background image

Thank you for purchasing this Goldair product. Your product is warranted against faults and manufacture when used in normal
domestic use for a period of

one year.

In non-domestic use Goldair limits the voluntary warranty to

three months.

Goldair undertake to repair or replace this product at no charge if found to be defective due to a manufacturing fault during the
warranty period.

This warranty excludes damage caused by misuse, neglect, shipping accident, incorrect installation, or work carried out by anyone
other than a qualified electrical service technician.

PLEASE KEEP YOUR RECEIPT AS THIS WILL HELP VERIFY YOUR WARRANTY.

The benefits to you given by this warranty are in addition to other rights and remedies available to you under a law in relation to
the goods or services to which this warranty relates.

In Australia, our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a
replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also
entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a
major failure.

In New Zealand this warranty is additional to the conditions and guarantees of the Consumers Guarantee Act (1993).

One Year Warranty

Goldair One Year Warranty 

(IMPORTANT: Please complete and retain this warranty card)

Name

Address

Place Of Purchase

Date of Purchase

Name Of Product 

Model Number

Attach a copy of the purchase receipt  to this warranty card

Due to continual design improvements, the product illustrated in this User Manual may differ slightly from the actual product.

Goldair 

New Zealand

CDB Goldair
PO Box 100-707
N.S.M.C
Auckland

Phone +64 (0)9 917 4000
Phone 0800 232 633

www.goldair.co.nz

Goldair 

Australia

CDB Goldair Australia Pty

PO Box 574

South Morang

Victoria, 3752

Phone +61 (0)3 9365 5100

Phone 1300 GOLDAIR  (1300 465 324)

www.goldair.com.au

Summary of Contents for GCPAC07

Page 1: ...Operating Instructions Model GCPAC07 7K BTU 2 0kW Portable Air Conditioner ...

Page 2: ...n use 11 When the appliance has been unpacked check it for transport damage and ensure all parts have been delivered If parts are missing or the appliance has been damaged contact the Goldair Customer Services Team 12 If your appliance does not work or is not working properly contact the place of purchase Repair work on the appliance by unqualified persons can cause serious risk to the user 13 Ens...

Page 3: ...maged in any manner Have the appliance checked and repaired by a qualified electrician if repair is necessary 33 Never place the unit in wardrobes or other enclosed spaces as this may cause fire hazards Any repairs required contact the nearest authorised Service Centre and strictly follow the manufacturer s instruction only Appliance is filled with flammable gas R290 Before using the appliance rea...

Page 4: ...Components ...

Page 5: ...ing plate assembly Half open the window and mount the window sealing plate assembly to the window as shown in Figure 2 and Figure 3 the assembly can be placed in horizontal and vertical direction Pull various components of the window sealing plate assembly open adjust their opening distance to bring both ends of the assembly into contact with the window frame and fix various components of the asse...

Page 6: ...on for the first time it will beep and then the unit will be in standby 1 Power Button Press the button to turn the unit ON and OFF 2 Mode Button Press the button to switch between Cooling Dehumidification Fan modes 3 Sleep Button In the Cooling Mode Press the UP and Fan buttons together to turn on the sleep mode The unit will work in Energy Saving and quiet mode Note You cannot not use sleep mode...

Page 7: ...rn the unit ON or OFF from 1 24 hours To set the timer to turn the unit OFF press the TIMER button while the unit is operating and set the desired number of hours before the unit turns off To set the timer to turn the unit ON press the TIMER button while the unit is in standby and set the desired number of hours before the unit turns on Control Panel and Remote Control 3 5 2 4 7 Remote Control The...

Page 8: ...on the back of the unit Unscrew the drainage cover and unplug the water plug the water will automatically flow into the water container During drainage the body can be tilted slightly backwards When the water is discharged replace the water plug and re tighten the drainage cover Allow unit to sit for at least 5 minutes before turning back on Do not use this Air Conditioner with a programmer remote...

Page 9: ...evice with water DO NOT immerse the unit in water and never allow water to enter the motor housing DO NOT use harsh chemicals to clean the unit Do not attempt to dismantle the Air Conditioner There are no user serviceable parts For service or repair contact an authorised electrical service technician STORAGE To store the unit remove the plug from the socket Remove the rubber plug from the drainage...

Page 10: ...r heating effect is not good There is direct sunlight Pull the Curtain Doors or windows are open there are a lot of people or in cooling mode there are other sources of heat Close doors and windows The filter screen is dirty Clean or replace the filter screen The air inlet or outlet is blocked Clear obstructions Loud Noise The air conditioner is not placed on a flat surface Put the air conditioner...

Page 11: ... under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure In New Zealand this warranty is additional to the conditions and guarantee...

Page 12: ...New Zealand PO Box 100707 North Shore Mail Centre Auckland 0745 www goldair co nz Australia PO Box 574 South Morang Victoria 3752 www goldair com au ...

Reviews: