OPERATION

The wireless remote display/keypad communicates with the base receiver on the
Aqua Logic control unit using RF (radio frequency) technology.  All of the display
information is transmitted from the Aqua Logic control unit to the wireless remote
display/keypad and all the button press information is transmitted by the Remote RF
unit back to the Aqua Logic control unit.

If the display information is not being updated on a regular basis or if the Aqua Logic
is not responding to buttons being pressed, then refer to the Troubleshooting sec-
tion for assistance in resolving these problems.

When power is turned on, all the LED indicators will flash briefly, the display back-
light will illuminate, and the following display will appear for a short period of time:

The "r1.00" is the software revision level.  The actual revision level for your wireless
remote display/keypad may be different.  Refer to the Aqua Logic Operation Manual
for complete operating instructions.

TROUBLESHOOTING

1.

Can’t find the “Teach Wireless” display:

  Press the “menu” button (possibly

more than once) until “Settings Menu” is displayed.  Next, press the “<“ or “>”
buttons (possibly more than once) unit the “Teach Wireless” display appears.  If
you get to the point where “Settings Menu” appears again, then this means that
the Aqua Logic control unit is not communicating with the base receiver.  Check
that the 4 wire cable from the base receiver is plugged into the “wireless" connec-
tor on the main printed circuit board.  If this connector is already plugged in (for
more than 30 seconds), then call Goldline Technical Service for assistance.

2.

“Teach Wireless” failed: 

 Ensure that the remote is powered when pressing the

button.  This is indicated by any message on the display of the remote.  If the
remote is powered, then the next most likely cause is that the distance between
the base receiver and the remote is too great—try moving the remote closer to the
receiver.  Lastly, there may be other equipment in the neighborhood that is using
the same frequency.  To see if this is the case, go to the Settings Menu/Wireless
Channel and select another channel.  Note that after you change the channel you
will have to “re-teach” every wireless remote device in the system.

3.

Unreliable communication with remote devices: 

 The most likely cause is that

the distance between the base receiver and the remote is too great—try moving
the remote closer to the receiver.  Lastly, there may be other equipment in the
neighborhood that is using the same frequency.  To see if this is the case, go to
the Settings Menu/Wireless Channel and select another channel.  Note that after
you change the channel you will have to “re-teach” every wireless remote device
in the system.

4.

Wireless display/keypad not functioning (no display, no LEDs illuminated)

If  the display/keypad located on the main unit is working correctly, check that
the wall mount power supply is plugged into an active 120VAC outlet and its

3

Goldline Aqua Logic

RF Display r1.00

Summary of Contents for AQL-REMOTE-RF-PS-4

Page 1: ...gic Aqua Logic Aqua Logic Aqua Logic Automation and Chlorination model AQL REMOTE RF PS 8 shown above Installation Operation Manual for model AQL REMOTE RF PS 4 AQL REMOTE RF PS 8 AQL REMOTE RF PS 16...

Page 2: ...ireless remote display keypad The wireless remote display keypad is designed to mount onto a standard electrical utility box same size as used for a triple light switch or can be mounted directly onto...

Page 3: ...ypad for 4 seconds At this point the LCD on the wireless remote display keypad will indicate Teach Wireless Success ful and the local display keypad on the Aqua Logic control unit will also confirm Te...

Page 4: ...the base receiver is plugged into the wireless connec tor on the main printed circuit board If this connector is already plugged in for more than 30 seconds then call Goldline Technical Service for as...

Page 5: ...or On for 60 sec After you have selected the desired operation press the Menu button to lock in your setting Note that this selection applies to this display keypad only Repeat the process for each d...

Page 6: ...tial system installation Goldline Controls will at its option either repair or replace the defective product and return it freight prepaid If the defective product is returned freight prepaid to Goldl...

Page 7: ...t If written proof of the date of the initial system installation is not provided to Goldline the manufactur ing datecode on the product or part will be the sole determinant of the date of the initial...

Page 8: ...the In dustry Canada technical specifications were met Interference This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rule...

Reviews: