GM Electronics Ltd

.

"Battery Check"  

- button to check the level of battery charge.

This button can be used at any time when the detector is switched
“ON”. When the arrow is in the red sector, the battery should be
recharged! 

4.Ground Balance. 

The

  Golden   Mask   Deep   Hunter   Pro5  

provides   full   range

automatic ground balance based on a proprietary  

“Flash Auto

Ground Balance” 

system that is unique to this detector. It does

not   need   any   settings   and   continuously   rejects   the   signals
generated   by   changing   soil   conditions   encountered   while
searching. 
In  extremely  high mineralized soils the noises can be reduced
additionally   by   the  

“TRASH”  

control   knob   or   by   reducing   the

“SENSITIVITY”  

of   the   detector   (decrease   the   value)   and/or

switch 

“Off”

 the 

“BOOST”

 function. 

5.Search for metal objects with frame search coil

The Golden Mask Deep Hunter Pro5  

is designed to be used

with large “frame” type search coils. This is the most effective way
to search for deeply buried metal objects. 
The search coil is moved slowly at a 

constant height

 

(15 cm or

more)

 above the ground. Coils of type “frame” are delivered in the

form of “coil-cable loop” in length corresponding to the respective
size of the supporting frame and a set of PVC pipes and fittings
for assembling the supporting structure of the frame. The “coil-
cable   loop”   is   composed   of   series-connected   conductors   in   a
multi-conductor special cable which form a send-receive coil. The
“coil-cable loop” is mounted onto a frame of PVC pipes, unions
and elbows attached to the PVC frame using the included “Velcro”
cable straps. The connecting cable is plugged into the connector
labeled  

“Coil”

, which is mounted on the right edge of the front

                             Golden Mask Deep Hunter Pro5 – Instruction manual

          

6

Summary of Contents for Deep Hunter Pro 5

Page 1: ......

Page 2: ...lectrical interference This detector offers remarkable stability sensitivity and accuracy that is achieved with the use of very simple and intuitive settings Pulse induction is based on the processing of short and intensive magnetic pulses which are emitted by means of a search coil Those magnetic pulses produce electrical eddy currents in conducting metallic objects Eddy currents will be stored i...

Page 3: ...desired by the customer The use of self made or other brands of coils will damage the Electronics Unit and will void the warranty The main search coils of the Golden Mask Deep Hunter Pro5 is a square frame made from PVC pipes unions and elbows that form the coil support frame The antenna is a special cable like loop that is attached to the support frame with Velcro straps Searching with this type ...

Page 4: ...UME ON Off knob to switch ON Off the detector and adjusting the level of sound SENSITIVITY knob to adjust the sensitivity of the detector AUDIO TONE On Off knob for adjusting the ticking frequency in absence of metal within the area of the search antenna In position On the detector is in its core search mode This is strictly individual adjustment and relates exclusively to the individual auditory ...

Page 5: ...ue rejects more objects The RETUNE button is for quick readjustment and stabilization of the detector by removing interferences encountered during the search process BOOST is for amplification of the received signal in position ON it gives about 20 extra depth of detection without use of additional battery power After turning the switch BOOST to ON position RETUNE must be pressed SIGNAL is a preci...

Page 6: ...for metal objects with frame search coil The Golden Mask Deep Hunter Pro5 is designed to be used with large frame type search coils This is the most effective way to search for deeply buried metal objects The search coil is moved slowly at a constant height 15 cm or more above the ground Coils of type frame are delivered in the form of coil cable loop in length corresponding to the respective size...

Page 7: ... or injuries If you do not have an assistant dragging of the search coil on a non metallic sled PVC for example is recommended The sled must provide a constant height about 15 cm or more of the frame from the ground surface The search should always begin with a brief pressing of the RETUNE button the same is recommended to be carried out periodically during the search in order to maintain maximum ...

Page 8: ... apply as well to searches with hand the round coils 7 Indication of the presence of a metal object within the coil area The signal from a metal object located in the area of the search coil is indicated by increasing the frequency of the sound signal ticking sound Most weak signals an operator is able to notice are improved by doubling the preset frequency of the sound with the AUDIO TONE On Off ...

Page 9: ...E button and then pass the antenna over the target from a different direction Repeat as many times as you want to identify the type of the metal more securely With a little experience anyone can learn to recognize the nature of the various signals which will lead to better use of the great capabilities of the Golden Mask Deep Hunter Pro5 8 Signal additional amplification BOOST The additional ampli...

Page 10: ...ent mode sometimes could return acceptable results but the Golden Mask Deep Hunter Pro3 provides the ability to eliminate small metal objects without reducing the sensitivity This is accomplished with the TRASH knob The lower the value selected with this knob smaller metal objects are detected After doing some tests with multiple samples of different metallic objects and sizes you will learn which...

Page 11: ...ompleted remove the charger from the power socket and then remove the charger jack from the connector Charge 3 Turn On the detector and check the charge level by pressing Battery Check button With a properly charged battery the arm of the indicator must show a value greater than 8 If the reading is lower than 8 reconnect the charger and repeat the charging process To replace the battery you should...

Page 12: ...r during operation do this 1 Set TRASH 0 BOOST ON CRACKLE 5 SENSITIVITY 10 VOLUME 8 2 Place the coil on the ground surface 3 Switch ON the detector 4 Pres and hold the RETUNE button and turn the SENSITIVITY knob counterclockwise to find the max value which can be used 5 Release the button RETUNE 6 Lift the coil to working distance above the ground surface 7 Reduce rotate in counterclockwise very f...

Page 13: ...s it is not sealed When you connect the coil to the electronics you should prevent the entry of dirt or moisture in and around the contact pins of the connectors 6 Working with the detector in industrial areas and places with a large amount of metal junk in the soil and or with presence of industrial electromagnetic interferences can lead to instability and or inability to work This requires reduc...

Page 14: ...in battery is discharged as this can result in damage to the battery and or the electronics 11 Always keep the electronics clean from dust grease and moisture Use only dry and soft cotton cloth for cleaning 12 If you use the detector in areas where there is possibility of the presence of buried weapons and or explosives you must proceed with great caution The manufacturer and the dealers are not r...

Page 15: ... For frame coils coins nails and other very small metal objects will cause two signals when passing over them while large metal objects will produce and extensive signal of long duration For all coils frame and round deeply buried metal objects will cause a weak and slowly increasing sound and meter reading and reach their peaks at the target center Targets near the surface generate a strong and r...

Page 16: ...cs Ltd Shallow target large deep target large deeply buried targets will cause a long duration signal increasing in intensity and pitch as the center is approached Golden Mask Deep Hunter Pro5 Instruction manual 16 ...

Reviews: