Part No. 15 097 5
2
3 / 8
DESIGN
Heating process
Release
Switch-off time
Battery display
Short circuit
Disruption
Test
button
Connection socket
Opening for plug contact
ADVANTAGES AND EQUIPMENT
•
one-button operation
•
microprocessor-operated device
•
LED display
•
display of switch-
off time: ≤ 1.0 s; ≤ 1.1 s; ≤ 1.2 s; ≤ 1.3 s; ≤ 1.5 s and > 1.5 s
with completed dry-wet test of the PTC thermistor of the limit indicator
•
connection socket suitable for all limit indicator connections
•
includes carrying case
•
includes battery charger
START-UP
The product is ready for use.
The function test of the limit indicator should be carried out by a specialised company or an
expert according to water laws.
Application example - Function test of the limit indicator by a specialised company
according to water laws.
Plug the connection socket of the limit
indicator test device type PG 1 on to the plug
of the limit indicator connection
Press and hold the
TEST
button
/LPLWLQGLFDWRUWHVWGHYLFH7\SH)6WRS*:*3*
®