background image

Thank you for purchasing this Goldair product. Your product is warranted against faults and manufacture when used in
normal domestic use for a period of

one year.

In non-domestic use Goldair limits the voluntary warranty to

three

months.

Goldair undertake to repair or replace this product at no charge if found to be defective due to a manufacturing fault
during the warranty period.

This warranty excludes damage caused by misuse, neglect, shipping accident, incorrect installation, or work carried out
by anyone other than a qualified electrical service technician.

PLEASE KEEP YOUR RECEIPT AS THIS WILL HELP VERIFY YOUR WARRANTY.

The benefits to you given by this warranty are in addition to other rights and remedies available to you under a law in
relation to the goods or services to which this warranty relates.

In Australia, our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are
entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or
damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.

In New Zealand this warranty is additional to the conditions and guarantees of the Consumers Guarantee Act (1993).

One Year Warranty

Goldair One Year Warranty 

(IMPORTANT: Please complete and retain this warranty card)

Name

Address

Place Of Purchase

Date of Purchase

Name Of Product 

Model Number

Attach a copy of the purchase receipt  to this warranty card

Due to continual design improvements, the product illustrated in this User Manual may differ slightly from the actual product.

Goldair – New Zealand

CDB Goldair
PO Box 100-707
N.S.M.C
Auckland

Phone +64 (0)9 917 4000
Phone 0800 232 633

www.goldair.co.nz

Goldair – Australia

CDB Goldair Australia Pty

PO Box 574

South Morang

Victoria, 3752

Phone +61 (0)3 9336 4423

Phone 1300 GOLDAIR  (1300 465 324)

www.goldair.com.au

Summary of Contents for GCMF100

Page 1: ...Operating Instructions 40cm Misting Fan Model GCMF100 ...

Page 2: ...ildren with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they are supervised or have been given instruction concerning the use of the Fan by a person responsible for their safety 16 Never place appliance close to radiant heat source 17 Never operate in areas where petrol paint or other flammable liquids are used or stored 18 Never use the appliance to ...

Page 3: ... heat HOW IT WORKS This Mist Fan uses ultrasonic vibration to atomise water into 1 5 micron particles which can then be blown through the room with the fan WHY IT IS USEFUL Not only does this fan help to cool you down with air containing micro water droplets it also helps to avoid dry skin and eyes which are common in dry heat A relative humidity of 45 65 is recommended for comfortable living and ...

Page 4: ...l packaging has been removed from the unit before use This appliance requires no installation it should be used solely as a portable appliance Assemble the fan body to the Stand Tubes using the 2x screws provided Attach the Humidifier base to the Fan base using the screw provided To assemble the safety grill and blade remove the Spinner by turning it clockwise Place the rear safety grill into posi...

Page 5: ...nd nut at the bottom of the grill must be fitted PLACEMENT OF THE WATER TANK PLACEMENT OF THE MIST PIPE Place the Mist Pipe through the middle of the Stand Tubes then pull it up through the hole at the bottom of the Control Panel Guide the Mist Pipe forward through the middle hole in the Control Panel Fig 9 The two free ends of Mist Pipe should now be the same as each other length is 335mm After a...

Page 6: ...oing anything with the water tank When the water level is too low the safety switch will activate and stop operation of the mist function Unplug the unit and refill the water tank for further operation Do not let dust or other particles collect on the mist plate if the mist outlets are blocked the mist function could malfunction Before cleaning the unit make sure it is completely disconnected from...

Page 7: ...Control Panel CONTROL PANEL REMOTE CONTROL ...

Page 8: ...iod of time The Timer LEDs on the control panel 0 5H 1H 2H 4H will light up adding to the current timer setting For example to set the fan to turn off after 3 5hours the first three Timer LEDs should be illuminated MODE SELECT When first switched on the MODE LED will illuminate red indicating that the unit will operate in normal mode Press the MODE button to select desired Mode The Mode is affecte...

Page 9: ...m cleaner to remove dust and fluff from around the grills Never use solutions such as benzene thinners or polishing agents Ensure the Fan is dry before plugging back into the mains supply Never spray with liquids or submerge the Misting Fan in water or any other liquid Do not attempt to dismantle the Fan motor There are no user serviceable parts For service or repair contact an authorised electric...

Page 10: ... Peculiar smell from the mist A When new there might be residue in the water tank mist plate B The water in the water tank may be contaminated A The smell should disappear after further use B Clean out the water tank and refill with fresh water 5 The fan doesn t work as normal A The plug and supply cord are damaged B The blades are bent C Incorrect installation A Find service agent or a suitable q...

Page 11: ... under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure In New Zealand this warranty is additional to the conditions and guarantee...

Reviews: