GM Electronics Ltd.
Golden Mask Deep Hunter pro2 – Instruction Manual
5
sensitivity of the device in all areas. The process is known as "Ground Balance"
and have to be done mandatory before beginning of work, no matter what the
environment in which we are looking for metal objects.
This process includes the following activities:
1.
Search antenna must be placed on the ground in an area where it is assumed
that no buried metal objects.
2.
The potentiometer
"CRACKLE On/Off"
should be set to
"5"
.
3.
Set the value of the desired sensitivity of the device (depth of detection) with
potentiometer
"SENSITIVITY"
(larger values provide high sensitivity).
The values that are selected depend on the nature of the environment in which
will be done searching - in "light" soil can be initiated with values around
"7"
÷ "9"
; in "heavier" soil it is better to choose the value
"5"
or less in the scale of
the potentiometer. Subsequently, this value can be increased to the maximum
possible for the conditions.
4.
Turn potentiometer
"GROUND"
in the direction counterclockwise to stop.
Then turn it in the direction clockwise to do 5 turns. Such way it will be set it in
its middle position.
5.
Turn the
"VOLLUME On/Off"
in a clockwise direction to be switched
“On”
the detector and set the level of the volume. Values around
"6" ÷ "8"
on
the scale of the potentiometer are usually sufficient for the job.
6.
Turn
"GROUND"
in the direction counterclockwise to the emergence of
sound - "hum" or "pop" (setup known as "threshold").
Achieving such a setup is very important for a successful operation and
maximize the potential of the detector.