DESIGN

 

The GS Pro-Fi 3 consists of the following individual assemblies: 

  Deaeration device within the deaerator cover and the housing 

  Deaerator screw 

 at deaerator cover 

,

 only used during start-up 

  Filter 

 inside the filter cover 

,

 filter elements consisting of any of the following materials: felt, sintered 

plastic, stainless steel, easy-change filter, or micro-filter 

  Filter cover and filter are available either in standard or in long version (with the exception of easy-change 

filter and micro-filter) 

  Check valve in the input port 

 

  Quick-acting valve 

 integrated in the housing 

  Fixing panel 

 for wall mounting in both installation directions 

  Connections 

, and 

 for mounting of pipe or hose lines, depending on the design 

OPERATING 
MEDIA 

Kerosene C2 and Gas oil D 

acc. to BS 2869 

Kerosene C2 and Gas oil D with max. 30 % FAME 

acc. to EN 14213 or EN 14214 

FAME 

acc. to EN 14213 or EN 14214 

Bio-Liquids for combustion purposes 

acc. to OPS 24 

Diesel 

acc. to EN 590 

CONNECTIONS 

Connection

 

Dimension

 

according to standard

 

 

Manometer 
blindscrew 

Female thread G 1/8 with O-ring 

EN ISO 228-1 

 

Tank line 
(tank side)

 

Female thread G 3/8

 

EN ISO 228-1

 

Cutting ring connection RVS 6 (RVS 8, RVS 10)

 

EN ISO 8434-1

 

GOK universal connection fittings UA 6/8/10 mm 
Screwed clamping ring connection, brass

 

Initial testing of construction 
products by a notified body (ÜHP) 

 

Burner flow line

 

Female thread G 3/8 or 

male thread G 3/8 A with A-KN (60° inside cone)

 

EN ISO 228-1 
prEN 12514-4:2009

 

 

Burner return line 

LABELING 

The GS Pro-Fi 3 bears the following labels:

 

Label

 

Significance

 

Explanation

 

 

Manufacturer’s sign

 

GOK Regler- und Armaturen-Gesellschaft mbH & Co. KG

 

 

Tank line 

 

Connection of the pipeline on container side, flow direction indicated

 

Burner flow line 

 

Connection for pipe/hose line, flow direction indicated

 

             

Burner return line 

 

Connection for pipe/hose line, flow direction indicated

 

 

The label on the upper filter cover shows the flow diagram and the version of the GS Pro-Fi 3 
with the stated article number. 
The Ü sign is the evidence of initial testing of construction products by a notified body (ÜHP) 
pursuant to Construction Regulation List A Part 1. 
Test report no. 

S 51 2005 Z2

 by TÜV Immissionsschutz und Energiesysteme GmbH 

DIN CERTCO Certificate of Conformity, register number 

2Y115/05

 with EN 12514-2:2000 

Certification Program Oil Supply Systems for Oil Burners

 

 

PA/4186/05 - Test report quality label “PROOFED BARRIER“ by Fraunhofer-Institut 
Verfahrenstechnik und Verpackung of 2005-12-15 / see Annex 2

 

 

This device meets the requirements of the OFTEC OIL FIRING PRODUCT STANDARD

 

OPS 23 :11-2007 / see Annex 1

 

Summary of Contents for 13512 Series

Page 1: ...n system of the 3 generation It is designed as a closed system Geschlossenes System GS It corresponds to the requirements of EN 12514 2 2000 the code of practice for oil firing according to BS 5410 1...

Page 2: ...VS 6 RVS 8 RVS 10 EN ISO 8434 1 GOK universal connection fittings UA 6 8 10 mm Screwed clamping ring connection brass Initial testing of construction products by a notified body HP Burner flow line Fe...

Page 3: ...The bleeder line dimensions should provide for a mean fuel flow rate of 0 2 to 0 5 m s If the diameter of the pipes is too large low flow rates occur which can result in formation of undesirable gas...

Page 4: ...of a screwed connection with brass or steel cutting ring for your information Component Connection via Explanations GS Pro Fi 3 Connecting branch in RVS 6 8 10 or 12 optionally available as factory mo...

Page 5: ...at the deaeration screw by means of the enclosed adapter Art no 13610 60 We recommend continuing the suction process until the upper cover is filled with oil as well After that re tighten the deaerat...

Page 6: ...deaerator cover can only be replaced as a complete assembly i e together with deaerator screw If the system has been submerged any outside soiling of the filter should be cleaned off with a commercial...

Page 7: ...perating medium and environment Maximum permissible pressure PS 6 bar with plastic cover PS 10 bar with easy change filter element PS 16 bar with metal cover Material of housing Metal ZP0410 Normal fl...

Page 8: ...ersion 10 2012 Page 8 GOK Regler und Armaturen Gesellschaft mbH Co KG Obernbreiter Stra e 2 16 D 97 340 Marktbreit Phone 49 9332 404 0 Fax 49 9332 404 43 E mail info gok online de Internet www gok onl...

Reviews: