Golden Designs DYN-HTR-1500-200 User Manual Download Page 1

 

 

Dynamic Infrared Heater 

User’s Manual 

Model# DYN-HTR-1500-200

 

 

 

 

FOR INDOOR USE ONLY 

120VAC 15 AMP DEDICATED CIRCUIT 
 

The Dynamic Infrared Heater works with your in-home furnace to provide 

supplement heat.  Carefully and thoroughly read this manual before using the 

Dynamic Infrared Heater for the first time.  We recommend keeping this manual for 

regular review and future reference.  Heater is intended for residential use. 

 

Summary of Contents for DYN-HTR-1500-200

Page 1: ...IRCUIT The Dynamic Infrared Heater works with your in home furnace to provide supplement heat Carefully and thoroughly read this manual before using the Dynamic Infrared Heater for the first time We r...

Page 2: ...always be followed to reduce the risk of fire electric shock and injury to persons Please adhere to the following safety instructions The heater must be operated by an adult Keep heater out of the re...

Page 3: ...0 9 in Thermostat Electronic Analog Heater Size 14 9 in x 13 in x 17 7 in Fan System Cross Flow Fan Net Weight 25 lbs Fan Noise Level 46 db Gross Weight 28 lbs BTU Approximately 5100 Cabinet Wood Dark...

Page 4: ...ow Fan will continue to circulate the airflow after the power is turned off to circulate the warm air from the Dynamic Infrared Heater cooling the unit down D The LED Digital Display is a convenient s...

Page 5: ...lug the power cord directly into a conventional 120V 15 amp outlet and press the MASTER POWER switch on the rear of the portable heater Then press the POWER button on the front control panel or on the...

Page 6: ...e status will switch back to the temperature status 4 Again the default set temperature displayed on the LED display is 720 F By pressing the TEMP button the LED display will switch to the temperature...

Page 7: ...set desired temperature reading is defaulted to 72 degrees Fahrenheit You see this displayed when you first turn on the heater The set desired temperature reading has nothing to do with calibrating t...

Page 8: ...e closed This allows the heater to function in an isolated area 5 It is not recommended to operate heater in areas exposed to non insulated concrete or metal walls Concrete floors should be covered to...

Page 9: ...front grill and rear air intake to make sure it is not being blocked by any kind of debris 3 PROBLEM a The portable heater will not turn on SOLUTION First test your outlet to make sure it has power Y...

Page 10: ...gnal Cable or other relevant plugs may have become disconnected Please contact the manufacture for further troubleshooting 7 PROBLEM a The heat emitter is functioning and the air outflow is working bu...

Page 11: ...transportation of the parts In addition you are responsible for insuring any parts shipped or returned You must present Dynamic with proof of purchase documents including the date of purchase Any evi...

Page 12: ...12 Page Is Intentionally Left Blank...

Page 13: ...mailed back within 60 days of purchase date along with proof of purchase Serial number S N is located on the heater s front panel rear panel or on the carton DETACH HERE AND MAIL BOTTOM PORTION WITH...

Reviews: