Spartan
Model No.2671
Page 5
gmpopcorn.com
A certified electrician must furnish sufficient power for proper machine operation and install any
supplied receptacle. We recommend this equipment be on a dedicated and protected circuit.
Failure to wire properly will void the warranty and may result in damage to the machine. It is Gold
Medal Products Co.’s recommendation that this machine be plugged directly into a wall outlet. The
use of extension cords is not recommended due to safety concerns, and may cause sacrificed
and/or reduced performance. Make sure cord is located to prevent a trip hazard or unit upset.
Receptacle Wiring Diagram for NEMA 14-50 (for Domestic Units)
A certified electrician must follow the IMPORTANT instructions below for installation of the
NEMA 14-50 Receptacle (Gold Medal Item No. 82920) provided with the unit. If the receptacle is
wired incorrectly, the heat elements/kettle and other electrical components could be at 208 or
240 V potential instead of the needed 120 V, resulting in excessive temperatures in the heat
elements (i.e.: kettle) and possible fire, and/or damage to electrical components.
Receptacle Wiring Diagram (for Export Units)
A certified electrician must supply and install the required wall receptacle for this unit, follow
the IMPORTANT instructions shown. This unit is designed to operate on single phase, 16 AMP, 4
wire supply. All electrical components in this machine are 230 V. If the receptacle is wired
incorrectly, the heat elements/kettle and other electrical components could be at 400 V potential
instead of the needed 230 V, resulting in excessive temperatures in the heat elements (i.e.: kettle)
and possible fire, and/or damage to electrical components.
3P+N+E IEC 309
(Front View)
3P+N+E IEC 309
(Back View)
PE-G
L2
L1
Connect to Black
(Hot) Wire
Connect to Brown
(Hot) Wire
Connect to
Green/Yellow
(Ground) Wire
Connect to Blue
(Neutral) Wire
L3
N
Not Used
(If 5 wires provided,
connect Grey here.)
NEMA 14-50 Receptacle
(Front View)
NEMA 14-50 Receptacle
(Back View)
Connect to Green
(Ground) Wire
Connect to Red
(Hot) Wire
Connect to Black
(Hot) Wire
Connect to White
(Neutral) Wire