Double
‐
stage tank regulator PS 25 bar
15 / 16
RESTORATION
If the actions described in TROUBLESHOOTING do not lead to a proper restart and if there is
no dimensioning problem, the product must be sent to the manufacturer to be checked. Our
warranty does not apply in cases of unauthorised interference.
SHUT-DOWN
Close the gas supply and then the shut-off fittings of the connected loads. When the LPG
system is not in use, all valves must remain closed.
Close all free connections in the feed lines of the LPG system tightly with a suitable cap to
prevent gas from flowing out.
DISPOSAL
To protect the environment, our products may not be disposed of along with
household waste.
The product must be disposed of via a local collection station or a recycling station.
TECHNICAL DATA
Inlet pressure p
1 to 16 bar
Outlet pressure p
d
29, 37, 50 or 67mbar
Nominal flow rate M
g
max. 20kg/h
Type BHK 052
max. 10kg/h
Type BHK 052B
max. 6kg/h
Type BHK/K and Type BHK/K-EFV
Maximum admissible pressure PS 25bar
Ambient temperature
-20°C to +50°C
Housing material
ZP0410
Response pressure according
to DIN 4811
OPSO: 120mbar
PRV: 150mbar
Response pressure according
to EN 16129
OPSO: 120mbar (optional)
PRV: min. 20%
˃
p
o
to max. 150mbar
Response pressure UPSO
according to EN 16129
pd 29mbar
pd 37mbar
pd 50mbar
pd 67mbar
22mbar
27mbar
42,5mbar
55mbar
Maximum permitted pressure
drop in installed piping
∆P2 for p
d
29mbar, p
d
37mbar
∆P5 for p
d
37mbar, p
d
50mbar, p
d
67mbar
∆P =
Maximum permitted pressure drop in installed piping. Refer to the nameplate of
the pressure regulator for more technical data and special settings!