1.  Manual Operation (control panel) 

 

1)  Close all the doors and windows. 
2)  Plug-in and power on, unlock the product by long pressing the Start touch key < > and 

the Lock touch key < > on the device for 3 seconds until there is a beep. 

3)  Select time setting <15 mins>, <30 mins> or <60 mins> by the Time Setting touch key, 

the touch key indicator light turns on. 

4)  Press the Start touch key, audible alarm starts beeping regularly for 30 seconds. The 

UV lamp will turn on after the 30 seconds delay when disinfection time is set. 

5)  Once  the  disinfection  process  ends,  the  touch  key  indicator  light  turns  off  and  an 

audible alarm sounds. Open the doors and windows to ventilate the disinfected area. 

 

 

Warning: 

Don’t look at the disinfection light directly.   

People, pets  and  plants  should  leave  the 

area when using the disinfection light. 

Ventilate for 30-40 minutes after working. 

 

2.  Remote Control Operation 

 

1)  Close all the doors and windows. 
2)  Plug-in and power on, unlock the product by long pressing the Start button < > on the 

remote control and the Lock touch key < > on the device for 3 seconds until there is a 
beep. 

3)  Select time setting <15 mins>, <30 mins> or <60 mins> by the Time Setting button on 

the remote control, the touch key indicator light on the device turns on. 

4)  Press the Start button, audible alarm starts beeping regularly for 2 minutes. The UV 

lamp will turn on after the 2 minutes delay when disinfection time is set. 

5)  Once the disinfection process ends, the touch key indicator light on the device turns off 

and an audible alarm sounds. Open the doors and windows to ventilate the disinfected 
area. 

 

Note: if the remote control loses pairing with the device, re-do the pairing by pressing the 
Start button on the remote control and switch on (plug-in) the device for 5 seconds. One 
remote control can be matched with multiple units of the same model. 

 

Summary of Contents for UVP36

Page 1: ...ght source Eye or skin irritation may result from exposure Use appropriate shielding IR may be emitted from the light source Do not look at operating lamp CAUTION To avoid eyes and skin exposure to UV...

Page 2: ...rt touch key Lock touch key 15 mins touch key 30 mins touch key 60 mins touch key Cap UV Tube Lamp Tube Safety Catch Power Cable 2 Preparation and Notes Keep in mind of the following information Delay...

Page 3: ...ock the product by long pressing the Start and the Lock touch keys for 3 seconds until there is a beep On either the fixture control panel or supplied remote control Press the 15 mins 30 mins or 60 mi...

Page 4: ...Guangzhou Haoyang Electronic Co Ltd E mail support goldenseauv com Tel 86 20 3996 6388 Addr No 109 Haiyong Road Shiji Town Panyu Zone Guangzhou China 511450...

Page 5: ...UVP36 USER MANUAL KEEP THIS MANUAL FOR FUTURE NEEDS...

Page 6: ...manual carefully before installing and operating the device Contents 1 Manual Operation control panel 3 2 Remote Control Operation 3 3 Motion Sensor Operation if the lamp with Motion Sensor 4 4 Fall...

Page 7: ...overexposure the operator must wear protective clothing and UV glasses when operating and make sure the disinfection area is safeguarded during the entire disinfection process b Maintenance and servi...

Page 8: ...light Ventilate for 30 40 minutes after working 2 Remote Control Operation 1 Close all the doors and windows 2 Plug in and power on unlock the product by long pressing the Start button on the remote...

Page 9: ...e or something moving around within its detecting range even outside the rooms and it will turn on again when someone or something is left detecting range 3m in an open area without any of the above i...

Page 10: ...way of disinfecting rooms against germs and viruses According to the guideline indoor spaces should be disinfected with UV light with an intensity of over 1 5 watts per square meter An UV lamp can di...

Page 11: ...EIGNEZ TOUJOURS LA LAMPE AVANT L ENTRETIEN UV C RISK GROUP 3 WARNING UV C emitted from this product Avoid eye and skin exposure to unshielded product Follow installation instructions and user manual G...

Page 12: ...auv com 7 8 Product Overview 9 Dimensional Drawings 1 Buzzer 2 Start touch key 3 Lock touch key 4 15 mins touch key 5 30 mins touch key 6 60 mins touch key 7 Cap 8 UV Tube 9 Lamp Tube Safety Catch 10...

Page 13: ...push the UV tube downwards until it fits into place correctly and tightly Note direct contact with new UV tube should be avoided as grease from your skin may reduce the efficiency of the UV tube It i...

Page 14: ...rt Beeping for 30 seconds regularly frequency increase in the countdown 10 seconds Lamp Strike UV Lamp on after 15 seconds when the beeping stops Emitting working Single beep Motion Detected Dual beep...

Page 15: ...uired 2 For cleaning of the device please use a lint free cloth 3 To avoid damage to the device never use detergent or solvents 4 Never spray insecticide towards the device it can discolor or damaged...

Page 16: ......

Reviews: