Setting the Transmitter
Test Flash
5. The settings on the transmitter end will synchronize to the receiver end at the same
time.
1. Press the <TEST> Trigger Button to see the
whether flash will fire normally or not.
2. Fully press the <TEST> Trigger Button, and
the Status Indicator Lamp turns red and the
flash on the receive end can be triggered.
3. Use the transmitter to control camera to
focus or shoot, and the transmitter is
connecting to the camera (do not connect to
the flash) now.
4. In the standby mode, press the TEST
Button can wake up the receiver.
Setting GR Grouping Mode
Note: GR mode can only be used normally when attaching to the CANON EOS cameras that
issued after 2012. In the GR mode, multi flash cannot be set.
1. Press the <MODE> Mode Button until
Gr
icon is displayed, which shows that GR
grouping mode has been set.
2. To cancel GR grouping mode, press the
<MODE> Button again until the
Gr
icon
disappeared.
- 38 -
- 37 -
Modeling Lamp Control
Double-click the <CH/OK> Button to power ON/OFF the modeling lamp.
CH
Gr
Setting the Transmitter
Automatically Enter Power Saving Mode
1. The flash trigger will go into standby mode after the transmitter enter sleep mode, and
the displays on the LCD panel will disappear.
2. Press any of the button (<TEST> fully pressed/<CH/OK>/<GR>/<MODE>) can wake
up the flash trigger. If the transmitter is attached to the CANON EOS camera, half
press the shutter can also wake up the system.
3. If the transmitter is set to single contact mode( is
displayed), the system will not
enter power saving mode.
The following table lists the available and unavailable custom functions of this flash. The
icon“√”indicates the flash custom function is supported but “0”indicates the custom
function is not supported.
Settings and Description
No delay
Synchronization delay N*100 us
(synchronization delay icon
is displayed.)
OFF
ON(The single contact mode set icon
is displayed.)
Setting Signs
00
1~100
--
on
Functions
Synchronization
delay setting
Single contact
mode
Custom
Functions No.
C.Fn-00
C.Fn-01
Application
√
√