- 13 -
Doku VARIOMAX_engl_06 12
June. 2012
Goch GmbH & Co. KG
7. Troubleshooting
Symptom
Possible cause
No spark, no ignition.
No power to control unit
Controller defective
Spark electrode defective
Ignition wire defective or loose
Heater sparks but will not light.
No gas supply
Combination valve will not open
Check nozzle pressure
Nozzle is dirty or clogged
Just in case of two-stage heaters:
High-low valve is stuck
High.low solenoid defective
Heater lights but locks out after
about 30 sec.
Reverse polarity on electric supply
Fame monitoring sensor (ionization
electrode) defective
Flame sensor wire defective or loose
Control unit defective
Heater lights for several minutes but
then shuts down. After repeated
ignition it remains in operation.
Fame monitoring sensor (ionization
electrode) damaged
Heater back-fires.
Ceramic tiles damaged
Sealing of the ceramic tile to the burner
body damaged