Warnings
1.
Do not disassemble any part of the product.
2.
Do not use any part of the product for other purposes.
3.
For service and problems of any kind, contact qualified Gold Note personnel.
4.
Protect the product from rain and humidity and keep away from heat sources, electric and electronic
motors etc.
5.
The power Chord supplied must be used only on this unit.
6.
Gold Note does not have responsibility for any improper use of this unit
Warranty Certificate – Customer Service – Warnings - F.A.Q.
AP-7
Italian 40 Watt Integrated Amplifier
Troubleshooting
SYNPTOM
DESCRIPTION
CAUSE
REMEDY
SPEAKER
HUMMING
PROBLEMS
The speakers hum
when the amplifier is
connected to the
system
•
The unit is correctly
coupled with the Ground on DC.
•
Be sure your area and
personal environment are well
grounded eventually isolate the
ground Pin of the power chord
plug for verification.
CHASSIS VIBRATION
The unit features an
internal fan to prevent
the protection shut-off
the unit early in warm
environments.
•
•
The fan constantly runs at
low speed and it isolated with soft
silicon. Anyway to stop it run it
can be switched out opening the
unit cover and pulling out the two
fan’s pin connector.
•
The interconnect input
and/or output cables are not
shielded.
•
Be sure to always use
shielded cables for unit
connections.
SWITCHING
ON/OFF
BUMP
The Stage bumps any
time is switched ON or
OFF
•
It is important to notice
that it does not produce any risk
even if the bump is high
•
10