background image

SUPPLEMENTAL INSTRUCTIONS FOR GB “3 IN 1” SAFETY PILOT KITS

Make sure you have the correct GB Kit for Natural or L.P. Gas.

The Safety Pilot Kit attaches to the burner pan as shown above.
Use soapy water when checking all fittings for leaks.

LIGHTING INSTRUCTIONS

To light, turn control knob clockwise to pilot position and then hold match to end of thermocouple assembly while 
pushing in control knob.
Hold knob in about 2 minutes and slowly release knob. If the flame goes out turn knob counterclockwise to off  
position and repeat procedure after waiting 5 minutes.
FIREPLACE DAMPER MUST BE IN FULL OPEN POSITION BEFORE LIGHTING MAIN BURNER.
After the pilot flame is burning, turn control knob to “ON” position. If the main burner does not light within 4  
seconds, turn knob counterclockwise to “OFF” position. Wait 5 minutes and repeat procedure from step one.

LIMITED WARRANTY

Golden Blount Gas Logs are warranted against defective materials and/or workmanship for 
as long as you own them. Burner pan assemblies are guaranteed for five years from date 
of purchase. Safety Pilot Assemblies are covered for one year.

This warranty does not cover parts subjected to misuse, abuse, improper handling or improper 
installation. The GB warranty specifically excludes any liability for indirect, incidental or 
consequential damage to property.

Defective logs or defective parts should be returned to your dealer or to the factory prepaid 
with a copy of your sales receipt. Defective parts will be repaired or replaced at the factory’s 
option and returned to you prepaid.

GOLDEN BLOUNT - 4301 WESTGROVE DRIVE - ADDISON, TX 75001

 PILOT FLAME 

ADJUSTMENT

CONTROL KNOB

HEAT SHIELD

 ADJUST PILOT 

FLAME TO COVER 

THERMOCOUPLER

ALL GOLDEN BLOUNT GAS LOG PRODUCTS USING THE 3 IN 1 GAS CONTROL VALVE CAN BE EASILY CONVERTED TO AN 
OFF/ON SOLENOID OR AN ADJUSTABLE MOTOR FLAME HEIGHT. ASK YOUR DEALER OR CALL 1-800-833-1139.

Summary of Contents for Radco

Page 1: ...guish any open flame 4 Immediately call your gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance Listing 1269 The installation including provisions for combustion and ven tilation air must conform with local codes or in the absence of local codes with the national fuel Gas Code ANSI Z223 1 1988 and NFPA54 1...

Page 2: ... 30 and 36 sets are packed in 3 boxes 2 for logs and 1 for component parts Components Parts For Natural Gas ITEM 1 Damper Clamp 2 Log Grate 3 Gas Pan Burner 4 Cast Iron Burner Cap 5 Orifice 6 Aluminum Connector 7 Silica Sand Vermiculite supplied with L P sets 8 Black Volcanic cinders 9 Glowing Embers w hardware kit 10 Ceramic Logs Number of logs per set varies with set size Maintenance Removal of ...

Page 3: ...rs over brass air mixer attached to burner pan Air mixer holes must not be obstructed 7 Evenly spread glowing ember material over the burner pan and replace grate 8 Place logs on grate A The longest log is the bottom front log B Next longest log is the bottom back log to be positioned 3 behind the front log C The positioning of the top logs is a matter of the installer s choice Note Illustration s...

Page 4: ...step one LIMITED WARRANTY Golden Blount Gas Logs are warranted against defective materials and or workmanship for as long as you own them Burner pan assemblies are guaranteed for five years from date of purchase Safety Pilot Assemblies are covered for one year This warranty does not cover parts subjected to misuse abuse improper handling or improper installation The GB warranty specifically exclud...

Reviews: