background image

 

 

 

 

 

 

 

 

Part No. 15 097 5

2

3 / 8 

 

DESIGN 

 

 

  Heating process  

  Release 

  Switch-off time 

  Battery display 

  Short circuit 

  Disruption

 

 

Test

 button 

  Connection socket

 

  Opening for plug contact 

ADVANTAGES AND EQUIPMENT 

 one-button operation 

 microprocessor-operated device 

 LED display 

 display of switch-

off time: ≤ 1.0 s; ≤ 1.1 s; ≤ 1.2 s; ≤ 1.3 s; ≤ 1.5 s and > 1.5 s

 

with completed dry-wet test of the PTC thermistor of the limit indicator 

 connection socket suitable for all limit indicator connections 

 includes carrying case 

 includes battery charger 

 

START-UP 

The product is ready for use. 

The function test of the limit indicator should be carried out by a specialised company or an 

expert according to water laws. 

 

Application example - Function test of the limit indicator by a specialised company 

according to water laws. 

 

 

  Plug the connection socket of the limit 

indicator test device type PG 1 on to the plug 

of the limit indicator connection 

  Press and hold the 

TEST

 button 

 

 

 

 

 

/LPLWLQGLFDWRUWHVWGHYLFH7\SH)6WRS*:*3*

®

 

 

Summary of Contents for F-Stop GWG-PG 1

Page 1: ...ALTSVERZEICHNIS ZU DIESER ANLEITUNG 2 NDERUNGEN ZUR VORHERGEHENDEN AUSGABE 2 PRODUKTBEZOGENE SICHERHEITSHINWEISE 2 ALLGEMEINE PRODUKTINFORMATION 2 BESTIMMUNGSGEM SSE VERWENDUNG 2 AUFBAU 3 VORTEILE UND...

Page 2: ...offe bei Wartungsarbeiten auffangen Verwendung in explosionsgef hrdenden Bereichen nicht zul ssig Kann zu Explosion oder schweren Verletzungen f hren Einbau vom Fachbetrieb gem Betriebssicherheitsvero...

Page 3: ...rter Trocken Nasspr fung des Kaltleiter des Grenzwertgebers Kupplungsdose passend f r alle Grenzwertgeber Anschlusseinrichtungen mit Transportkoffer mit Ladeger t INBETRIEBNAHME Das Produkt ist sofort...

Page 4: ...reigabe muss erfolgen 4 Aufheizzeit Erfolgt nach 45 Sekunden keine Freigabe wird die Messung abgebrochen und alle 4 gelben LED leuchten Ursache Grenzwertgeber ist noch eingetaucht Grenzwertgeber ist d...

Page 5: ...elbe LED bei Aufheizen blinkt Abschaltzeit 1 1 Sekunden 1 gr ne LED bei Freigabe blinkt Abschaltzeit 1 0 Sekunden 1 rote LED bei Kurzschluss blinkt Abschaltzeit 1 5 Sekunden Tabelle 1 Temperaturbereic...

Page 6: ...r Wertstoffh fe zu entsorgen TECHNISCHE DATEN Betriebsspannung Ua 19 0 3 V Elektrischer Widerstand Ri 160 3 2 Ladeger t f r Akku Eingang 230 V AC Ausgang 12 V 6 W Kabell nge 1 5 m Schutzart IP64 nach...

Page 7: ...Grenzwertgeber Pr fger t Typ F Stop GWG PG 1 Artikel Nr 15 097 50d 7 8 KONFORMIT TSERKL RUNG F STOP PG 1 EMV ROHS DE 2014 09 15...

Page 8: ...Stop GWG PG 1 Regler und Armaturen Gesellschaft mbH Co KG Obernbreiter Stra e 2 16 97340 Marktbreit Germany Tel 49 9332 404 0 Fax 49 9332 404 43 E Mail info gok online de Internet www gok online de 8...

Page 9: ...AND EQUIPMENT 3 START UP 3 FUNCTION DESCRIPTION 4 OPERATION 5 TROUBLESHOOTING 5 MAINTENANCE 6 REPAIRS 6 DISPOSAL 6 TECHNICAL DATA 6 LIST OF ACCESSORIES 6 WARRANTY 6 TECHNICAL CHANGES 6 DECLARATION OF...

Page 10: ...tallation outside the defined ex zone GENERAL PRODUCT INFORMATION The limit indicator test device type F Stop GWG PG 1 is intended for testing the functions of limit indicators B1 sensors according to...

Page 11: ...t indicator connection socket suitable for all limit indicator connections includes carrying case includes battery charger START UP The product is ready for use The function test of the limit indicato...

Page 12: ...fter 45 seconds the measurement is stopped and all 4 yellow LEDs are lit cause limit indicator is still immersed limit indicator is defective 5 Release the first LED remains lit the tank can be filled...

Page 13: ...conds 1st green LED for release flashes switch off time 1 0 seconds 1st redLED for short circuit flashes switch off time 1 5 seconds Table 1 Temperature ranges and switch off times according to the st...

Page 14: ...lectrical resistance Ri 160 3 2 Battery charger Inlet 230 V AC Outlet 12 V 6 W Length of cable 1 5 m Protection type IP64 acc to EN 60529 Ambient temperature 25 C to 50 C LIST OF ACCESSORIES Product d...

Page 15: ...Part No 15 097 52 7 8 DECLARATION OF CONFORMITY FOR F STOP PG 1 EMV ROHS DE 2014 09 15 LPLW LQGLFDWRU WHVW GHYLFH 7 SH 6WRS 3...

Page 16: ...und Armaturen Gesellschaft mbH Co KG Obernbreiter Stra e 2 16 97340 Marktbreit Germany Tel 49 9332 404 0 Fax 49 9332 404 43 E Mail info gok online de Internet www gok online de 8 8 Part No 15 097 52...

Reviews: