270 1 600 36 80 48 107 61 133 73 160 85 187 97 213 109 240 1 800 32 70 42 93 53 117 64 140 74 163 85 187 95 210 2 000 27 60 36 80 45 100 55 120 64 140 73 160 82 180 2 200 23 50 30 67 38 83 45 100 53 117 61 133 68 150 2 400 18 40 24 5...

Page 11: ...0 0 7 0 9 1 1 1 4 1 6 1 8 2 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 0 5 0 6 0 8 0 91 1 1 1 2 1 4 1 0 1 3 1 7 2 0 2 4 2 7 3 0 0 2 0 3 0 4 0 45 0 54 0 64 0 68 0 5 0 7 0 8 1 0 1 2 1 4 1 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Stabilizer Cyanuric Acid Always check stabilizer cyanuric acid when checking salt These levels will most likely decline together Use the chart below to determine how much stabilizer must be added t...

Page 12: ...etting for the entire filtering pumping cycle SUPER CHLORINATE When you have an abnormally high bather load a large amount of rain a cloudy water condition or any other condition which needs a large amount of purification to be introduced put the main switch in the SUPER CHLORINATE position This electronically super chlorinates shocks the water for 24 hours filter pump must be on during this time ...

Page 13: ...rature in degrees Fahrenheit With the temperature displayed move the main switch from AUTO to SUPER CHLORINATE to AUTO The temperature display will instantly change to degrees Celsius and the salt display will switch to grams liter Repeat this process to switch back to English units ppm and Fahrenheit Operation By understanding how the Aqua Trol Above Ground Pool Automation operates you ll be sure...

Page 14: ...ble reinstall If deposits are seen use a high pressure garden hose and try to flush the scale off If this is not successful use a plastic or wood tool do not use metal as this will scratch the coating off the plates and scrape deposits off of the plates Note that a build upon the cell indicates that there is an unusually high calcium level in the pool old pool water is usually the cause If this is...

Page 15: ...uick trouble free transfer to the Aqua Trol Above Ground Pool Automation Mounting the Aqua Trol Above Ground Pool Automation Control The Aqua Trol Above Ground Pool Automation is contained in a raintight enclosure that is suitable for outdoor mounting The control must be mounted a minimum of 2 meters 5 ft horizontal distance or more if local codes require from the pool The control is designed to m...

Page 16: ... flow switch however it is very important that the cell be mounted vertically directly below the return jet in order to allow the gases produced in the cell to naturally dissipate in the pool Attach the cell to the union and then use the fittings supplied to attach the lower end of the cell to either the hose or rigid PVC pipe coming from the pools filtration system Tighten all union nuts BY HAND ...

Page 17: ...al above ground pool systems To provide safe operation the Aqua Trol Above Ground Pool Automation must be properly grounded and bonded Input Power Models with the standard 120 VAC line cord should be plugged into a GFCI receptacle Twist lock models should be plugged into a twist lock receptacle wired to a GFCI circuit breaker For Canadian installations Connect to a circuit protected by a Class A g...

Page 18: ...omation s filter pump output is rated at 120 VAC 15A max Check the electrical rating marked on the pump motor Connecting a pump with a higher amperage rating may result in permanent damage to the Aqua Trol Above Ground Pool Automation The 120 VAC standard or twist lock pump receptacle is located outside on the bottom of the enclosure ElecTrol ytic Cell The cell plugs into connectors on the Aqua Tr...

Page 19: ...button the display will revert back to the default salt display Also if the button is not pushed for 30 seconds the display will revert back to the standard salt display Common Problems and Solutions 1 Power LED not on Check to make sure 120VAC input power is connected to the Aqua Trol Above Ground Pool Automation control Verify input voltage with a voltmeter If there is input power the circuit br...

Page 20: ...nds to stop the Inspect Cell LED flashing 9 Inspect Cell LED illuminated Remove and inspect the cell for scale If the cell is scaled follow the directions on page 8 for cell cleaning If the pool has the proper amount of salt and the Inspect Cell LED is still illuminated the cell may be worn and need replacement 10 Possible causes of little or no free chlorine residual Aqua Trol Above Ground Pool A...

Page 21: ...replace the defective product and return it freight prepaid If the defective product is returned freight prepaid to Goldline more than three 3 years but within five 5 years of the date of the initial system installation Goldline at its option will either repair or replace the defective product and will charge sixty percent 60 of the current list price for such repairs or replacements plus shipping...

Page 22: ...ce unauthorized repairs or alterations fire flood lightning freezing external water war or acts of God THE EXPRESS LIMITED WARRANTY ABOVE CONSTITUTES THE ENTIRE WARRANTY OF GOLDLINE CONTROLS INC WITH RESPECT TO ITS POOL AUTOMATION AND CHLORINATION PRODUCTS AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN NO E...

Page 23: ...2019 2628 2019 10 10 Questions Visit your local Authorized Aqua Trol Above Ground Pool Automation Dealer or call 1 888 238 7665 POOL for assistance ...

Page 24: ...2019 2628 2019 10 10 ...

Reviews: