background image

1.  Ensure  that  the  cap  on  the  Water 
drainage  outlet  of  the  unit  is  tight.  Pour 

clean  cold  water  into  the  water  filler  area, 

observing  the  water  level  indicator  in  the 
bottom front panel. 
  
CAUTION:  DO  NOT  SPILL  OR  ALLOW 
WATER TO COME IN CONTACT WITH  
THE  CONTROL PANEL 
  
Do not overfill past the MAX  water indicator 
mark.  If  desired, place ice  in  the  ice tank  in 
the top of the unit. 
Do not pour water into the ice tank. 
Do not allow the combined use of water and 
ice to overfill the water reservoir. 
When  moving  the  unit,  do  so  with  extreme 
caution,  so  as  not  to  spill  any  water  in  the 
reservoir.  The  unit  should  be  moved  slowly 
and in a sideways direction.  
Always keep the unit upright. 
  
2.  Connect the unit to a power outlet of the 
same voltage and frequency as indicated on 
the  rating  plate.  The  unit  ON/OFF  LED  for 
the  power  will  light  to  indicate  that  there  is 
power to the unit. 
  
3.  Turn  the  unit  ON  by  depressing  the 
ON/OFF  button.  The  unit  will start and then 
revert  to  the  initial  Normal/LOW  speed 
setting. Further operation can be performed 
by  pressing  the  SPEED,  MODE,  TIMER, 
COOL and SWING buttons. 
  
4.  If  you  wish  to  turn  the  unit  off  at  a  pre-
determined time depress the TIMER button. 
The  unit  can  be  set  to  turn  off  at  any  time 
between  0.5  hour  and  7.5  hours  from 

“Turn 

On”  by  depressing  the  TIMER  button.  If  no 
time  is  selected,  the  unit  will  operate 
continuously.  
The  time  set  can  be  incremented  in  0.5hr 
steps and the selected time is indicated by a 
combination of indicator lights. 
Eg.  5.5hrs  is  indicated  by  the  4hr  LED,  the 
1hr  LED  and  the  0.5hr  LED  being 
illuminated. 

  5.  To  initiate  the  cooling  function  depress 
the  COOL  button.  It  will  take a  few  minutes 

for the air to cool. 

  
NOTE:  If  this  button  is  not  depressed  the 
unit  will  only  circulate 

“room  temperature” 

air. 
  
6.  Move  the  horizontal  louver  for  the  air 
outlet to blow up or down to suit. 
 
7.  The  vertical  louvres  can  be  set  to  a 
direction  or  allowed  to  rotate  through  120

o

 

by depressing the SWING button. 
 
8.  All  the  functions  can  be  performed  with 
the remote control supplied with this unit. 
a)  Point  the  remote  towards  the  unit  and 
depress the appropriate button. The remote 
control  will  operate  up to  4 metres  from  the 
unit. 
b)  Remove  battery  cover  and  install  two 
“AAA”  batteries  (not  included)  as  indicated. 
(Please observe correct battery polarity.) 
  
9.    Depress  the  OFF  button  to  cancel  all 
functions. 
 
10.    When  not  in  use  disconnect  the  unit 
from  the  power  outlet  and  drain  all  water 
from  the  water  reservoir.  (See    HOW  TO 
CLEAN) 
  
NOTE:  Initial  setting  is 

“normal”  mode  and 

“low”  speed  and  will  occur  every  time  the 
plug into plugged into the power main. Once 
the cooler has been set to desire function/s, 
the  cooler  will  keep  memory  of  the  setting 
as long as there is power to the cooler (step 
2)  when  it  is  switched  OFF,  and  without 
unplugging the plug from the power main. 

 

Operating your Fan 

Summary of Contents for GCEV100

Page 1: ...a 3V CR2032 battery Operating Instructions Item GCEV100 10L Evaporative Cooler with Timer ...

Page 2: ...ildren with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they are supervised or have been given instruction concerning the use of the Fan by a person responsible for their safety 16 Never place appliance close to radiant heat source 17 Never operate in areas where petrol paint or other flammable liquids are used or stored 18 Never use the appliance to ...

Page 3: ...ts 1 Control panel 7 Water filling box for water and ice 2 Louvre 8 Back cover 3 Water level indicator 9 Air filter 4 Wheel 4pcs 10 Water drainage outlet 5 Water tank 11 Handle 6 Power Cord Control Panel Layout ...

Page 4: ...igh Mid Low the relevant SPEED indicator LED will light up The SPEED function High Mid Low can also be used in conjunction with the SLEEP and Natural MODE function TIMER Press to set the length of time before the cooler switches itself OFF Press once for every 0 5hr increments Maximum allowable time is 7 5hrs For example if 0 5hr and 1 0hr lights on at the same time it means the timer is set 1 5hr...

Page 5: ... is selected the unit will operate continuously The time set can be incremented in 0 5hr steps and the selected time is indicated by a combination of indicator lights Eg 5 5hrs is indicated by the 4hr LED the 1hr LED and the 0 5hr LED being illuminated 5 To initiate the cooling function depress the COOL button It will take a few minutes for the air to cool NOTE If this button is not depressed the ...

Page 6: ...ter or empty the unit outside You may have to empty the water collector a few times finally recap the plug of the water drainage outlet 3 It is recommended that the filter be cleaned once every week The air filter is connected into the back cover via two clips at the top Release by pressing the two clip down and give it a little push Care full not to damage the filter CAUTION Do not immerse or all...

Page 7: ... under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure In New Zealand this warranty is additional to the conditions and guarantee...