Caramatic DriveOne
22 / 36
START-UP
Apply
the sticker
accompanying the
product to
a v
i
sible area of the safety
gas pressure regula
tion
device.
1
. Start the system by slowly opening
the gas supply while the shut-off
fitting of the connected consumption
equipment remains closed. Observe
the assembly and operating manual
of the connected consumption
equipment!
2
. By pushing in the blue excess flow
device SBS push button, hold this
down for 5 seconds (e.g. Caramatic
ConnectDrive – not included).
Activate the crash sensor the first time
you start the system:
3
. By pushing the green crash sensor
push button, hold this down for 5
seconds until the sphere is in position
and rolling sounds can no longer be
heard.
OPERATION
•
Use this product only when you have carefully read the assembly and operating
manual.
•
For your own safety, observe all the safety messages in this assembly and operating
manual.
•
Please also consider the safety of others.
TROUBLESHOOTING
Fault cause
Action
Gas smell
Leaking LPG is extremely
flammable.
Can cause explosions.
Close the gas supply.
Do not use any electric switches.
Do not use a phone in the building.
Ventilate rooms well.
Shut down the LPG system.
Contact a specialised company.
No gas flow.
Open the gas cylinder valve or the shut-off fittings.
Pressure regulator is defective, replace.
Activation of the crash sensor see START-UP.
Abnormal flame pattern of
non-adjustable pressure
regulator
Compare the nominal outlet pressure with the nominal
connection pressure:
if they do not correspond, replace the pressure regulator
or the gas appliance.
Safety two stages regulator
S2SR reacted.
Allow short bursts of gas to escape from the gas
equipment to achieve pressure compensation.
If no pressure compensation is achieved, replace the